Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.00.docx, Page 17 of 28
Figure 5.7
– Connection to the terminal box
Attention!
Introduce the foiling up to about 15 mm close to the terminals, in order
to prevent alien crosstalk. Make sure that the foiling cannot cause any
short circuit of the data pairs!
Attention!
Bring the twisted pair composite up to about 10 mm close to the ter-
minals, in order to ensure interference immunity.
Attention!
Use only terminals approved by SAMCON.
Attention!
Finally, check your network installation with a Class-D Link Test.
Note:
If the camera is equipped with a camera cooling system (SAMCON cool.Jacket for model
key type X.HH), the wiring is executed via the cable SKD05-HT.
An appropriate water
supply has to be provided by the customer.
PoE(+) 802.3af
100 BASE
TX
Ethernet