Two Central Heating Zones

The interface for the PC and the Smartphone app for the Two Central Heating Zones System Configuration:

Summary of Contents for iT500

Page 1: ......

Page 2: ...y other statutory obligations if you are in any doubt please contact the Salus Controls technical helpline This accessory must be fitted by a Competent person and installation must comply with the gui...

Page 3: ...ing Time On or Off 33 PAIRING THE iT500 AND iT300 WITH THE iT500RX 33 Pairing the iT500 Thermostat with the iT500RX Receiver 35 Pairing an iT300 with the iT500RX Receiver optional 37 Registering your...

Page 4: ...a completely new installation It is estimated that using a programmable thermostat can save up to 20 of the energy used by a traditional installation The equipment can be used without the Gateway unit...

Page 5: ...controller that is hardwired to your boiler pump and 3 way valve It allows for manual override in the event of failure of your iT500 Thermostat unit The iTG500 Gateway connects to your router and ena...

Page 6: ...ce the programmer and wired thermostat in a traditional domestic heating arrangement The equipment can be configured to control the following arrangements Heating only 1 zone Heating only 2 zones Heat...

Page 7: ...0 Thermostat Receiver are used to control two zone heating valves The temperature in Zone 2 is controlled by the addition of an iT300 Temperature Sensor Transmitter placed in the zone Boiler iT500TR i...

Page 8: ...talling an iT500 based control system with a single heating zone and hot water The iT500RX Receiver is hardwired to the heating and water system components The iT500 Thermostat is connected wirelessly...

Page 9: ...To control the system via your smartphone or a remote computer the system can optionally be connected to the Internet The iT500 Thermostat is connected to your existing broadband router using the iTG5...

Page 10: ...equipment Remove the cover from the existing programmable controller 2 Note down the wiring sequence and the cable colours connected to the terminals within the electrical box 3 Disconnect the wires f...

Page 11: ...X Receiver in the correct sequence See the wiring diagram later on in this section 6 Once the wiring has been completed position the iT500RX Receiver over the electrical box fixing holes Carefully pos...

Page 12: ...iT500 User Reference Manual 12 Installing in a New Heating Installation Install a new electrical box and connect the wires as detailed in the wiring diagrams below Volt Free Combination Boiler...

Page 13: ...iT500 User Reference Manual 13 230V Switching Combination Boiler...

Page 14: ...iT500 User Reference Manual 14 2 x CH Zones Volt Free Combination Boiler...

Page 15: ...iT500 User Reference Manual 15 230 V Switching S Plan 230V 230V 230V 230 V Switching S Plan BOILER 230 BOILER 230 Permanent 230V 2 C...

Page 16: ...iT500 User Reference Manual 16 2 x CH Zones 230 V Switching Combination Boiler...

Page 17: ...iT500 User Reference Manual 17 230 V Switching Y Plan...

Page 18: ...g bracket and clip the Thermostat to the wall as follows 1 Attach the wall mounting bracket to a suitable wall using the fittings supplied and the built in level Note For best results mount the iT500...

Page 19: ...iT500 User Reference Manual 19 Alternatively position the iT500 Thermostat on a flat surface using the stand provided Simply clip the clear stand supplied separately into the back of the unit...

Page 20: ...hermostat will go through the sequence of screens shown below and automatically try and pair by searching for the strongest signal from an iTG500 Gateway The units attempt to pair for 10 minutes and d...

Page 21: ...ntrol your central heating from outside of your home using your mobile phone or a remote computer The light on the router will flash red when it is first connected and setting up When connected to the...

Page 22: ...able and should be located in the area of your home heated by the Zone 2 radiators 1 Remove the battery cover on the back of the iT300TX 2 Insert the 2x AAA batteries supplied into the iT300TX 3 Repla...

Page 23: ...to return to previous screen or previous item In Program Mode long press to return to home screen without saving In Manual Override Mode long press to return to Auto Mode In Auto Mode long press to en...

Page 24: ...r Cooling on indicator HotWater indicator HotWater on indicator qualified below ON Continuously on 1 On once a day from program 1 ON to program 3 OFF AUTO Running in auto OFF Continuously off Indicate...

Page 25: ...connection fails Ch Aux Ch Aux Auto Manual Off Auto Manual Off switches Auto system controlled by programs in iT500TR Control Thermostat Manual system continuously on Off system continuously off Ch A...

Page 26: ...turned on Entering Installation Setup Mode Unless the display is already on press the Display ON button The display then switches on with the Home screen displayed Press and hold down both the Setting...

Page 27: ...ee different system configurations Once the required system configuration has been selected other installation options may be selected as described next This is the indicator for the single central he...

Page 28: ...as been specified the system configuration icon is displayed again but this time with the Heating mode indicator next to each icon This indicates that heating mode is selected Press if this is the mod...

Page 29: ...ess if Centigrade is your preferred choice If you prefer Fahrenheit press or The screen then displays the Fahrenheit unit Set the Time Zone After the temperature units have been selected you can selec...

Page 30: ...iT500 User Reference Manual 30 European Time Zones...

Page 31: ...LGARIA PORTUGAL BOSNIA CYPRUS ICELAND CROATIA ESTONIA CZECH REPUBLIC FINLAND DENMARK GREECE FRANCE LATVIA GERMANY LITHUANIA HOLLAND MOLDOVA ITALY ROMANIA LUXEMBOURG RUSSIA MALTA TURKEY NORWAY UKRAINE...

Page 32: ...Off After the time zone has been selected you may choose to turn Daylight Saving Time DST on or off The screen displays the default DST setting ON To set DST on press To turn DST off press the or butt...

Page 33: ...return to home screen When the iT500TR Thermostat in Normal mode press and together for two seconds The then flashes and then press Display shows the number 10 This is the time in minutes that the iT5...

Page 34: ...Using a paper clip insert into the hole marked SYNC at the bottom of the iT500RX Receiver The bottom switch will show a constant red light when the iT500RX Receiver is ready to pair When the iT500RX...

Page 35: ...event of RF signal loss your system will be switched on for 4 minutes then off for 11 minutes If you want to disable FAILSAFE MODE when RF link has been lost then move the slide switch on the iT500RX...

Page 36: ...to start sync count down To pair the iT300 to the receiver insert a paperclip or similar object into the hole on the left hand side of the iT300 for 2 seconds A red light will flash in the top right h...

Page 37: ...TR Thermostat can be controlled remotely it must be registered on the SALUS website 1 To register your iT500 online go to the SALUS controls website www salus controls com 2 Select your country 3 Clic...

Page 38: ...anual 38 4 Click on REGISTER then complete the form that is displayed and click REGISTER again 5 The screen below will then be displayed and a confirmation e mail will be sent to the e mail address yo...

Page 39: ...d password to log in then enter the STA number found in the battery compartment on the iT500 and press REGISTER 7 Your iT500TR will appear as below and is now ready to be controlled or viewed via your...

Page 40: ...on which kind of Smartphone you are using Find the iT500 App on the App Store and click download The App will automatically download to your Smartphone Once it is downloaded you can start controlling...

Page 41: ...41 Adding or Renaming the iT500 in your Device List When you first open the iT500 App your iT500TR will appear in the device list and you can start controlling it with your Smartphone Enter your user...

Page 42: ...e Manual 42 If you add more than one iT500 to your device list you may wish to rename the iT500 to DOWNSTAIRS for example Click on RENAME and enter a new name If you forget your password follow the on...

Page 43: ...can programme in your central heating and hot water settings as required Before doing this you should identify your system configuration as described next Identify your System Configuration There are...

Page 44: ...licts and the conflicting start times will have to be re set Temperature setpoint can be set for each program time period Days the programs apply to Days are numbered 1 to 7 where 1 is Monday and 7 is...

Page 45: ...e 6 00am Setpoint Temp 21 C 2 Time 8 00am Setpoint Temp 14 C OFF Time 8 00am Setpoint Temp 14 C 3 Time 11 00am Setpoint Temp 21 C ON Time 11 00am Setpoint Temp 21 C 4 Time 1 00pm Setpoint Temp 14 C OF...

Page 46: ...e system configurations for both the PC and the Smartphone app includes the following common settings and indicators Energy save will use the lowest set temperature on your daily schedule Will be disp...

Page 47: ...face for the PC and the Smartphone app for the One Central Heating Zone System Configuration Follows weekly schedule Energy save mode Home Holiday Settings Back Heatingcontinu ously off Override progr...

Page 48: ...iT500 User Reference Manual 48 Two Central Heating Zones The interface for the PC and the Smartphone app for the Two Central Heating Zones System Configuration...

Page 49: ...iT500 User Reference Manual 49 One Central Heating Zone plus Hot Water The interface for the PC and the Smartphone app for the One Central Heating Zone plus Hot Water System Configuration...

Page 50: ...iT500 User Reference Manual 50...

Page 51: ...et program times and setpoints Review programs Entering Settings Mode In Normal Home mode press for 2 seconds long press The unit then enters Settings mode The icon is displayed when the unit is in Se...

Page 52: ...time is displayed with the minutes flashing Press or until the required minute is displayed and then press The display will show the current setting 12 hr or 24 hr If this is the setting you want pres...

Page 53: ...m the month or to change it press or until the required month is displayed and press 7 After the month has been set and confirmed the current year is displayed with the year flashing Press to confirm...

Page 54: ...lus Hot Water you now have to select which of these you want to set the schedule for On the screen the Zone 1 icon will flash If your system configuration is One Central Heating Zone then that zone is...

Page 55: ...up is indicated by the number shown in the displayed under the time for example see the number 1 with the white background in the screen example above 4 The first stage in setting up a program is to s...

Page 56: ...he program will flash Use the and buttons to increase or decrease the temperature by 0 5 C or 0 5 F and press to confirm 7 Programming for program 1 is now complete The unit then switches to program 2...

Page 57: ...From Normal mode enter Settings mode by pressing for 2 seconds Then Press 2 On the screen the Zone 1 icon will flash Press The Hot Water icon will then flash Press to enter hot water programming 3 Sel...

Page 58: ...ing then flashes Adjust and confirm it in the same way as the hour setting Each press of or increases or decreases the minute setting by 10 minutes 6 OFF is then shown on the screen and the hour setti...

Page 59: ...e you choose at the time instead of according to its current program carry out the following steps 1 If your system configuration is One Central Heating Zone or if it is Two Central Heating Zones and...

Page 60: ...if it is Two Central Heating Zones and you want to turn off heating for Zone 1 or if it is One Central Heating Zone plus Hot Water simply press and together If your system configuration is Two Central...

Page 61: ...f To turn programmed central heating for a zone back on follow the above procedure and reset the unit to AUTO from OFF using the or buttons Override Hot Water Settings Turn On Hot Water for Set Number...

Page 62: ...displayed For example 4 The hot water settings are then displayed again with the override setting shown Note that the AUTO status indicator is no longer displayed in the bottom right hand corner of t...

Page 63: ...ime of program 1 to the OFF time of Program 3 Turn off hot water completely To turn on any of these overrides 1 In Normal mode press to switch to the Hot Water settings 2 Press and together The screen...

Page 64: ...emperature on your daily schedule Holiday override which for a set period of time changes the central heating setpoint to the same as the Frost Protection setpoint see below If Frost Protection is swi...

Page 65: ...s Frost protection automatically turns on heating for Central Heating when the temperature drops below the selected setpoint temperature Frost Protection automatically turns Central heating off when t...

Page 66: ...yed When the 2nd stage low voltage is reached the icon starts to flash Change the batteries as soon as possible Battery Installation or Replacement 1 To install or replace the batteries in the iT500 T...

Page 67: ...at Note The serial number of the iT500 Thermostat is on a label in the back of the battery compartment Resetting the iT500TR Thermostat To return your iT500 Thermostat to its factory settings insert a...

Page 68: ...splay will flash 1 2 3 4 5 6 to show that an update is in progress starting with 1 and rising to 6 Warning While the update is in progres do not exit the webpage or disconnect the device as this will...

Page 69: ...er the Air technology Date Format Days of the week 1 2 3 4 5 6 7 Time Format 12hr 24hr 12hr is the default Temperature C F the default is C 0 25 to 45 25 C range resolution is 0 25 C 1 9 C Frost Prote...

Page 70: ...range Power Supply x 2 AA alkaline batteries LR6 12 months life Flashing low battery indicator iTG500 Gateway Weight 50g not including adaptor Dimensions 91 x 38 5 x 25 5 mm Mounting Flat surface RF M...

Page 71: ...g not including batteries Dimensions 75 5mm x 75 5 mm x 22 5 mm Mounting Flat surface Channels Transmits to Heating Zone 2 only RF Module One way 868MHz Receiver 30 meters minimum range Power Supply...

Page 72: ...ronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inapprop...

Page 73: ...in accordance with its specification for a period of two years from the date of installation SALUS Controls sole liability for breach of this warranty will be at its option to repair or replace the de...