5-003
VIBRATOR
Part name and number in order of its removal
Q’ty
Remarks
1 : Safety cover
1
Remove the four M6 × 12 bolts (2).
3 : Safety guard
1
Remove the two M12 × 25 bolts (22) and the two M12 × 30 bolts (4).
12 : Belt cover
1
Remove the four M8 × 35 bolts (11).
13 : V-belt
1
WARNING
Be careful not to get your hands caught in the belt.
14 : Centrifugal clutch
1
Refer to the 2-1-1. Removal of Centrifugal clutch .
17 : Pulley
1
Refer to the 2-1-2. Removal of Pulley.
15 : Cover
1
Remove the two M8 × 25 bolts (9) and the four M8 × 20 bolts (8).
5 : Engine
1
Remove the M10 × 20 bolt (6) and the engine drain hose (7).
Remove the four M8 × 35 bolts (21).
20 : Base
1
Remove the M8 × 30 bolt (23) and the band (25).
Disconnect the hydraulic hose (24).
(NOTE)
• Attach a plug to the separated connection.
Remove the four M12 × 25 bolts (16).
18 : Vibrator assembly
1
Remove the four M16 × 160 bolts (19).