background image

 
 
 

 
 
 

Doc.-ID: 140721-PT08BAU-SS-Ex Installation Manual rev.03 (1st Supplement), page 51 of 52 

 
 
 

Summary of Contents for ExCam Series T08

Page 1: ...ExCam Series T08 Installation Manual...

Page 2: ...eral Safety Instructions 11 5 Application 13 6 Transportation and Storage 14 7 Installation 14 7 1 1 Type T08 VAx x x x 15 7 1 2 Type T08 TNXCD 16 7 2 Opening and closing of the unit 17 7 2 1 Type T08...

Page 3: ...sealing type T08 TNXCD 23 History of revisions Product T08 ExCam Series Title Ex Installation Manual of the ExCam Series Doc Id 140721 PT08BAU SS Ex Installation Manual rev 00 doc Author Steffen Seib...

Page 4: ...used in ex zones 1 2 21 22 including the explo sion groups IIC e g acetylene and IIIC conductive and flammable dusts The Ex d housings are available in different steel qualities due to which the housi...

Page 5: ...laration of Conformity ATEX Type Examination IECEx Certificate EAC Ex Certificate Manufacturer Declaration EN 60079 14 ExCam vario User Manual Datasheet ExCam niteZoom User Manual Datasheet ExCam IP13...

Page 6: ...ion Gas Ex d IIC T6 Gb or Ex d IIC T5 Gb or Ex d IIB T6 Gb or Ex d IIB T5 Gb or Explosion protection Dust Ex tb IIIC T80 C Db IP68 or Ex tb IIIC T95 C Db IP68 Explosion protection Mining Ex d I Mb 3 1...

Page 7: ...9 18 2009 IEC 60079 28 2006 ISH1 2014 EN 60079 28 2007 Beiblatt 1 2014 09 GOST R IEC 60079 0 2011 GOST IEC 60079 1 2011 Conformity of standards Dust IEC 60079 31 2008 EN 60079 31 2009 GOST R IEC 60079...

Page 8: ...n concept and are obligatory Type T08 VA T08 T6 85 C 5K T5 100 C 15K TAMB TAMB 40 C 50 C 60 C 70 C 40 C 50 C 60 C 70 C 75 C VA1 1 x x 17 4 W 13 0 W 8 7 W 4 3 W 19 6 W 15 2 W 10 9 W 6 5 W 4 3 W VA1 1 x...

Page 9: ...to the individual operating manual of the T08 series e g ExCam IP135x PM1145 L IPQ6045 etc Protection level EN 60529 IEC 529 T08 VAx x x x IP68 test condition 24 h 3 m water column at 5 C An additiona...

Page 10: ...2 2 AISI 316Ti Fitting for the flameproof gap cylinder according to DIN ISO 286 1 T08 VA1 x nominal diameter 57mm Tolerance 60 30 m 0 46 m Gap length L1 13 0 mm L2 16 2 mm T08 VA2 x nominal diameter 9...

Page 11: ...bH may be used for repairs Repairs concerning the explosion protection may only be carried out in accordance with the nationally applied regulations and by SAMCON Prozessleittechnik GmbH Attention Ext...

Page 12: ...BE OPENED IN HAZARD AREAS Note Depending on the zone classification it might be necessary to obtain a work permit clearance When adjusting the camera settings potentially explosive atmosphere must be...

Page 13: ...areas of zones 1 and 2 as well as zones 21 and 22 in accordance with EN 60079 10 The camera may only be used within the certified ignition protection type and temperature class Attention The instruct...

Page 14: ...operation of the camera Before installation check the camera for possible damages to the housing and cables Installation electrical connection and start up should only be carried out be qualified pers...

Page 15: ...o the housing is in tended for this purpose and disposes of a 6 5 mm or an 8 5 mm drilling The wall mount bracket is available in different dimensions and may be installed in any position which is all...

Page 16: ...mera at the wall the six M8x1 25 threaded holes located at the cover flange and correspondingly at the wall mount bracket with L profile accessories can be used The installation at a ceiling can be re...

Page 17: ...camera modules or lenses WARNING MAY NOT BE OPENED IN HAZARD AREAS NOTE Depending on classification of the hazard area a work per mit clearance has to be obtained Prevent explosive atmospheres while a...

Page 18: ...ocket 10mm 1 4404 A4 70 DIN912 ISO4762 o T08 VA1 x K2 x 5x M4 0 7 cylinder head screw hexagon socket 25mm 1 4404 A4 70 DIN912 ISO4762 o T08 VA2 x K1 x 8x M4 0 7 cylinder head screw hexagon socket 12mm...

Page 19: ...optic temperature controller etc which are fixed to the cable and supply flange have to be treated very care fully to avoid damages Attention When removing the flange do not damage or pollute the Gylo...

Page 20: ...as to be reassembled according to the ho le pattern of the flange There is no restriction regarding the installation direction of the sealing If when closing the housing it is noted that the surface o...

Page 21: ...en the applicable user manual explicitly allows it For all other purposes the explosion proof housing may only be opened and closed by authorized personnel of the company SAMCON Prozessleittechnik Gmb...

Page 22: ...th hexa gon socket DIN 7991 at the flange component q v figure 10 8 Figure 10 8 Disassembly of the countersunk head screw type T08 TNXCD Counterclockwise unscrew the cover flange with fine thread M188...

Page 23: ...thing contact at the cylindrical fit as it disposes of oleaginous fit ting compound MOLYKOTE P 40 to protect the surface for frictional corrosion and mechanical strain Attention Installed components c...

Page 24: ...housing IP protection level Attention Tighten the flange by hand there is no tightening torque defined Attention Beware not to damage the surface of bore hole and shaft fit at the flame proof gap pre...

Page 25: ...has to be fused externally If the camera will have to be commissioned at temperatures below 0 C it has to make sure that the camera is turned on time delayed Before the camera is allowed to be used t...

Page 26: ...ied out when the need for them is recognised during maintenance 9 Reparation Reparations must only be carried out with original parts of SAMCON Prozessleittechnik GmbH Damaged pressure resistant casin...

Page 27: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 27 of 52 11 Certificates 11 1 EC declaration of conformity...

Page 28: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 28 of 52 11 2 Manufacturer s declaration concerning the cable and cable entry points...

Page 29: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 29 of 52 11 3 EC Type Examination Certificate...

Page 30: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 30 of 52...

Page 31: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 31 of 52...

Page 32: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 32 of 52...

Page 33: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 33 of 52...

Page 34: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 34 of 52...

Page 35: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 35 of 52...

Page 36: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 36 of 52 11 4 IECEx Certificate of Conformity...

Page 37: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 37 of 52...

Page 38: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 38 of 52...

Page 39: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 39 of 52...

Page 40: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 40 of 52...

Page 41: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 41 of 52...

Page 42: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 42 of 52...

Page 43: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 43 of 52...

Page 44: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 44 of 52 11 5 EAC Ex Certification...

Page 45: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 45 of 52...

Page 46: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 46 of 52...

Page 47: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 47 of 52...

Page 48: ...rev 03 1st Supplement page 48 of 52 12 Drawings Equipment drawings can be found in the individual datasheets DXF files 3D models drawings of accessories can be found at www samcon eu For additional in...

Page 49: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 49 of 52 13 Notes...

Page 50: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 50 of 52...

Page 51: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 51 of 52...

Page 52: ...Doc ID 140721 PT08BAU SS Ex Installation Manual rev 03 1st Supplement page 52 of 52 Schillerstrasse 17 35102 Lohra Altenvers www samcon eu info samcon eu fon 49 6426 9231 0 fax 31...

Reviews: