Salto CU42 Series Installation Manual Download Page 1

All contents current at time of publication.
SALTO Systems S.L. reserves the right to change availability of any
item in this catalog, its design, construction, and/or materials.

224901 -ED0 -01/09/2015

European view

©

2015 SALTO Syst ems S.L.

1/8

 CU42xx 

READER 1

A

B

TAMPER

IN1

IN2

IN3

IN4

IN5

IN6

READER 2

RL1

RL2

RL3

RL4

C

NC

NO

C

NC

NO

C

NC

NO

C

NC

NO

BUS485

Ethernet

10Base-T

100Base-TX

ON

12V

DC

 Input

+

A

B

-

12V

DC

 Output (1A)

Power Input: 12V

DC

-1A

GND

GND

+

-

+

-

+

-

+

-

+

-

+

-

+

-

A

B

+

-

Model:

 CU42E0

104

[4-1/8"]

12

1

[4-

3/4

"]

43

[1-11/16"]

10

[3/8"]

44

[1-3/4"]

13

1

[5-

3/1

6"

]

Ø

4

[5/32

"]

Mechanical Installation:

Instalación mecánica:

Eng

Esp

Deu

CU42xx Installation Guide

Guía de instalación CU42xx

Installationsanleitung CU42xx

Guide d'installation CU42xx

Installatiehandleiding CU42xx

Installationsguide CU42xx

Eng

Esp

Deu

Fra

Ned

Sve

Mechanische Installation:

Installation mécanique:

Fra

Ned

Sve

CU42E0

CU4200

CU42E0T - CU42E0G - CU4200T - CU4200G

Mechanische installatie:

Mekanisk installation:

 

TAMPER

3

2

1

Do not use the jumper 
on tamper input.
No utilizar cable nulo en 
entrada Tamper
Bei Verwendung vom Gehäuse, 
keineBrücke auf Tamper machen

Eng

Esp

Deu

Fra

Ned

Sve

Ne pas mettre de cavalier 
sur l’entrée anti-sabotage.
Gebruik geen brugkabel op 
de sabotage ingang.
Använd inte bygeln på 
Tamper-ingången.

Electric box with tamper switch.
Caja eléctrica con detector de 

intrusion o tamper.
Box mit Sabotagekontakt.
Coffret électrique avec

interrupteur anti sabotage.
Bij een behuizing met 

sabotage schakelaar dient 

deze aangesloten te worden.
Elektroniskt box med 

sabotagebrytare.

Eng

Esp

Deu

Fra

Ned

Sve

Summary of Contents for CU42 Series

Page 1: ...2xx Guide d installation CU42xx Installatiehandleiding CU42xx Installationsguide CU42xx Eng Esp Deu Fra Ned Sve Mechanische Installation Installation m canique Fra Ned Sve CU42E0 CU4200 CU42E0T CU42E0...

Page 2: ...an het einde van de bus ligt Voeding ingang Voeding uitgang Deze output is direct verbonden met de power input poort beschermd door een 1A zekering BUS485 Ingangen Installateur moet vaststellen welke...

Page 3: ...Note 3 1K pull up resistor Note 4 See the software User Manual Note 5 When Ethernet is available Esp Caracter sticas Electricas Condiciones ambientales Min Typ Max Unit Temperatura 0 25 60 C Humedad 3...

Page 4: ...ote 2 M me tension que l entr e Note 3 R sistance de pull up 1K Note 4 Consultez le manuel du logiciel utilisateur Note 5 Si connectique Ethernet Ned Technische gegevens Omgeving Min Typ Max Eenheid T...

Page 5: ...EXIT Elektrische sluitplaat 1 2 3 Esp Contacto NC puerta Contacto NO RTE Cerradero el ctrico 1 2 3 Deu T rkontakt Schlie er T r ffnungstaster Schlie er T r ffner 1 2 3 Fra Etat de la porte NC Bouton p...

Page 6: ...nnen Ihn manuell abbrechen wenn Sie die CLR Taste l nger als 5 Sekunden gedr ckt halten 4 Pr fen Sie in der ProAccess SPACE Software ob alle Komponenten korrekt erkannt wurden Hierzu bei Bedarf das H...

Page 7: ...Deze instelling moet gelijk zijn zoals in de software is aangegeven Zie tabel hiernaast Bij begin en eind van de 485BUS moeten de eindweerstanden op de ON positie staan Een CU4200 of CU420E die tusse...

Page 8: ...schlossen ist bitte den CLR Button einmal kurz dr cken um die Erkennung zu starten RL1 RL4 EIN Das Relais ist aktiv NO und C verbunden AUS Das Relais ist nicht aktiv NC und C verbunden Deu Signale De...

Reviews: