Sirius 800 Series User Manual
Nucleus 2450 Router Controller Card
Nucleus Router Control Modules 14.5
Iss 5 Rev 7
Page 281
© 2017 SAM
14.5.5.2
Modify an ini File Using Copy
1.
Ensure the Nucleus Controller card to be removed is idle:
2.
If the Nucleus controller to be removed is Active (see Table 79) press the reset button
on it (see Figure 181 on page 271) and the Active and Idle Nucleus controllers will
swap over.
3.
Remove the Idle Nucleus controller card.
4.
Remove the Compact Flash memory card from the Nucleus controller and insert it into
a card reader.
5.
Plug the card reader into your computer and view the files on the memory card.
6.
If no changes are required the ini file can simply be opened with a text editor, such as
Microsoft Notepad, viewed and then closed again without saving.
7.
Open the ini file to be modified using a text editor such as Microsoft Notepad.
8.
Make any changes required to the ini file and
Save
the modified file to the Compact
Flash card.
9.
Eject the Compact flash card from your computer and remove the Compact flash
card.
10. Insert the Compact flash card back in the Nucleus controller.
11. Replace the Nucleus controller in the router and it will reboot.
12. If changes are also required on the second Nucleus controller (if it is fitted) repeat the
process so that both controllers contain the modified ini file.
14.5.6 Nucleus 2450: Changing the IP Address
The Nucleus controller IP address and network connection information is stored in the
Network.ini file on the Compact Flash card on the Nucleus controller, see section 14.5.4 for
details of the contents of the Network.ini file.
The Network.ini can be opened by using a text editor such as Microsoft Notepad at which
point it can be viewed, backed up and modified as required. If the IP address is known then
this can be done remotely via FTP software or if it is not known then the Compact Flash card
can be removed from the controller and read locally on a computer. See section 14.5.5 for
details on both methods.
Note:
If the router is only fitted with a single controller the controller will be Active rather than Idle.
Nucleus
Controller
LED Number/Color
LED Number/Color
2450
LED D4
:
Idle = Purple
Active = Blue
LED D16
:
Idle = Flashing Red
Active = Flashing Green
Table 79
Nucleus 2450 Active/Idle LED Status
Note:
Before making any changes backup the ini file to be modified to the computer. It is a good
idea to modify the backup filename with a date in case it is required at a future date.
Note:
If the controller IP address is changed remember to use the new IP address to connecting
to it.