background image

| EN 

KF T120_KF T120 EC v2019.04

SYMBOLS AND MARKING

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

1

4

5

2

6

3

Figure 1.1 - Technical label

1 - Logo; 2 - Product code (SKU); 3 - Product name; 4 - Technical data; 5 - Production place; 6 - Lot number and production date.

Techninis

lipdukas

XXX GAMINIO  PA VADINIMA S

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

Weight

/

xxx/xx VAC/Hz

x.xx A

x.xx kW

IP xx

xx kg

Made in Šiauliai, Lithuani a

FAN000040

BN:xxxxxx

2019/01/01

Techninis

lipdukas

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

Product name

Nominal voltage frequency

Max.current

Max.power consumption

Protection class

/

000 0 VAC

00.00 A

0.00 kW

IP 00

/ 0

/Hz

Made in Šiauliai, Lithuania

SKU000000

LN: LN000000      2019.01.01

Figure 1.2 - KF T120 technical lable place

Figure 1.3 - Indication for air flow direction.

SAFETY INSTRUCTIONS AND WARNINGS

Warning – pay attention

Additional information

GENERAL INFORMATION

• It is necessary to comply with labor safety regulations .

• Prior to the installation of the device it is necessary to read all the material presented in this document.

• The device installation can be performed only by trained and qualified staff, familiar with this type of equipment installation, verification, mainte

-

nance and required tools for installation works.

• Make sure that all the warning signs on the fan are complete and legible.

• The device can only work under following conditions.

• It is strictly prohibited to use the device not for its purpose or not under provided working conditions without receiving a written permit from the 

manufacturer or its representative.

• In the event of failure, it must be reported to he manufacturer or its representative with the description of the failure and provide data on product 

label.

• In the event of a failure, it is prohibited to repair, disassemble the device without a written consent from the manufacturer or its representative.

SAFETY PRECAUTIONS

• Do not use this device for other purposes than described in this manual.

• Do not disassemble or modify the unit in any way which may lead to mechanical failure or injury.

• Use special clothing and be careful while performing maintenance and repair jobs – the unit’s and its components’ edges may be sharp and 

cutting.

• Do not wear loose clothing that could be entangled in to operating unit.

• Do not place fingers or other foreign objects through inlet or exhaust guards or into connected duct. If a foreign object enters the unit, immedi

-

ately disconnect power source. Before removing object, make sure that any mechanical motion has stopped, the heater has cooled down and the 

restart is not possible.

• Do not connect to any other power source than indicated on the model label.

• Do not place or operate unit on unsteady surfaces and mounting frames.

• Mount the unit firmly to ensure safe operating.

• Never use this unit in any explosive or aggressive elements containing environment.

• Do not use the unit if external connections are broken or damaged. If there are any defects, stop operating the unit and replace the damaged 

parts immediately. That can be performed only by qualified electrician.

Summary of Contents for KF T120 160-4 L3

Page 1: ...KF T120 KF T120 EC EN MOUNTING AND INSTALLATION INSTRUCTION...

Page 2: ...ly by trained and qualified staff familiar with this type of equipment installation verification mainte nance and required tools for installation works Make sure that all the warning signs on the fan...

Page 3: ...548 407 250 196 500 29 225 4L3 161 131 537 305 253 250 250 80 50 597 456 277 222 500 34 250 4L3 170 146 577 342 278 315 315 90 50 651 500 290 236 620 44 280 4L3 180 153 626 367 304 315 315 90 50 688 5...

Page 4: ...26 b SP27 b KF T120 160 4 L3 180 4 L3 200 4L3 225 4L3 phase voltage 50 Hz VAC 3 400 50 3 400 50 3 400 50 3 400 50 power kW 0 18 0 29 0 54 0 92 current A 0 57 1 0 1 44 1 72 speed min 1 1310 1340 1390 1...

Page 5: ...er flange 2 Hinges 3 Housing 4 Anti vibration feet 5 Connection Ring 6 Fan 7 Fat chutes with a plug 1 2 8 Switch 9 Roof 10 Engine 11 Electrical connection box 12 Feet 13 Panel bushings 14 Handle Avail...

Page 6: ...STORAGE All units are packed in the factory to withstand regular conditions of transportation Upon unpacking check the unit for any damages caused during transportation It is forbidden to install dam...

Page 7: ...T120 EC Control Accessories 1 MTP010 regulator 2 Stouch panel 3 Stouch S 1141 Domestic use installed filters box For industrial use filters installed extractors Exhaust air Kitchen hood AB AGO ALU Mo...

Page 8: ...tor cools down and connected capacitors when used discharge Ensure that the fan and installed parts and accessories are firmly and tightly installed Carefully clean the impeller to avoid changing the...

Page 9: ...rical connection box The fan has to be connected according to the electric scheme which is described in this document and is shown under the electricity connection switch cap Before turning on it is n...

Page 10: ...L3 2 1 1 2 1 2 2 1 3 2 1 4 2 1 5 2 W1 gr ye W1 black W1 brown W1 grey W3 1 W3 2 W2 1 W2 2 W2 3 PE 1 L1 2 L2 3 L3 3 NC 2 COM 4 Ain1U 0 10V 3 GND 5 10V M1 SP27 b Black 0 5 Black 0 5 Black 0 5 Black 0 5...

Page 11: ...6 PE 1 PE 2 1 2 3 4 5 6 F2 L3 1 2 3 4 5 6 K2 L3 L1 L2 1 2 3 4 5 6 F2 K K2 1 2 3 4 5 6 Q2 1 2 3 4 5 6 PE PE 1 L2 2 L2 1 PE 2 PE SP27 b 1 L1 2 L1 N N With speed controller SMT D 4P EL which allows to se...

Page 12: ...4 PE L1 N K1 A1 A2 K1 1 2 3 4 F1 1 2 10V 1 5 2 1 L1 2 1 1 2 1 2 2 1 3 2 1 4 2 1 PE 2 1 N 2 PE N L1 GND NC COM SP26 b SP25 b 0 10V PE Q1 1 2 3 4 5 6 Vout GND SMT D 4P EL Vin max 1 1mA GND 1 2 3 4 N L1...

Page 13: ...e the launching Make sure that all the bolts and nuts are tightened before the launching MAINTENANCE SAFETY REQUIREMENTS Installation works can only be performed by trained and qualified personnel The...

Page 14: ...balance ant the specialized company Adhesions on the impeller Clean carefully rebalance if necessary Material decomposition on the impeller due to aggressive material conveyed Contact the manufacturer...

Page 15: ...e electrical connection according presented connection scheme Temperature indicator has responded Allow the motor to cool down find and elim inate the cause release reactivation lock if applicable Ele...

Page 16: ...ment and risk reduction LST EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 Household and similar electrical appliances Safety Part 1 General...

Page 17: ...the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors o...

Page 18: ...18 KF T120_KF T120 EC v2019 04...

Page 19: ...19 KF T120_KF T120 EC v2019 04...

Page 20: ...000211 UNIT S MAINTENANCE TABLE Product name lot number Instalation Interval Date Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product l...

Reviews: