3. ESEMPI APPLICATIVI

4-20mA bar

4-20mA metri

Di seguito vengono illustrati alcuni esempi pratici delle applicazioni che è possibile realizzare con il 
quadro

 INVERTER  IRIS BLUE 2

.

LEGENDA COMPONENTI

Trasduttore di pressione 4-20mA

Galleggiante per acque pulite

Sonda piezoresistiva 4-20mA 

7

PIEZOR.

4-20m

  A

+-

C

O

M

.

E

X

T

.

ANALOG

4-20mA

X

-1

X

-2

X

-3

X

-4

TRANSD.

4-20mA

6

G.MIN

+-

C

O

M

.

E

X

T

.

ANALOG

4-20mA

X

-1

X

-2

X

-3

X

-4

Summary of Contents for IRIS BLUE 2

Page 1: ...ay Quadro elettronico avviamento inverter 2 motori con display rev 2 25 01 2021 INVERTER IRIS BLUE 2 SQ717 xx MANUALE DI ISTRUZIONE E INSTALLAZIONE INSTRUCTION AND INSTALLATION MANUAL customer service...

Page 2: ...amento 5 Schema elettrico 6 Programmazione 6 1 Programmazione marcia a secco 7 Parametri di default 8 Esempio funzionale di un impianto idraulico semplice 9 Smaltimento di vecchi apparecchi elettrici...

Page 3: ...a protetta secondo le normative in funzione dell applicazione Accertarsi che la potenza e la corrente di targa del motore rispecchino i limiti di impiego del quadro 1 ISTRUZIONI GENERALI PER L INSTALL...

Page 4: ...elle applicazioni che possibile realizzare con il quadro INVERTER IRIS BLUE 2 LEGENDA COMPONENTI Trasduttore di pressione 4 20mA Galleggiante per acque pulite Sonda piezoresistiva 4 20mA 7 PIEZOR 4 20...

Page 5: ...8Nm 10 mm Max 10 mm 1 4Nm 10 mm Max 6 mm 0 5Nm 10 mm TRASDUTTORE 4 20 mA COLLEGAMENTO TRASDUTTORE DI PRESSIONE MARRONE BIANCO P PRESSOSTATO O GALLEGGIANTE ALIMENTAZIONE 400 Vac 10 50 Hz M 3 U1 V1 W1 M...

Page 6: ...5 SCHEMA ELETTRICO 6...

Page 7: ...ITALIANO 5 SCHEMA ELETTRICO 7...

Page 8: ...impostati di default di marcia alla minima frequenza l inverter si arrester automaticamente attivando la modalit SLEEP Appena la pressione dell impianto si sar abbassata al di sotto della pressione di...

Page 9: ...bisogner programmare in modo particolare i seguenti parametri Una volta impostata la pressione desiderata bisogner premere il tasto ENTER e il parametro verr automaticamente memorizzato C018 corrente...

Page 10: ...rametri relativi a questa funzione Di seguito sono riportati i parametri interessati per questa funzione essi si trovano nel men PAR all interno del sottomen CONTROLLO MARCIA A SECCO P710b cos Soglia...

Page 11: ...erimento setpoint P710c 100 00 fnom P721 16 100 12 5 2 bar 12 5 C188a MDI4 C188c MDI8 P082a bar secondo riferimento setpoint PROTEZIONE MARCIA A SECCO DOVE RICHIESTA P713 tempo di autoreset 0 disattiv...

Page 12: ...12 8 ESEMPIO FUNZIONALE DI UN IMPIANTO IDRAULICO SEMPLICE 380V Comando di 2 pompe in cascata ad attivazione e disattivazione con controllo PID di pressione...

Page 13: ...ring diagram 5 Electrical diagram 6 Programming 6 1 Dry running programming 7 Default parameters 8 Functional exemple of a simple hydraulic system 9 Disposal of electrical electronic equipment 10 Decl...

Page 14: ...the installer s duty to verify the device after the installation although it has already undergone regular testing by the manufacturer 1 GENERAL INSTRUCTIONS FOR INSTALLING 2 WARNINGS Risk of electri...

Page 15: ...ANALOG 4 20mA X 1 X 2 X 3 X 4 3 APPLICATION EXAMPLES 4 20mA bar 4 20mA meters COMPONENTS KEY Float switch for clean water 4 20mA pressure transducer 4 20mA piezoresistive probe Below are some practica...

Page 16: ...mm Max 10 mm 1 4Nm 10 mm Max 6 mm 0 5Nm 10 mm TRANSDUCER 4 20 mA CONNECTION WITH PRESSURE TRANSDUCER BROWN WHITE P PRESSURE SWITCH OR FLOAT SWITCH POWER SUPPLY 400 Vac 10 50 Hz M 3 U1 V1 W1 MOTOR 1 R...

Page 17: ...ENGLISH 4 ELECTRICAL DIAGRAM 17...

Page 18: ...18 4 ELECTRICAL DIAGRAM...

Page 19: ...PID percentage P237 default 70 35Hz After about 20s set by default of running at minimum frequency the inverter will automatically stop activating the SLEEP mode The inverter will start up again as so...

Page 20: ...emi ENTER per iniziare Once the desidered pressure is set you will need to press the ENTER key and the parameter will automatically be stored C018 motor 1 rated current After having set the reference...

Page 21: ...be programmed also to intervene in case of dry running By default it is already programmed but it is recommended after putting the system into operation to review some parameters related to this func...

Page 22: ...14 filter time constant for variable 300ms 3 SETPOINT MANAGING IF REQUIRED C188a MDI4 P084a bar terzo riferimento setpoint P710 power factor cosphi P082a bar secondo riferimento setpoint DRY RUNNING P...

Page 23: ...KM1 pump 2 Alternatively Direct starting Star delta starting Soft Starte Stop starting Direct pump 2 Modular pump 1 Power supply 380V Control of 2 pumps in cascade for activation and deactivation wit...

Page 24: ...hat SALUPO S r l Technical Dep Manager Salupo Ivan 24 SALUPO S r l Salupo Ivan Responsabile Ufficio Tecnico 10 DICHIARAZIONE DI CONFORMITA Il costruttore C da Pietra di Roma Vicolo VI n 2 i quadri INV...

Page 25: ...i responsabilit per danni cagionati da caduta uso scorretto alterazione o negligenza 4 Questa garanzia non incide sui diritti del consumatore sanciti dalla normativa vigente Salupo S r l Salupo S r l...

Page 26: ...________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ____...

Page 27: ...________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ____...

Page 28: ...C da Pietra di Roma Via Vicolo VI n 2 98070 Torrenova ME ITALY Tel 39 0941 950216 Fax 39 0941 958777 www salupoquadri com info salupoquadri com e mail...

Reviews: