APPENDIX C: DISPLAYED
ERROR CODES
CODE
MODE
MEANING / POSSIBLE SOLUTION
Normal Operating
Mode
Gross Overload. A weight greater than the rated capacity has been
applied to the scale. Remove the weight from the platter or try re-
calibrating the scale. Otherwise, check for a bad load cell connection or
possible load cell damage due to overloading.
Err 0
Span Calibration
Mode (F17)
Keyed-in weight value is less than 1% of full-scale capacity. Use a larger
test weight or check keyed-in value.
Err 1
Span Calibration
Mode (F17)
Keyed-in weight value is larger than full-scale capacity. Use a smaller test
weight or check keyed-in value.
Err 2
Span Calibration
Mode (F17)
There is not enough load cell signal to produce the internal counts
necessary to properly calibrate the scale. First check all load
connections. Use F16 mode to view internal counts. See Appendix C for
more information.
Err 3
All Modes
Non-volatile memory read error. One or more setup parameters have
been lost.
Err 4
All Modes
Non-volatile memory write error. Indicator needs service.
Err 7
Initialization
No reading from the ADC. Could indicate a damaged load cell.
Err 9
Normal Operating
Mode
Span calibration value has been lost. Re-calibrate the scale.
Err 10
Initialization or Setting
Code Entry
Indicator cannot read serial number. Indicator must be returned for
service.
Err 11
Initialization
Serial number mismatch. Re-enter setting code from product ID tag.
Err 12
Initialization or Setting
Code Entry
Invalid setting code. Re-enter proper setting code from product ID tag.
Err 13
Setting Code Entry
Non-volatile memory is in write-protect mode. Toggle position of
Setup/Calibration Switch (See Chapter 5).
Note:
Contact Service Department at Transcell for instructions on how to re-enter setting code.