Introduction
The RXBC5V boiler module 868MHz is a receiver with 5V DC
to control ON/OFF of Boiler or other heat system via the RF
signal transmitted from the thermostat.
Product Compliance
This product complies with the essential requirements
and other relevant provisions of Directives (RED)
2014/53/EU and 2011/65/EU. The full text of the EU
Declaration of Conformity is available at the following
internet address: www.salus-controls.com.
Safety Information
Use in accordance with the regulations. Indoor use
only. Keep your device completely dry. Disconnect your
device before cleaning it with a dry cloth.
868MHz-868.8MHz; <13dBm
Terminal connections
The RXBC5V is compatible with the following
SALUS products
RT310TX
RT510TX
iT500BM
RT310iTX
ERT20TX
Compatibility
Terminal Identifier Description
1
DC +
DC power supply (+)
2
DC -
DC power supply (-)
3
COM
Common input
4
NO
Normal Open
5
NC
Normal Closed
Installation
Switch Position
1
1
2
3
2
3
The boiler receiver is off.
AUTO. RX will automatically
receive the RF signal from
your compatible SALUS
device and controls relay
output.
Manual mode - Manual Override (Note this mode
will run your boiler continuously)
1. Ensure boiler is isolated and switched off.
2. Pull down control panel cover.
3. Remove existing mechanical timer and unscrew
from plate.
4. Reverse the procedure to install the RXBC5V.
Note:
When removing blanking plate also
remove visible thermostat link plug do not
remove any internal link.