33
1
/
2
"
(85.09)
8
7
/
8
"
(22.56)
33
1
/
2
"
(85.09)
8
7
/
8
"
(22.56)
Fabricator Instructions
Attaching Disposer
STOP!
If you have any questions about this installation call 1-888-SALVAJOR for installation advice.
1.
Carefully remove the top housing assembly by removing the eight bolts
making sure not to damage the center gasket.
2.
Apply lubricant to the rubber collar on the top housing and the beaded
collar on the transition of the TroughVeyor.
3.
Install the top housing assembly up onto the beaded collar and tighten the
clamp so the top housing assembly can not be pulled down over the bead.
Cut the rubber baffles out of the hycar adaptor to reduce bridging
of food waste.
4.
Measure distance from the bottom of the top housing to floor.
5.
Turn the disposer on its side and install the leg support on the bottom of
the disposer and adjust the leg extension so the disposer will stand
approximately 1/2” below the bottom of the top housing.
6.
Carefully balancing the disposer on the leg support, place it under the top
housing, aligning the ears on the shredder ring with the locking tabs of
the top housing.
7.
Slide the center gasket into place. Insert the top housing bolts through
holes in the top housing and into the disposer body housing. As you the
tighten bolts, the disposer will pull up securely to the top housing. Extend
the leg extension securely on the floor, and tighten set screws.
8.
If disposer drain orientation is incorrect loosen top clamp and rotate
disposer to correct location.
NOTE:
It is important that the leg fit tightly between the disposer and the floor.
1
1
/
2
" FEMALE
THREAD to 1
1
/
2
"
SWEAT FITTING
ADAPTER (NF)
1
1
/
2
" UNION (NF)
#TVD3 GASKET
#TVD2 LOCKNUT
TROUGH SECTION
3”
MIN.
DIFFUSER #980061
11
1
/
2
" (29.21)
7
3
/
8
" (18.75)
8
3
/
8
" (21.27)
8
7
/
8
" (22.54)
The open end of the fabricated
trough should include a flange
to match the flange on the
TroughVeyor. The two flanges
are to be butted together and
securely welded.
Weld the TroughVeyor into the table using the dimensions above for the table cutout.
A 2” diameter hole is required at the closed end of the trough for the factory furnished water diffuser which ensures a proper
water flow pattern down the trough. Center the 2” diameter hole 1
1
/
4
” from the bottom of the trough. A 1
1
/
2
” union can be used
instead of the 1
1
/
2
” sweat fitting when the plumbing will need to be disconnected. The closed end of the fabricated trough
should have a minimum depth of 3” and a fall of at least 3/32” per running foot so that there will be adequate drainage
to the TroughVeyor machine.
LEFT HAND - Model
TVL
RIGHT HAND - Model
TVR
TROUGHVEYOR FLANGE
DIMENSIONS
DIFFUSER
INSTALLATION DETAIL
See TroughVeyor
Flange
Dimensions
3