Salamander EZ-Touch Manual Lift Wall Mounts - EZ1/MS85/ML209
501-764 [12.22] page 4 of 9
Mounting EZ-Touch Mount Body to Wall
Unpack the EZ-Touch and remove the plastic cover and two foam blocks.
Locating your mount
WOOD CONSTRUCTION:
locate two framing studs (minimum of 16” (405 mm) apart) at the desired location using a stud
finder device.
MASONRY:
a minimum width of 16” (405 mm) is required between fasteners.
Packing Foam
Block (2x)
Plastic Cover
Plastic Cover
Packing Foam
Block (2x)
Remove Plastic Cover and Foam Blocks
Installation of EZ1/MS85/ML209 Mount Body
Prepare Mounting Site
The EZ-Touch was designed to be installed on a 16” on center 2” x 4” wood stud, or metal studs, using
high-quality hollow wall anchor installed in the center of the stud
or a solid concrete wall.
WARNING: INSTALLING THE MOUNT IN UNDERRATED OR DAMAGED CONCRETE CAN LEAD TO
SERIOUS INJURY OR DAMAGE TO PRODUCT! When installing into concrete only install the mount in a
solid concrete wall made of 2500 PSI (17.3 MPa)
or stronger concrete. Never install the mount into cracked, chipped or flaking concrete.
WARNING: IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! It is the installers responsibility to make sure the structure to which
the EZ-Touch is being installed is capable of supporting three times the combined weight of the EZ-Touch
and all
attached equipment is not to exceed the following weight capacities:
EZ1/MB16/152: 90-152lbs / 40-69kg