Specification:  

 Package Content:  

Protocol: Z-Wave™ (ZS6101N)   1pc   ZS 6101 smoke detector  

Frequency Range:  

1pc   Bracket Holder  

868.42MHz (ZS6101EU)  

2pcs  Plastic Anchor & Screws  

908.42MHz (ZS6101US)  

1pc   CR123A Lithium Battery  

921.42MHz (ZS6101AU)  

1pc  

  

Installation & Operation 
manual  

Operating Range  

 

Up to 100 feet line of sight  

Operating Temp.  

  
  

-10°C~ 50°C (14°F ~122°F)  

Battery  

 

Panasonic CR123A * 1PC  

  

Note: If you are installing the entire Z-Wave TM system for the first time, 

please refer to the installation guide of Z-Wave TM Interface Controller before 
installing ZS6101.   

 For “Inclusion” in (adding to): Put the Z-Wave TM Interface Controller into  
“inclusion” mode, and following its instruction to add the ZS6101 to your 

controller. To get in the “inclusion” mode, the distance between sensor and 
controller is suggested to be in one meter. Press the program switch of 
ZS6101 for 1 second at least to be included.  

For “Exclusion” from (removing from) a network: Put the Z-Wave TM Interface 

Controller into “exclusion” mode, and following its instruction to delete the 
ZS6101 to your controller. Press the program switch of ZS6101 once to be 
excluded. Please note: The LED on the ZS6101 will flash (red) continuously in 
Exclusion mode.  

For “Awake” mode : it is to leave the “Sleep” mode by pressing the program 

switch for 1 second at least to allow the Z-Wave TM Interface Controller to do 
“inclusion”, “exclusion”, “Association” and to reply and receive the commands 
from controller. It will take about 5 seconds and the red LED light on for 
awaking the system. LED light will be off after setting.  

Reviews: