background image

SAL National Pty Ltd. 40 Biloela Street Villawood NSW 2163 ABN 21 633 189 474

Copyright SAL V12 FEB 2020  |  

www.sal.net.au  

 |  Page 3 of 3

14. Warranty – In accordance with SAL’s standard terms and conditions of sale, SAL warrant this product to be free from defects in materials and or workmanship for a 

period as stated below for goods not subject to incorrect installation, maintenance, operation, mishandling, environmental, unauthorised modifications or electrical 

operating conditions outside the nominated product specification as detailed in these installation instructions. The benefits to you given by this warranty are in addition to 

other rights and remedies you have under law. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a 

replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or 

replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Warranty term – Residential usage (60) months, Commercial usage (

60

) months, Replaceable Lamps (where supplied) (12) months and Lithium batteries where supplied 

(24) months from date of purchase. For New Zealand, please refer to www.sal.co.nz for warranty conditions and service.

How to make a claim?

Step # 1  Within 30 days of the fault discovery, please contact the original place of the SAL product purchase during standard (local) business hours, with the following 

information (a) proof of purchase (b) description and quantity of the claimed fault (c) address of installation. (d) operating hours of the product.

Step # 2 – It is then the responsibility of the original place of product purchase to report the matter to SAL aftersales;

NSW  | ACT   

- SAL National Pty Ltd, 40 Biloela Street Villawood NSW 2163

|  P # 02 9723 3099

QLD 

- SAL National Pty Ltd, 36 Whitelaw Place Richlands QLD 4077

|  P # 07 3879 5999

VICT  | TAS   

- SAL National Pty Ltd, 46-48 Keys Road Moorabbin Victoria  3189

|  P # 03 9532 3168

SA | NT 

- SAL National Pty Ltd, Unit 1, 9 Alfred Avenue, Beverley SA 5009

|  P # 08 7084 1958

WA 

- SAL National Pty Ltd, 29 Beringarra Av Malaga WA 6090 

|  P # 08 9248 7458

NZ  

- Hamer, 130 Bush Road, Albany, Auckland, 0632 

|  P # 0800 239 239

Step # 3 - Upon review of your claim and if the product is required to be returned to SAL for technical evaluation, then at the owners expense the product must be 

returned to SAL as per the above nominated locations.

Step # 4 - Pending the evaluation, the claim will be validated resulting in the product being repaired or replaced with the same or best equivalent product at the 

discretion of SAL, or rejected if the product fault was found to be caused by conditions beyond the responsibility of SAL warranty obligations.  Consideration of 

installation, product removal, return freight and or testing fees are not the responsibility of SAL.

• The connected load does not operate:

a. Check if the connected power source and load is correct.
b. Check if the settings of connected load correspond to ambient light.

• The sensitivity is poor:

a. Please check if there is any hindrance in front of the detector to affect it

to receive the signals.

b. Check if the ambient temperature is too high.
c. Check if the signal source is in the detection field.
d. Check if the installation height corresponds to the height required

in the instructions.

e. Check if the moving orientation is correct.

• The sensor does not turn off the connected load automatically:

a. Check if there is continual signal in the detection field.
b. Check if the time delay is set to the maximum position.
c. Check if the power corresponds to the instructions.

TROUBLE SHOOTING:

SENSOR DETECTION RANGE:

• Avoid pointing the sensor towards objects with highly reflective surfaces,
such as mirrors etc.
• Avoid mounting the sensor near heat sources, such as heating vents, air
conditioning units, light etc.
• Avoid pointing the sensor towards objects that may move in the wind,
such as curtains, tall plants etc.

INSTALLATION ADVICE - As the sensor responds to changes in temperature,
avoid the following situations:

5° tilt

2.5m

Max.18m

Max.18m

1. Turn the TIME dial anti-clockwise to the minimum (-).
2. Turn the SENS dial clockwise to the maximum (+).
3. Turn the LUX dial clockwise to the maximum (+).
4. Note: when testing in the daylight, please turn LUX dial to (Max) position,
otherwise the sensor will not operate.
5. Switch on the power; after Warm-up 30sec, the sensor will commence operating.
6. When the sensor receives the signal, the lamp will activate, whilst there is no
movement detected, the connected load will cease operating within 10sec.
7. Turn the LUX dial to the minimum (-). When the ambient light is MORE than 10LUX,
the sensor will not activate the load. When the ambient light is LESS than 10LUX
(darkness), if a movement is detected, the sensor load will commence operating.
if no movement detected, the sensor load will cease operating within 10 sec.

TEST AND COMMISSIONING:

TIME LUX SENS

Reviews: