![Salus PCSol 201 Installation And Operation Manual Download Page 50](http://html1.mh-extra.com/html/salus/pcsol-201/pcsol-201_installation-and-operation-manual_3644550050.webp)
50
19.1.
System Options\Settings
The
following
settings
are
available
depending on scheme and version:
Parameter
Scheme
A B C D E F G H I
J K L M N O
dTonDHW
X X X X X X X X
X X X X
X
dToffDHW
X X X X X X X X
X X X X
X
dTonPOOL
X
X
X X
dToffPOOL
X
X
X X
TCOLmin
X X X X X X X X X X X X X X X
TCOLcr
X X X X X X X X X X X X X X X
TCOLmax
X X X X X X X X X X X X X X X
TDHWmax
X X X X X X X X
X X X X X X
Pmin
X X X X X X X X X X X X X X X
tP
X X X X X X X X X X X X X X X
HP1
X X X X X X X X X X X X X X X
HP2
X X X X X X X X X X X
X X X
tVALVE
X
tDLY
X
X
X
X
TCOmin
X
dTP2
X
Settings description
dTonDHW -
temperature difference between
T1
(
T3
in scheme
H
)
and T2
(
T3
in scheme
E
)
that will the collector pump
P1
or
P2
at
100% capacity.
dToffDHW -
temperature difference between
T1
(
T3
in scheme
H
)
and T2
(
T3
in scheme
E
),
at which the pump will work with minimal
capacity
Pmin
.
Below this value, the
collector pump is stopped. It will be restated
when
dTonDHW
value is reached
.
dTonPOOL
–
in schemes with pool system,
temperature difference between
T1
and
T3
(for scheme
F
) and
T1 and T2
(for scheme
I
), which starts
P1
pump at 100% capacity.
dToffPOOL -
temperature difference between
T1
and
T3
(for scheme
F
) and
T1 and
T2
(for
scheme
I
), at which the pump will work with
minimal capacity
Pmin.
Below this value, the
collector pump is stopped. It will be restated
when
dTonPOOL
value is reached.
TCOLmin
- minimal collector temperature, which
must be reached to allow reservoir loading. If
the collector temperature has not reached
this setting value, despite that loading
conditions are met (resulting e.g. from
reaching
dTon
) the controller would not start
the collector pump.
The collector pump will be started only below
dToffDHW
or
dToffPOOL
(depending on
scheme).
TCOLcr
–
collector
critical
temperature.
Temperature which regardless of reaching
reservoir preset (
TsDHW
) or pool preset
(
TsPOOL
) will start the collector pump at
100% capacity in order to discharge heat
from the collector. It will be stopped when
the collector temperature drops below
TCOLcr-HPx
(where x means the number of
collector pump:
1
or
2
). If
AlarmTCOLcr
setting has
YES
value
,
the unit displays
alarm
on
exceeding
critical
collector
temperature. This alarm allows starting
collector pump, only when the system with
DHW
reservoir is not in condition of
exceeded reservoir maximal temperature
TDHWmax
alarm
.
TCOLmax
–
reaching this collector temperature
will stop the collector pump. The controller
reports alarm. The collector pump may be
started only when the collector temperature
drops below the temperature difference
TCOLmax-HPx
.
The controller dynamically limits minimal
value of
TCOLmax
setting and maximal
value of
TCOLcr
setting,
so that set values
give
interval
between
TCOLcr
and
TCOLmax
not lesser than 30°C. This
protects from impulse increase of the
collector temperature when the collector
pump is started, after
TCOLcr
is reached.
To set higher
TCOLcr
than allowed by the
controller, increase
TCOLmax
value, so
that the interval condition of 30°C is
maintained.
TDHWmax
-
DHW
reservoir
maximal
temperature that stops collector pump and
disables further loading of the reservoir.
Alarm on exceeding DHW reservoir maximum
temperature is displayed. This alarm has
higher priority than alarm on
TCOLcr
and
despite the alarm on collector critical
temperature; the controller will disable
starting the collector pump for the reservoir.
Alarm will be stopped and the pump start
released, when the reservoir temperature
drops below
TDHWmax-HPx
.
Pmin
–
minimal capacity of the collector pump
reached if the difference between collector
and
reservoir
temperatures
drops
to
dToffDHW
or
dToffPOOL
value (depending
on scheme).