SMARTY XV v2020.2

SMARTY

 3

XV

 V

1.

2

Climate zone

Control typology

Control factor 

Specific energy 

consumption 

(SEC)

SEC Class

AEC

AHS

[ kWh/m²/a ]

[ kWh/a ]

 [ kWh/a ]

Average

Clock control (standard)

0,95

-37,2

A

339

4504

Central demand control (opt. with 1 sensor)

0,85

-39,1

A

280

4546

Local demand control (opt. with 2 sensors)

0,65

-

-

-

-

Cold

Clock control (standard)

0,95

-74,9

A+

876

881

Central demand control (opt. with 1 sensor)

0,85

-77,2

A+

817

8893

Local demand control (opt. with 2 sensors)

0,65

-

-

-

-

W

arm

Clock control (standard)

0,95

-13,0

E

294

2037

Central demand control (opt. with 1 sensor)

0,85

-14,7

E

235

2056

Local demand control (opt. with 2 sensors)

0,65

-

-

-

-

Declared typology

Bidirectional

Type of drive installed (fan)

Variable

Type of heat recovery system

Recuperative

Thermal efficiency of heat recovery

[ % ]

86,9

Maximum flow rate

[ m

3

/h ]

394

Electric 

power 

input 

of 

the 

fan 

drive 

at 

maximum 

flow 

rate

[ W ]

170

Sound power level (Lwa)

[ dB(A) ]

50

Reference flow

[ m

3

/s ]

0,077

Reference pressure difference

[ Pa ]

50

SPI

[ W/(m

3

/h) ]

0,26

Control factor and control typology

0,95

Declared maximum internal leakage rates

[ % ]

1,2

Declared maximum external leakage rates

[ % ]

1,2

Possition 

and 

description 

of 

visual

 filter 

warning 

for 

RV

U

’s

Timer

ErP

 Compliance

2018

Internet address for disassembly instructions

www

.salda.lt

Summary of Contents for SMARTY XV Series

Page 1: ...SMARTY XV EN MOUNTING AND INSTALLATION INSTRUCTION...

Page 2: ...RECOMMENDATIONS FOR THE MAINTENANCE OF VENTILATION SYSTEM 14 6 3 COVER OPENING 14 6 4 FILTERS MAINTENANCE 15 6 5 FANS MAINTENANCE 15 6 6 HEAT EXCHANGER MAINTENANCE 16 6 7 BYPASS DAMPERS AND PRE HEATER...

Page 3: ...n about the unit Figure 2 1 Technical label 1 Logo 2 Product code SKU 3 Product name 4 Technical data 5 Production place 6 production date 7 Serial number Figure 2 2 Indication for duct connection ODA...

Page 4: ...touch heating elements until they haven t cooled down Some devices are heavy thus one should be very careful while transporting and installing Use suitable lifting equipment While connecting electric...

Page 5: ...o C to 40 o C For the cold climate zones air temperatures below 2 o C integrated or optional pre heater is required if airflow misbanancing is disabled Product name Control board Type Heat recov ery T...

Page 6: ...niMCB basic miniMCB miniMCB basic Insulation of walls mm 30 30 30 30 30 30 Exhaust air filter class dimensions LxWxH mm MPL 270x187x25 Coarse 65 MPL 475x180x25 Coarse 65 MPL 475x180x25 Coarse 65 Suppl...

Page 7: ...o C 5 o C Maximum ambient air temperature 40 o C 40 o C 40 o C 40 o C 40 o C 40 o C Installation indoor only indoor only indoor only indoor only indoor only indoor only 4 5 STANDART PACKAGE OF COMPONE...

Page 8: ...C and 30 C The place of storage must be protected against dirt and water The units must be transported to the storage or installation site using forklifts The storage is not recommended for a period...

Page 9: ...ptional Figure 5 4 2 SMARTY XV miniMCB basic Only heater or preheater can be connected at a time Check the manual for details Optional LIST OF COMPONENTS C Plate heat exchanger KE1 Electric heater PV...

Page 10: ...he unit and the first branch of the air duct in the supply air duct must be 1xD in air exhaust duct 3xD where D is diameter of the air duct It is recommended to use the accessories holders This will r...

Page 11: ...00 mm 5 7 FLOOR MOUNTING Figure 5 7 1 floor mounting optional accessory required 5 8 MOUNTING ON WALL b 30 mm a c d 90 90 Figure 5 8 1 mounting on the wall 5 9 DRAINAGE Before every heating season the...

Page 12: ...egrees 1 meter of pipe must be bended 60 mm downwards Before turning on AHU 1 the draining system should be filled up with at least 0 5 l of water pipe loop 3 must be always filled with water also che...

Page 13: ...et distribution devices Prior to carrying out any ventilation unit installation and connection activities until its hand over to the customer the unit must be disconnected from the power network After...

Page 14: ...rs do not cause noise when rotated by hand Make sure that the fastening screws are not loose and free of mechanical damage Check electrical connections and make sure that these are se cured properly a...

Page 15: ...rom X16 X2 X4 Detach fan from the unit Impeller should be specially checked for buil up material or dirt which may cause an imbalance Excessive imbalance can lead to accelerated wear on motor bearings...

Page 16: ...warm soapy water do not use soda Then rinse it with weak hot water stream too strong stream can fold the plates Place back the heat exchanger only when it is completely dry Figure 6 6 1 Smarty 2XV Fi...

Page 17: ...the marking on the controller terminals is not visible follow the PCB information provided in this passport see miniMCB description Fig 2 and Fig 3 1 2 3 6 9 SMARTY 4XV SWITCHING POWER SUPPLY MAINTEN...

Page 18: ...IONS All MCB control boards has the same software with all functions included Full function list and description you can find on the MCB control board manual However operation and control of the devic...

Page 19: ...ACC003807 EKA NIS 125 0 6 1 f ACC000319 EKA NIS 125 0 9 1 f ACC000320 EKA NIS 125 1 2 1f ACC003803 EKA NIS 125 1 5 1 f ACC000321 EKA NIS 125 1 8 1 f ACC000322 EKA 160 0 3 1 f ACC003723 EKA 160 0 6 1 f...

Page 20: ...or circular Mute 160x600 Smarty 3 4XV Mute 160x600 FIT000289 Attenuator circular Mute 160x900 Smarty 3 4XV Mute 160x900 FIT000290 Dampers circular shut off sealed blade d125 SKG A 125 FIT000201 Damper...

Page 21: ...EKA NIS connection Automatic and manual protection shall be connected to EX1 controllers X23 connector if the electric heater is equipped with these connection terminals Otherwise jumpers are install...

Page 22: ...2 units have one connection of external electrical heater pre heater In factory settings connection is dedicated for the pre heater but can be configured for the heater Heater pre heater can be contro...

Page 23: ...EN 23 SMARTY XV v2020 2 EKA NIS connection...

Page 24: ...he environment of the MB Gateway WEB application service or on the ST SA Control panel Settings in the environment of the MB Gateway WEB application service Change the settings as follows Service pass...

Page 25: ...ater protection Set the manual and automatic protection statuses according to the standards it should be NC 6 Go to Menu Service Digital inputs Preheater protection Set the manual and automated protec...

Page 26: ...sensors Sensors connection 24VDC AI4 0 10V GND 1 2 3 4 5 6 7 8 AO1 GND Vin Transmiter 1 Supply air CO2 or RH input 0 10VDC 24VDC GND 1 2 3 AI1 0 10V Vin GND AO1 Transmitter 2 Smarty 3XV 1 1 and Smart...

Page 27: ...ncentration drowsi ness headache etc 1500 1000 Pettenkofer limit Pettenkofer limit Disturbs 500 Pleasant 0 0 1 2 3 4 Duration of the presence in the room in hours Closed windows Controlled ventilation...

Page 28: ...ermination resistor On Off 8 1 8 FIRE PLACE CONNECTION SMARTY XV 1 1 Wiring diagram Automation controller C zone X23 connector 1 2 3 4 5 6 7 8 Fire Place II DI4 12VDC 12VDC DI3 Fire Place I LED indica...

Page 29: ...Jumper 7 Punktyrine linija pa ym tus komponentus ir kabelius pajungia SALDA arba vartotojas Components and cables marked with the dash line connected by SALDA or customer Bypass actuator for versions...

Page 30: ...30 EN SMARTY XV v2020 2 Figure 8 1 9 2 Smarty 2XV 1 1 Smarty 2XV 3XV 4XV 1 2 219 1017 0 1 2 PS...

Page 31: ...EN 31 SMARTY XV v2020 2 C H C C H C Figure 8 1 9 3 Smarty 2XV 1 1 Smarty 2XV 3XV 4XV 1 2 219 1017 0 1 3 PS...

Page 32: ...AME DATE UAB SALDA Drawing Book CHECKED BY 1 1 2 3 4 4 5 6 7 7 EI D Aleksandravi ius EI A klenikas Pyn l Smarty 3XV PE 0k 221 1011 0 1 0 PS 0k Principle connection scheme 8 01 2015 11 24 2015 11 24 20...

Page 33: ...35 Red 0 35 Yellow 0 35 Blue 0 35 Yellow 0 35 Blue 0 35 Brown Black 0 5 Green yellow 0 5 Blue 0 5 Brown Black 0 5 Blue 0 5 Green yellow 0 5 Figure 8 1 9 6 Smarty 2XV 3XV Fans MiniMCB DRAWN BY CHECKED...

Page 34: ...1 PE X12 2 N L1 X12 3 DO2 L L2 N2 miniMCB V0 3 01 6 3 X2 5 GND X2 6 AO3 0 10V N2 miniMCB V0 3 01 5 3 External preheater Control 0 10V Power over 2kW 2f 400V K1 A1 A2 230VAC 11 14 K1 K1 1 2 3 4 PE L1 L...

Page 35: ...NTC X6 2 GND N1 miniMCB V0 3 G1 L N PE V V PE X9 1 24VDC_IN X9 2 GND X9 3 PE N1 miniMCB V0 3 X3 1 24VDC X3 2 STEP_B X3 3 STEP_B X3 4 STEP_A X3 5 STEP_A X3 6 24VDC N1 miniMCB V0 3 X5 5 DI7 X5 6 12VDC N...

Page 36: ...4 12VDC N1 miniMCB V0 3 X8 1 GND X8 2 24VDC_P X8 3 12VDC X8 4 3 3VDC X8 5 2 5VDC_REF X8 6 GND X8 7 I2C_CDA X8 8 I2C_SCL N1 miniMCB V0 3 X22 1 GND X22 2 24VDC X22 3 12VDC X22 4 3 3VDC X22 5 2 5VDC_REF...

Page 37: ...1 miniMCB V0 3 Punktyrine linija pa ym tus komponentus ir kabelius pajungia SALDA arba vartotojas Components and cables marked with the dash line connected by SALDA or customer Optional CO2 input 0 10...

Page 38: ...nsor DTJ ACC002486 Temp sensor TJ ACC002560 By pass drive 15 D SEE 202 GPYSM221_0_1007 Heat exchanger ZSLPLRU0001 Fan supply Smarty 3XV 1 1 GPUVM224_1032_1032 Fan supply Smarty 3XV 1 2 GPUVM224_1034_1...

Page 39: ...EN 39 SMARTY XV v2020 2 Doors GPUD232_1028_0 By pass damper Smarty 4XV 1 1 GPUSK227_1004_1016 By pass damper Smarty 4XV 1 2 GPUSK227_1006_1016...

Page 40: ...erat ing or malfunctioning if installed Too low air flow in air ducts activates auto matic protection Check if air filters are not clogged Check if fans are rotating Manual protection is activated Pos...

Page 41: ...E 350 2085 Central demand control opt with 1 sensor 0 85 14 0 E 281 2098 Local demand control opt with 2 sensors 0 65 17 2 E 164 2126 Declared typology Bidirectional Type of drive installed fan Varia...

Page 42: ...demand control opt with 1 sensor 0 85 14 0 E 281 2098 Local demand control opt with 2 sensors 0 65 Declared typology Bidirectional Type of drive installed fan Variable Type of heat recovery system Rec...

Page 43: ...sensor 0 65 17 5 E 138 2093 Declared typology Bidirectional Type of drive installed fan Variable Type of heat recovery system Recuperative Thermal efficiency of heat recovery 86 9 Maximum flow rate m...

Page 44: ...emand control opt with 1 sensor 0 85 14 7 E 235 2056 Local demand control opt with 2 sensors 0 65 Declared typology Bidirectional Type of drive installed fan Variable Type of heat recovery system Recu...

Page 45: ...sensor 0 65 15 2 E 212 2047 Declared typology Bidirectional Type of drive installed fan Variable Type of heat recovery system Recuperative Thermal efficiency of heat recovery 82 Maximum flow rate m 3...

Page 46: ...demand control opt with 1 sensor 0 85 10 9 E 362 1996 Local demand control opt with 2 sensors 0 65 Declared typology Bidirectional Type of drive installed fan Variable Type of heat recovery system Re...

Page 47: ...The following harmonized standards are applied in applicable parts LST EN ISO 12100 2011 Safety of machinery General principles for design Risk assessment and risk reduction LST EN 60204 1 2006 Safety...

Page 48: ...e equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors or i...

Page 49: ...49 SMARTY XV v2020 2...

Page 50: ...50 SMARTY XV v2020 2...

Page 51: ...51 SMARTY XV v2020 2...

Page 52: ...INTENANCE TABLE Product name SERIAL number Instalation Interval Date Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product label At least...

Reviews: