17.2.
Solar Application scheme B
Loading of DHW reservoir from solar panel with additional function of extra heating with a heater,
when the solar panel stops supplying energy and with control of
DHW
circuit with circulation pump.
In this layout, it is required to connect
T3
sensor and it must be installed in the reservoir over a
heater. If
T3
is disconnected from the controller or damaged, it will disable reservoir extra heating
function. How to connect
H
output to a heater via a relay is presented in details in section
Fig. 17.2 Application scheme B
Installation recommendations
1.
For the controller to count heat output, install additional CT6 sensor on the outlet of lower pipe coil
from DHW container and connect to
T4
input. The sensor must be installed possibly near the
connector pipe.
2.
T3
sensor is used for controlling additional heat source (
H
output). Disconnection of the sensor will
disable
H
output and the algorithm of the container loading from collector will work normally.
3.
Connect the heater to the
H
output via the relay. It is necessary to use a relay type 6VDC
RM85-
2021-35-1006
.
Mains 230~
S
u
p
p
ly
L
S
u
p
p
ly
N
Pu
m
p
P1
[N
]
S
en
so
r
T
1
[+
]
S
en
so
r
T
1
[
-]
S
en
so
r
T
2
[+
]
S
en
so
r
T
2
[
-]
S
en
so
r
T
3
[+
]
S
en
so
r
T
3
[
-]
S
en
so
r
T
4
[+
]
S
en
so
r
T
4
[
-]
Pu
m
p
P1
[L
]
Pu
m
p
P2
[L
]
Pu
m
p
P2
[N
]
Ou
tp
u
t
H
[+
]
Ou
tp
u
t
H
[
-]