DECLARATION OF CONFOMITY

Manufacturer

SALDA, UAB

Ragainės g. 100

LT-78109 Šiauliai, Lithuania

Tel.: +370 41 540415

www.salda.lt

Hereby confirms that the following products - Air handling units:

Fan*

(where by “*” indicates possible unit installation type and modification)

Provided it was delivered and installed in the facility in accordance with the included installation instructions, comply

with all applicable requirements in the following directives:

Machinery Directive 2006/42/EC

Low Voltage Directive 2006/95/EC

EMC Directive 2014/30/EU

The following regulations are applied in applicable parts:

Ecodesign requirements for ventilation units Nr. 1253/2014;

Energy labeling of residential units Nr. 1254/2014.

The following harmonized standards are applied in applicable parts:

LST EN ISO 12100 - Safety of machinery - General principles for design - Risk assessment and risk reduction.

LST EN 60204-1 - Safety of machinery - Electrical equipment of machines - Part 1: General requirements.

LST EN 60335-1 - Household and similar electrical appliances. Safety. Part 1: General requirements.

LST EN 60529 - Degrees of protection provided by enclosures (IP code).

LST EN 60034-5 - Rotating electrical machines. Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP

code)

LST EN 61000-6-2 - Electromagnetic compatibility (EMC) -- Part 6-2: Generic standards - Immunity for industrial environments.

LST EN 61000-6-3 - Electromagnetic compatibility (EMC) -- Part 6-3: Generic standards - Emission standard for residential, commercial and

light-industrial environments. 

Should any alterations be made in the products, this declaration will no longer apply.

Notified body: 

VšĮ Technikos priežiūros tarnyba, Naugarduko g. 41, LT – 03227 Vilnius, Lithuania, identification number 1399.

Quality:

  Salda UAB activities are in line with the international quality management system standard 

ISO 9001:2015. 

Date                          2019-02-01

Giedrius Taujenis

Director product development

Summary of Contents for KUB T120

Page 1: ...KUB T120 KUB EKO EN MOUNTING AND INSTALLATION INSTRUCTION ...

Page 2: ...product is installed and used If the provided information is unclear or any doubts arise regarding safe installation and operation please contact the manufacturer or represent ative The unit shall be operated only under the below listed conditions It is strictly forbidden to use the unit for non designed purposes or in contradiction to the specified working conditions without written permission of...

Page 3: ...c wall insulation of 25 mm ATTENTION It is necessary to use filter before the fan PURPOSE OF THE DEVICE Fan kitchen box ins is used in ventilation systems to extract air from the room free from metal corroding chemicals aggressive substances for zinc plastic rubber hard sticky and fibrous particles Fan box insulated is designed for ventilation and conditioning systems to supply extract to from a r...

Page 4: ...erature Co 40 40 40 40 40 40 min ambient temperature Co 40 40 40 40 40 40 weight kg 33 55 62 66 98 138 motor protection class IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 wiring diagram 1 22 1 22 1 1 22 1 22 3 1 Speed is controlled only with the frequency inverter Motors sandard IE2 2 The provided technical data is by using 1 el connection scheme Using 2 el connection scheme technical data will be differen...

Page 5: ...rn the impeller by hand MECHANICAL CONECTION Installation works shall be performed only by trained and qualified personnel Unit shall be installed firmly and tightly to ensure safe operation Do not connect the elbows in vicinity of the connection flanges of the unit The minimum distance of the straight air duct between the unit and the first branch of the air duct in the suction air duct must be 1...

Page 6: ...otection devices of the motor Before start up of the fan make sure that the above instructions of safety and installation are applied Upon start up of the unit make sure that the motor rotates evenly without vibration and outside noise Upon start up of the unit make sure that the air flow generated by the unit matches the direction s of air indicated on the casing The current used by the motor sha...

Page 7: ...hermal protection was activated Find the cause for motor overheating and eliminate it The fan motor with thermo contact protection stops because of overheating and external protection is activated Allow the motor to cool down for 15 20 minutes Correct the cause for motor overheating Switch the fan again The motor does not switch on again Disconnect the supply voltage Ensure that the impeller is no...

Page 8: ...al output function Ready to run 0 Not ready 1 Digital output auxiliary voltage Digital input output common Output frequency Speed reference 0 10 V Analog input circuit common Two wire sensor transmitter Analog input circuit common Output frequency 0 20 mA Analog output circuit common Signal cable shield screen Reference voltage Relay output 1 No fault Fault 1 Embedded Modbus RTU EIA 485 L1 L2 L3 1...

Page 9: ...l output function Ready to run 0 Not ready 1 Digital output auxiliary voltage Digital input output common Output frequency Speed reference 0 10 V Analog input circuit common Two wire sensor transmitter Analog input circuit common Output frequency 0 20 mA Analog output circuit common Signal cable shield screen Reference voltage Relay output 1 No fault Fault 1 Embedded Modbus RTU EIA 485 L1 L2 L3 1 ...

Page 10: ...ė UAB SAL Lapas Raidė Data Para as Dok Nr Lapas Keit Ventiliatori jungimas 1 3 5 2 4 6 TK TK PE PE L1 L2 L3 TK TK PE L3 L2 L1 U1 V1 W2 U2 3xNC 140 C 500 V AC 2 5 A L1 L2 PE TK TK W1 L3 V2 3f 400V 1 3 5 2 4 6 TK TK PE PE L1 L2 L3 TK TK PE L3 L2 L1 U1 V1 W2 U2 L1 L2 PE TK TK W1 L3 V2 3f 230V 3xNC 140 C 500 V AC 2 5 A KUB 3 KUB 4 KUB 2 1f 230V 1 3 2 4 TK TK PE PE L1 L2 TK TK PE N L U1 V1 W2 U2 NC 140...

Page 11: ...1 52 2 98 SFPint W m3 s N A N A N A N A N A N A Face velocity m s 0 0 0 0 0 0 Normal external pressure Pa 580 422 493 448 494 600 Internal pressure drop of ventilation compo nents Pa N A N A N A N A N A N A Static efficiency of fans used in accordance with Regulation No 327 2011 57 8 48 4 52 1 49 7 54 51 8 Declared maximum external leakage 1 1 1 1 1 1 Casing sound power level Lwa dB A 76 57 59 62 ...

Page 12: ...ent and risk reduction LST EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 Household and similar electrical appliances Safety Part 1 General requirements LST EN 60529 Degrees of protection provided by enclosures IP code LST EN 60034 5 Rotating electrical machines Part 5 Degrees of protection provided by the integral design of rotating elec...

Page 13: ... the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors or inaccurate information is found as well as after improving the apps and or the devices Such changes will be included in the new issues of the technical passport All illustrations are just for inform...

Page 14: ...14 KUB T120_KUB EKO v2019 04 ...

Page 15: ... 15 KUB T120_KUB EKO v2019 04 ...

Page 16: ...AN000151 UNIT S MAINTENANCE TABLE Product name lot number Instalation Interval Date Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product label At least NOTE The purchaser is required to fill in the Product maintenance table ...

Reviews: