3-003
INSPECTION AND MAINTENANCE
1-6. Spark Plug
Remove the spark plug to clean off carbon deposit on the plug.
Adjust electrode gap to between 0.7 mm (0.028 in.) and 0.8 mm
(0.031 in.).
Plug : BPR6ES (NGK)
1-7. Hydraulic Oil
1) Put the handle at vertical position to remove the oil plug.
Check that the oil is filled up to a level that is almost
over
fl
ows out of the port.
If it is found insuf
fi
cient, replenish the speci
fi
ed hydraulic oil.
2) Replacement of hydraulic oil are to be carried out after 500
hours of initial operation and every 1000 hours of operation
thereafter.
Speci
fi
ed oil quantity (when in replacement):
0.17 L (0.045 gal.)
•
PF120-03004
PF120-03005
Oil plug
PF120-03006
Summary of Contents for PF120