1. Model confirmation

When you open the package, you will see the following items:

1x Main Machine

1x Power Cord

1x U Disk (for documents)

Please check carefully for any incorrect or missing items against the order contract and the packing list. If
there is any problem, please contact our operation center according to the contact information in the
preface, and we will solve it as soon as possible.

2. Visual examination

Check the instrument carefully for any damage during transportation. It is strictly prohibited to switch on
the instrument if any obvious damage to the instrument is found. Please contact our operation center
according to the contact information in the preface. We will repair or replace the product accordingly as
soon as possible.

3. Operating environment

Please refer to the environmental adaptability part in Technical Indicators section of this manual. And
please pay special attention to the following requirements:
Power supply: 220V (±10%), 50Hz (±5%)
Power socket:

3-core power socket must be used, and grounding is strictly required.

Power cable of the instrument:

3-core power cable provided in the package

For the safety of users, anti-static accessories must be provided with at least 1M

isolation resistance

from ground.

Before connecting the solid-state power amplifier to the power supply, please check carefully whether the
supply voltage is normal and whether the connector at the output end of the amplifier is connected with a
high-power load, otherwise it is very likely to cause damage to the instrument!

4. Electrostatic protection

Static electricity is extremely destructive to electronic components and instruments. The required
anti-static measures must be completed on an anti-static workbench. Usually we take two anti-static
measures: conductive table mat and wrist strap, conductive floor mat and ankle strap. For the safety of
users, anti-static accessories must be provided with at least 1M

isolation resistance from ground.

Summary of Contents for S3871 Series

Page 1: ...S3871 Series Solid State Power Amplifier User Manual Saluki Technology Inc...

Page 2: ...54dB S3871AK Power Amplifier 80MHz 1GHz 56dB S3871AA Power Amplifier 1GHz 2 5GHz 53dB S3871AP Power Amplifier 1GHz 2 5GHz 55dB S3871AB Power Amplifier 1GHz 6GHz 48dB S3871AQ Power Amplifier 2GHz 6GHz...

Page 3: ...r 37GHz 43GHz 46dB S3871FE Power Amplifier 26GHz 40GHz 43dB S3871FF Power Amplifier 26GHz 40GHz 49dB S3871FG Power Amplifier 26GHz 40GHz 53dB S3871FP Power Amplifier 18GHz 40GHz 46dB S3871FQ Power Amp...

Page 4: ...C 150 6GHz 18GHz 150W S3871DH 005 2GHz 18GHz 5W S3871DH 010 2GHz 18GHz 10W S3871DK 080 2GHz 18GHz 80W S3871EB 040 18GHz 26 5GHz 40W S3871EB 060 18GHz 26 5GHz 60W S3871EB 080 18GHz 26 5GHz 80W S3871EC...

Page 5: ...r tampered by any organization or individual or reproduced or transmitted for the purpose of making profit without its prior permission otherwise Saluki will reserve the right to investigate and affix...

Page 6: ...886 909 602 109 Email sales salukitec com www salukitec com 6 Contacts Service Tel 886 909 602 109 Website www salukitec com Email sales salukitec com Address No 367 Fuxing N Road Taipei 105 Taiwan R...

Page 7: ...peration Guide 11 3 1 Front Panel Features 12 3 2 Rear Panel Features 13 Chapter 4 Working Principle 14 Chapter 5 Technical Specifications and Indicator Tests 15 5 1 Main Indicators and Performance Ch...

Page 8: ...atibility testing high power electric vacuum device testing non linear testing of high power components and so on As indispensable important instruments in broadband high power testing systems they ha...

Page 9: ...hnical Indicators section of this manual And please pay special attention to the following requirements Power supply 220V 10 50Hz 5 Power socket 3 core power socket must be used and grounding is stric...

Page 10: ...reduce electrostatic damage ensure correct grounding of all instruments prevent the generation of static electricity operators must wear anti static wrist straps before touching the connectors the cor...

Page 11: ...s and gains In terms of protective design the instrument features many alarm and protection functions Firstly the instrument offers air cooling alarm and protection over temperature alarm and protecti...

Page 12: ...RF input signals of the solid state power amplifier 3 RF Output connector The RF output connector is used for outputting the RF output signals of the solid state power amplifier 4 Gain Power Regulator...

Page 13: ...working switch of the front panel is in the standby state by default and will be switched to the working state after pressing the key 3 2 Rear Panel Features The configuration of the rear panel of S3...

Page 14: ...etting Wizard keys on the front panel of the instrument the working state can be set to Open Loop At this time microwave signals are input from the RF frequency input end of the amplifier then amplifi...

Page 15: ...3871AH 80MHz 1GHz 54 51 N f N f S3871AK 80MHz 1GHz 56 53 N f N f S3871AA 1GHz 2 5GHz 53 50 N f N f S3871AP 1GHz 2 5GHz 55 52 N f N f S3871AB 1GHz 6GHz 48 45 N f N f S3871AQ 2GHz 6GHz 53 50 N f N f S38...

Page 16: ...2 4mm m 2 4mm m S3871FF 26GHz 40GHz 49 46 2 4mm m WR28 S3871FG 26GHz 40GHz 53 50 2 4mm m WR28 S3871FP 18GHz 40GHz 46 43 2 4mm m 24JS18000 S3871FQ 18GHz 40GHz 50 47 2 4mm m 24JS18000 S3871FR 18GHz 40G...

Page 17: ...tput power VS Frequency S3871EA Output power VS Frequency S3871DA Output power VS Frequency S3871AA Output power VS Frequency S3871AB Output power VS Frequency 2 General information 1 Environmental re...

Page 18: ...state power amplifier to the power supply place the power switch on the rear panel to the position the On position and the standby power indicator on the front panel will be on When the working switc...

Page 19: ...lid state power amplifier clockwise to the end conduct the gain test according to the connection system shown in Figure 5 1 and record the value S21 as the gain value of the amplifier 2 Input port vol...

Page 20: ...the max output power degree and the attenuation value on the attenuator which is just the max output power 2 Max input power test observe the working state of the amplifier at the max input power It...

Page 21: ...Non harmonic Suppression Test a Testing equipment Signal source S1465 1 Spectrum analyzer 4036 1 High power attenuator 89 30 21 1 b Testing diagram Figure 5 3 Diagram of the non harmonic suppression t...

Page 22: ...lifier itself first Before the test check whether the accessories connected with the solid state power amplifier and the interfaces between them are normal to ensure that the problem is not caused by...

Reviews: