20
ALPS / OLIMP
SNOW PLOW
OPERATOR’S MANUAL
Fig. 15.
Placement of N-176 decal
–
mounting plow on vehicle
5.2.
Plow control
ATTENTION:
Prior to mounting plow make sure that polarity of aggregated machine is the
same as driver's (
). Wrong polarity will cause damage to the driver.
Fig. 16.
Polarity of driver's plug
Once hydraulics and power plug are connected, move control panel along with cable to tractor's cabin
and connect the plug to lighter's connector 12V (
). In order to lift/lower the plow, use control
lever for tractor's front 3-point linkage.
ATTENTION!
The control panel should be connected to the machine in the following order:
1.
connect the control panel so that the control system is completely electrically
connected,
2.
connect the 7-pin connector in the plow,
3.
connect the power plug (lighter connector) in the tractor.
Reverse connecting sequence is not permitted and, as a result, may damage the
control panel.
When disconnecting, do the opposite, first disconnect the power supply and then
the panel!
ATTENTION:
After mounting the plow check its functions:
- opening and closing of the left plow moldboard,
- opening and closing of the right plow moldboard,
- lifting and lowering of the plow on the TPH
.
+
̶