![Sakura Seiki Tissue-Tek Glas g2 Supplement Manual Download Page 5](http://html.mh-extra.com/html/sakura-seiki/tissue-tek-glas-g2/tissue-tek-glas-g2_supplement-manual_801603005.webp)
AI0-IF-025-00
3/9
P. 4.11
End of
Coverslipping
-
Add a caution when removing the storage rack.
When removing the storage rack, be careful not to tilt the storage rack
in the direction of the cut. Doing so may cause the slide to fall.
P. 4.14
Coverslipped
condition
-
Add measures to be taken when air bubbles enter.
If air bubbles still enter after taking the above measures, there may be
an abnormality in the discharge path of the inclusion agent. In such
cases, contact our support line or your distributor.
P. 5.1
Inspection Methods
and Cleaning
-
Add a caution about glass fragments during cleaning.
Be careful of glass fragments when cleaning.
P. 5.2
Care of the
Instrument
-
Add "Cleaning of the basket."
Clean the basket with water or neutral detergent. If the solution
adheres to the instrument and the color or stain is difficult to remove,
soak the instrument in a commercial chemical cleaner for staining
solution or bleach cleaner (both concentrations are as specified by the
commercial product), and then wash it with a neutral detergent. Also,
stains may not be completely removed even after cleaning.
-
Change the statement of Carbon filter replacement frequency to
the following.
Activated carbon filter: Replace the carbon filter with a new one after
2 weeks as a guide (the number of processed slide glasses: about
3000).
* If the instrument is connected to an exhaust system of the facility,
periodic replacement is not needed, but they should be checked
periodically and replaced if necessary.
-
Add "Expiration date of consumables" section.
Make sure that the consumables are used within the expiration date.
- Slide finger: Replace the slide finger when it is damaged or after 2
years as a guide.
- Cover glass suction pad: Replace the pad with a new one when it is
damaged or after one year as a guide.
- Cover glass suction pump diaphragm: Replace with a new one
every year as a guide.