SKELECT07 ELECT & MECH
WARNING! ENSURE PUMP IS ISOLATED FROM
ELECTRICITY AND WATER SUPPLY. IF IN
DOUBT CONSULT A COMPETENT
TRADESMAN.
Pump should be serviced in horizontal
position with couples disconnected and water
and electricity supply isolated.
DO NOT RUN PUMP DRY. ALLOW WATER TO
FILL PUMP TO LUBRICATE SEALS BEFORE
STARTING. CHECK FOR LEAKS DURING TEST
BEFORE BEING SATISFIED PUMP IS OK
PLEASE NOTE:
By using the parts included in this pack to repair your pump, you will
be invalidating any warranty you have on the pump.
Returns:
If you need to return this pack for any reason please ensure the
original packaging and these instructions leaflets are returned also.
If you have any questions or queries regarding this spares pack or
any other pump related questions please contact us.
UK:
Salamander Pumped Shower Systems Limited
Unit 2c, Colima Avenue Enterprise Park West
Sunderland SR5 3XE
Tel: 0191 516 2002
Email: [email protected]
Eire:
MTA agencies Ireland Fearn House,
Unit 4 Jamestown Business Park
Jamestown Road Finglas,
Dublin 11
Tel:
+
353 (0)1 864 3363
Email: [email protected]
Salamander Pumps Shower Systems Limited
Unit 2c Colima Avenue, Enterprise Park West,
Sunderland, SR5 3XE
Telephone:
0191 516 2002
Facsimile:
0191 548 4445
Email:
www.salamanderpumps.co.uk
Instructions
VIDEO
LINK:
INTRODUCTION
CT HUXTRA/CT FORCEU/BathroomU
(All Universal Variants)
Tools required :
•
PZ2 Screwdriver
•
7mm Deep Socket
•
Long nose Pliers
•
Snips
•
7 mm OE Spanner
•
M6 Allen bit/Wrench
•
2mm Flat Screwdriver
Parts in Service kit:
•
Float- PFLOAT(26) x 2
•
NRV - CNRVPL01 (3) x 2
•
Hall effect sensor HE - EHALLE05 (19) x 2
•
Cable Tie- FCABLE01(22) x 2
•
Interface -EPCBUN05 (5) x 1
•
Vessel Washer - F washe06 - (25) x 1
•
JB Lid Screw- FScrew11 - (8) x 3
•
M6 x 20 SS Cap Screw -FBOLTM13- (21)x6
•
M6 Spring Washer- FWASHE03 -(20) x 6
•
O Ring 59.6mm x 2.4mm- SORING 17- (18) x 2
(Blue) EPDM
•
Filter washers (30) x 2
•
Rubber Flat washers (29) x 2
Document SSI.10 December15. Issue 1