Salus KL08RF User Manual Download Page 1

ZigBee network wireless wiring centre (8 zones), 

230 V AC
Model: KL08RF

Manual

Introduction

1. Fuse

Wiring centre description

2. Power Supply

3. Thermostat grouping status

4. Network Status diode

5. Pair button

6. Reset button

RX10RF (optional)

7. Delay jumper

8. INT/EXT antenna jumper

9. NC/NO actuators jumper

Technical Information

Product Compliance

Safety Information

This product complies with the essential requirements and other relevant provisions of Directives: EMC 

2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. The full text of the EU Declaration 

of Conformity is available at the following internet address: www.saluslegal.com.

Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect your device 

before cleaning it with a dry cloth. This accessory must be fitted by a competent person, and installation must 

comply with the guidance, standards and regulations applicable to the city, country or state where the product 

is installed. Failure to comply with the relevant standards could lead to prosecution.

This function is only available in Offline mode (together with CO10RF coordinator)  

- it means MASTER thermostats will affect to SLAVE thermostats within specific group, 

which is possible only when thermostats are paired with one KL08RF wiring centre 

(op KL04RF) and have been assigned to gr. 1 or gr. 2.

How it works: 

If all thermostats of a given group will operate in automatic mode, then each of the thermostats 

in a given group will work in the same way as the MASTER of this group. For example, if the MASTER thermostat 

of Group 1 according to it’s programmed schedule maintains a comfort mode - all SLAVE type thermostats from 

Group 1 will also maintain the comfort mode (the temperature is set individually for every thermostat). Similarly, 

if the MASTER thermostat is set to Party or Holiday mode - SLAVE thermostats in his group will also work in 

these modes.

The mains fuse is located under the housing cover, at the main terminals and protects the wiring centre and 

devices powered by it. Use cartridge fuse-type  5 x 20 mm - nominal burn rate 12 A. To remove the fuse, lift 

the socket with a flat screwdriver and pull out the fuse.

- (LED is steady lit) - it means wiring centre is added to the ZigBee network and paired with CO10RF  

   or UGE600

- Checking the address of the wiring centre in the Zigbee network. To check the address of the  

   wiring centre in the ZigBee network (when using more than one) press the Pair button. 

   

The wiring centre number is indicated by the number of LEDs at the zones:

LED diode statuses:

Functions of the Pair button:

- The wiring centre reset 

   (this function is described in detail on the second page of the manual).

- It is used to refresh the data, after moving jumpers 7,8 or 9.

   The Reset button does not remove the wiring centre from the ZigBee network.

- (LED diode is blinking) - it means wiring centre is not connected to the network, but it is ready  

   for pairing with the coordinator (CO10RF) of the ZigBee network or the Internet gateway (UGE600)

Power supply for wiring centre is 230V ~, 50Hz.

Features of the installation:

• three-wire, with PE protective conductor,

• made in accordance with applicable regulations.

Additional, wireless device control module that can be used 

- for example - when we can’t use cable between the KL08RF 

wiring centre and the boiler.

Boiler off delay time.

There is an option to connect the 08RFA external antenna to the wiring centre.

If you use an additional antenna, place the jumper in the EXT position.

Select the type of the thermoelectric actuator connected to the wiring centre:
NC – actuator normally closed 

NO – actuator normally opened

L
N

The KL08RF wireless wiring centre is a part of the iT600RF system. In combination with the wireless thermostats 

from iT600RF series, KL08RF provides comfortable and reliable heating control. It is equipped with the control 

outputs for the pump and boiler and has been designed to work with NC or NO actuators. 

In Offline mode, communication with the wireless thermostats from iT600RF series must be done through  

the CO10RF co-ordinating unit, which is in the package together with the wiring centre. To work in Online mode 

(via the SALUS Smart Home app) KL08RF must be connected to the Internet gateway UGE600. In one ZigBee 

network (Online or Offline) up to 9 KL08RF wiring centres can be connected. KL08RF increases ZigBee network 

range.

1

2

5

7

11

12

17

13

14 15

16

8

9

10

6

3

4

1. 

Cartridge fuse 5 x 20 mm 12 A

2. 

Power Supply

3. 

Thermostat grouping status

4. 

Network Status diode

5. 

 Pair button

6. 

 Reset button

7.  

Delay jumper

8. 

  INT/EXT antenna jumper

9. 

NC/NO actuators jumper

10. 

ZigBee network coordinator

11. 

Terminals for actuators

12. 

Pump control output

13. 

Boiler control output

14. 

CO terminal

15.  

Dew point sensor input (humidistat)

16. 

 Serial connector for the KL04RF extension

17. 

 External antenna connector

15 sec

Jumper position change must be refreshed in the memory by pressing the Reset 

button (short press).

Note: 

Within one group there may be only one MASTER thermostat (programmable) and the rest 

must be SLAVE thermostats (non-programmable).

Note: 

Fuse replacement should be done when the wiring centre is disconnected from power supply 

230 V AC.

Note: 

Pump (Pump output) and boiler (Boiler output) always starts 3 minutes after 

receiving the heating signal from any thermostats paired with wiring centre. Pump 

stops after 3 minutes, when the last thermostat stops sending demand for heat, 

while the heat source (Boiler) will turn off after the time set with the jumper.

Jumper position change must be refreshed in the memory by pressing the Reset  

button (short press).

Jumper position change must be refreshed in the memory by pressing the Reset 

button (short press).

The grouping function is optional - thermostats do not have to be grouped, they can operate 

independently.

Address 9 is indicated by lighting up 8 LEDs of all the zones and the Network 

Status LED.

230 V AC

Adress 1

Adress 2

Adress 7

Power Supply

230 V AC 50 Hz

Max load

3 A

Inputs

CO terminal
Dew point sensor (humidistat)

Outputs

Pump control
Boiler control
Terminals for actuators

Radio frequency

ZigBee 2,4 GHz

Dimensions [mm]

355x83x67

Note: 

Don’t use CO10RF coordinator  

             with UGE600 simultaneously!

CO10RF

CO10RF

UGE600

I 2017

T: +44 (0) 1226 323961

E: [email protected]

Head Office:

SALUS Controls plc

SALUS House

Dodworth Business Park South, 

Whinby Road, Dodworth,

Barnsley S75 3SP, UK.

www.salus-controls.com

SALUS Controls is a member of the Computime Group.

Maintaining a policy of continuous product development SALUS Controls plc reserve the right  

to change specification, design and materials of products listed in this brochure without prior notice.

Summary of Contents for KL08RF

Page 1: ...ZigBee network wireless wiring centre 8 zones 230 V AC Model KL08RF Manual I 2017 ...

Page 2: ...2A 2 PowerSupply 3 Thermostatgroupingstatus 4 NetworkStatusdiode 5 Pairbutton 6 Resetbutton 7 Delayjumper 8 INT EXTantennajumper 9 NC NOactuatorsjumper 10 ZigBeenetworkcoordinator 11 Terminalsforactuators 12 Pumpcontroloutput 13 Boilercontroloutput 14 COterminal 15 Dewpointsensorinput humidistat 16 SerialconnectorfortheKL04RFextension 17 Externalantennaconnector Note Don t use CO10RF coordinator w...

Page 3: ...standardscouldleadtoprosecution TheKL08RFwirelesswiringcentreisapartoftheiT600RFsystem Incombinationwiththewirelessthermostats from iT600RF series KL08RF provides comfortable and reliable heating control It is equipped with the control outputsforthepumpandboilerandhasbeendesignedtoworkwithNCorNOactuators In Offline mode communication with the wireless thermostats from iT600RF series must be done t...

Page 4: ...ratureissetindividuallyforeverythermostat Similarly if the MASTER thermostat is set to Party or Holiday mode SLAVE thermostats in his group will also work in thesemodes Themainsfuseislocatedunderthehousingcover atthemainterminalsandprotectsthewiringcentreand devicespoweredbyit Usecartridgefuse type 5x20mm nominalburnrate12A Toremovethefuse lift the socket with a flat screwdriver and pull out the f...

Page 5: ...ssthePairbutton ThewiringcentrenumberisindicatedbythenumberofLEDsatthezones LEDdiodestatuses FunctionsofthePairbutton Thewiringcentrereset thisfunctionisdescribedindetailonthesecondpageofthemanual LEDdiodeisblinking itmeanswiringcentreisnotconnectedtothenetwork butitisready forpairingwiththecoordinator CO10RF oftheZigBeenetworkortheInternetgateway UGE600 15sec Address 9 is indicated by lighting up...

Page 6: ...allyclosed NO actuatornormallyopened Jumper position change must be refreshed in the memory by pressing the Reset button short press Note Pump Pumpoutput andboiler Boileroutput alwaysstarts3minutesafter receivingtheheatingsignalfromanythermostatspairedwithwiringcentre Pump stops after 3 minutes when the last thermostat stops sending demand for heat while the heat source Boiler will turn off after ...

Page 7: ...es off when the last thermostat stops sending heatdemand afterthetimesetontheDelayjumper L 230 V AC max 1A N 10 ZigBee network coordinator 11 Terminals for actuators Wires of the thermoelectric actuators should be plugged into the self locking connectors in the appropriate zones You can connect 3 actuators directly to one zone The current load of one zone is adapted to operate with up to 6 thermoe...

Page 8: ...sareproperlyconnected thenconnectthepowercordtothe230VACpower supply redLEDdiodewilllightup Afterfinishinginstallationmountthetopcover ofwiringcentre Shorting the contacts at the dew point sensor input too high humidity causes switchingoffallzonesinthewiringcentreandPumpcontroloutputs It is used for communication between the KL08RF wiring centre and the KL04RF extension module KL04RF extensionmodu...

Page 9: ...illblink Wiringcentrewillconnecttothenetworkautomatically TheNetworkStatusLEDwillturnsolidgreen 1 3 2 L N 230 V AC Scan for equipment OpentheZigBeenetwork ClosetheZigBeenetwork Online Online Offline Offline OR OR SALUS Smart Home 5sec 5sec 5sec Note Do not use CO10RF coordinator with UGE600 simultaneously 5sec Connect equipment ...

Page 10: ...hold the Pair button for 15 seconds G1 and G2 diodes will turn red andgoout ToidentifythewiringcentreintheZigBeenetwork followthestepsbelow In Online mode using the SALUS Smart Home app In Offline mode OR OR 1sec 15sec Note Ifyourestorethefactorysettingsofthewiringcentre allpaireddeviceswillberemovedfrom the ZigBee network you will have to synchronize them again 1sec 1sec 1sec ...

Page 11: ...uth Whinby Road Dodworth Barnsley S75 3SP UK www salus controls com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and materials of products listed in this brochure without prior notice ...