SALVIS AG
CH-4665 Oftringen www.salvis.ch
Salvis Fresh & Smart 1100
5
Operation
5.1
General notes on safety
Attention! Rollover and tipover danger!
When transporting the Fresh & Smart across uneven terrain, you can lose control of it. Do not
release or let the module roll alone during transport.
Attention! Danger of crushing!
When changing the location, make sure that no body parts get caught between the Fresh & Smart
and surrounding object, specifically when moving the appliance into a niche. After parking the
appliance at the work location, the wheels must be locked using the stops to prevent it from rolling
away.
5.2
Starting up the Fresh & Smart
The suction module was checked for its functionality after its manufacture. Prior to the initial start-up, please
ensure that there is no packaging residue or other objects inside the housing or the lateral air channels and
that the filters and grease traps have been inserted in the correct positions.
The Fresh & Smart must never be used without correctly inserted and correctly placed filter
components or without the grease trap.
The suction module is turned on by connecting the connecting cable to a properly installed and fused 400V
CEE receptacle. As soon as this connection is made, the indicator lamp (
1
) will illuminate green. From this
point on, the receptacles inside the operating panel will be supplied with power.
In order to start up the air circulation system, activate the switch for the circulation system on the left or
right. If both sides of the air circulation system are turned on, the expelled moisture, which is contaminated
with grease or odours, is routed into the suction channel and the filter system in three directions (left, right
and rear).
We recommended letting the ventilation system run an extra 10 minutes after the cooking process,
so that the rising expelled moisture caused by the residual heat can dissipate into the environment.
Before opening the revision panel of the Fresh & Smart, both power switches for the air circulation
system must be switched off. Otherwise, the ventilator of the exhaust system will pose a danger of
injuries.
Operating panel (EURO-version):
1) 2x ON/OFF switch for air circulation version
1
2) 2x Indicator lamp for air circulation system
2
3) 2x 230 V plugs Schuko
3
4) 2x 400 V plugs CEE
4
Operating panel (CH-version):
1) 2x ON/OFF switch for air circulation version
1
2) 2x Indicator lamp for air circulation system
2
3) 2x 230 V plugs type 12
3
4) 2x 400 V plugs type 25
4
Page 9