background image

Tel: 886.909 602 109 Email: [email protected]

www.salukitec.com

11

Chapter 3 Operation Guide

The S3871 series solid-state power amplifiers cover a frequency range of 1GHz - 60GHz and a unit
output power range of 1W - 100W. Adopting the most advanced broadband space power synthesis
technology in the world at present, they have completely independent intellectual property rights and
adopt the external structure as standard bench top instruments.
The interface is simple and user-friendly, allowing for simple and convenient operation. The panel
consists of five parts, namely, RF input port, RF output port, function setting keys, gain regulator and
power display interface. The function setting keys are used to set different working states of the power
amplifier, and the gain regulator is used to set the gain and output power of the power amplifier. The
display interface is divided into two parts, one for working status and the other for function settings. The
working state display interface can display the output power and incident power. The current working
frequency is shown on the top of the display and the status bar, located on the bottom of the display,
shows whether the current work is in a local state or in a remote-control state, in an open loop state or in a
stable amplitude state. The instrument can display the output power as well as the two working states of
open loop and internal amplitude stabilization. In the open loop state, adjusting the gain regulator allows
you to realize different output powers and gains.
In terms of protective design, the instrument features many alarm and protection functions. Firstly, the
instrument offers air-cooling alarm and protection, over-temperature alarm and protection, mismatch
alarm and protection. The thresholds of over-temperature alarm and mismatch alarm can be flexibly set as
required by users. When an alarm is generated, you can also take different countermeasures, such as
minimizing the gain or cutting off the RF. Another protection of the instrument is the working state
locking function. When the working state is set to locked, the current gain and output power will not be
changed even if the gain regulator is turned. This function can effectively prevent power change caused
by incorrect operation or carelessness of users, thus ensuring the safety of the measured piece.
As for humanized design, first of all, the RF input port and RF output port are provided separately on the
left and right sides of the front panel to facilitate users to connect cables or measured pieces. Secondly,
the display interface displays not only the output power, but also the incident power. The display units are
W and dBm respectively. In addition, you can also choose to the display only the output power and not
the incident power.
The instrument also has the following features: working state selectable between open-loop and internal
stable amplitude, working state selectable between local and remote control, working interface selectable
between Chinese and English, selectable alarm processing modes and selectable adjustment direction for
the gain regulator. Such features increase users’ selectivity to the working state, meet different demands
of users, and improve the convenience of use.

Summary of Contents for S3871 Series

Page 1: ...S3871 Series Solid State Power Amplifier User Manual Saluki Technology Inc...

Page 2: ...54dB S3871AK Power Amplifier 80MHz 1GHz 56dB S3871AA Power Amplifier 1GHz 2 5GHz 53dB S3871AP Power Amplifier 1GHz 2 5GHz 55dB S3871AB Power Amplifier 1GHz 6GHz 48dB S3871AQ Power Amplifier 2GHz 6GHz...

Page 3: ...r 37GHz 43GHz 46dB S3871FE Power Amplifier 26GHz 40GHz 43dB S3871FF Power Amplifier 26GHz 40GHz 49dB S3871FG Power Amplifier 26GHz 40GHz 53dB S3871FP Power Amplifier 18GHz 40GHz 46dB S3871FQ Power Amp...

Page 4: ...C 150 6GHz 18GHz 150W S3871DH 005 2GHz 18GHz 5W S3871DH 010 2GHz 18GHz 10W S3871DK 080 2GHz 18GHz 80W S3871EB 040 18GHz 26 5GHz 40W S3871EB 060 18GHz 26 5GHz 60W S3871EB 080 18GHz 26 5GHz 80W S3871EC...

Page 5: ...r tampered by any organization or individual or reproduced or transmitted for the purpose of making profit without its prior permission otherwise Saluki will reserve the right to investigate and affix...

Page 6: ...886 909 602 109 Email sales salukitec com www salukitec com 6 Contacts Service Tel 886 909 602 109 Website www salukitec com Email sales salukitec com Address No 367 Fuxing N Road Taipei 105 Taiwan R...

Page 7: ...peration Guide 11 3 1 Front Panel Features 12 3 2 Rear Panel Features 13 Chapter 4 Working Principle 14 Chapter 5 Technical Specifications and Indicator Tests 15 5 1 Main Indicators and Performance Ch...

Page 8: ...atibility testing high power electric vacuum device testing non linear testing of high power components and so on As indispensable important instruments in broadband high power testing systems they ha...

Page 9: ...hnical Indicators section of this manual And please pay special attention to the following requirements Power supply 220V 10 50Hz 5 Power socket 3 core power socket must be used and grounding is stric...

Page 10: ...reduce electrostatic damage ensure correct grounding of all instruments prevent the generation of static electricity operators must wear anti static wrist straps before touching the connectors the cor...

Page 11: ...s and gains In terms of protective design the instrument features many alarm and protection functions Firstly the instrument offers air cooling alarm and protection over temperature alarm and protecti...

Page 12: ...RF input signals of the solid state power amplifier 3 RF Output connector The RF output connector is used for outputting the RF output signals of the solid state power amplifier 4 Gain Power Regulator...

Page 13: ...working switch of the front panel is in the standby state by default and will be switched to the working state after pressing the key 3 2 Rear Panel Features The configuration of the rear panel of S3...

Page 14: ...etting Wizard keys on the front panel of the instrument the working state can be set to Open Loop At this time microwave signals are input from the RF frequency input end of the amplifier then amplifi...

Page 15: ...3871AH 80MHz 1GHz 54 51 N f N f S3871AK 80MHz 1GHz 56 53 N f N f S3871AA 1GHz 2 5GHz 53 50 N f N f S3871AP 1GHz 2 5GHz 55 52 N f N f S3871AB 1GHz 6GHz 48 45 N f N f S3871AQ 2GHz 6GHz 53 50 N f N f S38...

Page 16: ...2 4mm m 2 4mm m S3871FF 26GHz 40GHz 49 46 2 4mm m WR28 S3871FG 26GHz 40GHz 53 50 2 4mm m WR28 S3871FP 18GHz 40GHz 46 43 2 4mm m 24JS18000 S3871FQ 18GHz 40GHz 50 47 2 4mm m 24JS18000 S3871FR 18GHz 40G...

Page 17: ...tput power VS Frequency S3871EA Output power VS Frequency S3871DA Output power VS Frequency S3871AA Output power VS Frequency S3871AB Output power VS Frequency 2 General information 1 Environmental re...

Page 18: ...state power amplifier to the power supply place the power switch on the rear panel to the position the On position and the standby power indicator on the front panel will be on When the working switc...

Page 19: ...lid state power amplifier clockwise to the end conduct the gain test according to the connection system shown in Figure 5 1 and record the value S21 as the gain value of the amplifier 2 Input port vol...

Page 20: ...the max output power degree and the attenuation value on the attenuator which is just the max output power 2 Max input power test observe the working state of the amplifier at the max input power It...

Page 21: ...Non harmonic Suppression Test a Testing equipment Signal source S1465 1 Spectrum analyzer 4036 1 High power attenuator 89 30 21 1 b Testing diagram Figure 5 3 Diagram of the non harmonic suppression t...

Page 22: ...lifier itself first Before the test check whether the accessories connected with the solid state power amplifier and the interfaces between them are normal to ensure that the problem is not caused by...

Reviews: