4. UNPACKING
4.1 ASSEMBLY PARTS
After you receive the SAJ grid-tie solar inverter, please check if there is any
damage on the carton. Also, please check the inside completeness and for any
visible external damage on the inverter or any accessories. Contact your dealer
if anything is damaged or missing.
Object
Description
Quantity
A
B
D
E
F
H
I
1
1
2
6
6
1
1
SAJ grid-tie solar inverter
Rear panel
RS485 connector
(
if attached)
M6×50 Expansion screw
Expansion tube
M4×12 Cylinder head screw and Lock washer
(Sununo-TL1.5K/2K/3KB/4KB)
M5×12 Cylinder head screw and Lock washer
(Sununo-TL3KA/4KA/5K, SU3KMTLI, SU4KMTLI,SU5KMTLI)
User manual, including installation guide
Warranty card
C
4
G
Figure 4.1
DC connector (for Sununo-TL3KB/4KB/3KA/4KA/5K,
SU3KMTLI, SU4KMTLI, SU5KMTLI)
1 sets
2 sets
11
A
B
C
D
E
F
G
H
I
*
**
Here indicastes there is another unit [VA] of these data which is applied to C10/11.
Sununo-TL5K/4KA/3KA has different dimensions for enclosure as
SU5KMTL1
、
SU4KMTL1
、
SU3KMTL1,detail see table documents.
DC connector (for Sununo-TL1.5K/2K)
Input (DC)
Max. DC Power [W]
Max. DC Voltage [V]
MPPT Voltage Range [V]
MPPT Voltage Range[V](Full Load)
DC Nominal Voltage [V]
Start Voltage [V]
Min. DC Voltage [V]
Max. DC Current Input A/Input B[A]
Number of DC Connection Sets
Number of MPP Trackers
DC Switch
Output (AC)
Rated AC Power [W]
Max. AC Power [W]
Rated AC Current [A]
Max. AC Current [A]
Norminal AC Voltage/Range
Grid Frequency/Range
Power Factor(cos φ)
AC Current Distortion (THD)
Consumption at Night [W]
Consumption at Standby [W]
Efficiency
Max. Efficiency
Euro Efficiency (at 360Vdc)
MPPT Accuracy
Protection
Internal Overvoltage Protection
DC Insulation Monitoring
DC Side Varistors
Direct Current Monitoring
Ground Fault Current Monitoring
Grid Monitoring
AC Short Current Protection
Thermal Protection
Anti-island protection monitoring
Interface
AC Connection
DC Connection
LCD Display
Display Language
Datalogger & Communication
General Data
Isolation
Operating Temperature Range
Cooling Method
Ambient Humidity
Site Altitude above Sea Level
Noise Emission dBA)
IP Protection
Mounting
Dimensions (WxHxD) [mm]
Weight [kg]
Standard Warranty (Year)
Safety Class Compliance
EMC Compliance
(
Type
5200
550
125-440
200-440
360
150
100
16 / 16
2
2
Optional
5000
5000
21.7
25
220V, 230V, 240V/180V-280V
50Hz, 60Hz/±5Hz
>0.99 [full load]
< 2%
<0.2
6
97.71%
97.1%
>99.5%
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
AFD
Terminals
MC4/H4
LCD(16x2 Characters
Backlight) & LED(3 Lights)
Multi Language
2*RS485(Standard)
Wi-Fi/Ethernet(Optional)
Transformerless
-25°C to +60°C [45°C to 60°C with derating ]
Natural Convection
0% to 98% Non-condensing
Up to 2000m
<40
IP65 [Indoor or Outdoor Installation]
Rear Panel
525*425*190
26
5 / 10 /15/20/25 [Optional]
,
,
AS3100
,
IEC62109-1
,
IEC62109-2
EN61000-6-2
,
EN61000-6-3
,
EN61000-3-2
,
EN61000-3-3
Sununo
-
TL5K
VDE 0126-1-1/A1
,
VDE 4105
,
G83
,
G59
,
RD1699
,
C10/11
,
AS4777.3
,
EN50438
,
CGC/CF004
Grid Protection Compliance