background image

10

1. Dismantle the mounting frame from the heating 

panel by releasing the two spring clips.

6. Push the heating panel onto the frame until you hear 

an audible click from the spring clips.

5. Hinge the heating panel recess onto two clips of the 

mounting frame. Make sure that the power is switched 

off; then connect the panel to the power mains using a 

terminal block.

4. Mount the frame by screwing it into the ceiling with 

the enclosed screws.

2. Place the mounting frame onto the intended location 

of the heating panel and mark the frame anchoring 

points with a pencil.

3. Drill holes of adequate diameter in the marked 

anchoring points and insert the appropriate anchoring 

material (wall plugs).

MOUNTING

Summary of Contents for Ecora 150

Page 1: ...TOPNÝ PANEL HEATING PANEL AL NÁVOD NA POUŽITÍ strana 2 6 INSTRUCTION MANUAL page 7 11 ...

Page 2: ...od poškozen musí být nahrazen výrobcem jeho servisním technikem nebo podobně kvalifikovanou osobou aby se zabránilo vzniku nebezpečné situace Topný panel je určen pro instalaci ve výšce minimálně 1 8m nad podlahou Některé části tohoto výrobku mohou být velmi horké a způsobit popálení Tento spotřebič není vybaven zařízením pro kontrolu teploty v místnosti Nepoužívejte tento topný panel v malých mís...

Page 3: ...i dvou osob Instalaci musí být prováděna s přívodním kabelem odpojeným od elektrické sítě dle kapitoly Montáž Topný panel je možné montovat na podklady třídy reakce na oheň A1 A2 B C D Rozměry jednotlivých modelů jsou uvedeny v následující tabulce POPIS VÝROBKU i A A C B D TYP PŘÍKON W A mm B mm C mm D mm Ecora AL 80 80 410 230 181 115 Ecora AL 150 150 810 230 568 115 Ecora AL 200 200 510 510 277 ...

Page 4: ...odič L fáze Modrý vodič N střední pracovní vodič Žlutý vodič PE uzemnění Panel nesmí být umístěn těsně nad elektrickou zásuvkou V případě poškození přívodního kabelu je potřeba topný panel vyřadit z provozu Z topného panelu je potřeba pravidelně odstraňovat prach vlhkých hadříkem bez saponátu či rozpouštědla případně s použitím vysavačem Prach je nutné odstranit vždy před zahájením topné sezóny Bě...

Page 5: ... závěsného rámu za drážku panelu Ujistěte se že je vypnut přívod elektrického proudu a proveďte zapojení do elektrické sítě přes svorkovnici 4 Přiložte závěsný rám a přišroubujte jej přiloženými vruty 2 Přiložte závěsný rám na místo kde bude topný panel umístěn a tužkou vyznačte místa pro uchycení závěsného rámu 3 Vyvrtejte označené otvory příslušného průměru vložte kotvící materiál MONTÁŽ ...

Page 6: ... rámu 4 Nechte panel viset za panty závěsného rámu Odpo jte přívodní kabel ze svorkovnice 2 Přitlačte topný panel lehce směrem ke stropu a prostřednictvím plochého šroubováku nebo pinzetových kleští uvolněte v drážce rámu planžetovou pružinu za její zobáček v drážce rámu 3 Stejný postup opakujte také u druhé planžetové pružiny a poté odklopte topný panel DEMONTÁŽ 230 V ...

Page 7: ...nnection is damaged it must be replaced by the manufacturer the manufacturer s service technician or a similarly qualified individual to prevent any risks The heating panel is designed to be installed at a height of at least 1 8 m above floor level Some parts of this product may be very hot and cause burns This appliance is not equipped with a room temperature control device Do not use this heatin...

Page 8: ... of two people The installation must be carried out with the connection cable disconnected from the power source as described in the Assembly chapter The heating panel may be installed on surfaces with a Class A1 A2 B C or D fire resistance rating The dimensions of the models are listed in the table below PRODUCT DESCRIPTION i A A C B D TYPE POWER W A mm B mm C mm D mm Ecora AL 80 80 410 230 181 1...

Page 9: ...damp cloth without any detergent or solving agent or with a vacuum cleaner Dust must always be removed prior to starting the heating season The heating panel must be cold and disconnected from the power source during maintenance During the first operation of the heating panel or the first operation in a given heating season heat the panel gradually and make sure the heated room is well aired Depen...

Page 10: ...ing frame Make sure that the power is switched off then connect the panel to the power mains using a terminal block 4 Mount the frame by screwing it into the ceiling with the enclosed screws 2 Place the mounting frame onto the intended location of the heating panel and mark the frame anchoring points with a pencil 3 Drill holes of adequate diameter in the marked anchoring points and insert the app...

Page 11: ... frame 4 Leave the panel suspended in the mounting frame hinges Disconnect the connecting cable from the terminal block 2 Push the heating panel gently towards the ceiling and release the spring clip ridge from the recess of the panel using a flat tip screwdriver or forceps 3 Repeat the procedure with the second spring clip and then swing the heating panel down DISMOUNTING 230 V ...

Page 12: ...SAKUTUS CZ a s Dražice 256 391 31 Dražice CZECH REPUBLIC info ecora cz www ecora cz Compliant ...

Reviews: