User
Manual
User
Manual
9
10
Input (DC)
Max. DC Power [W]
Max. DC Voltage [V]
MPPT Voltage Range [V]
MPPT Voltage Range[V](Full Load)
DC Nominal Voltage [V]
Start Voltage [V]
Min. DC Voltage [V]
Max. DC Current Input A/Input B[A]
Number of DC Connection Sets
Number of MPP Trackers
DC Switch
Output (AC)
Rated AC Power [W]
Max. AC Power [W]
Rated AC Current [A]
Max. AC Current [A]
Norminal AC Voltage/Range
Grid Frequency/Range
Power Factor(cos φ)
AC Current Distortion (THD)
Consumption at Night [W]
Consumption at Standby [W]
Efficiency
Max. Efficiency
Euro Efficiency (at 360Vdc)
MPPT Accuracy
Protection
Internal Overvoltage Protection
DC Insulation Monitoring
DC Side Varistors
Direct Current Monitoring
Ground Fault Current Monitoring
Grid Monitoring
AC Short Current Protection
Thermal Protection
Anti-island protection monitoring
Interface
AC Connection
DC Connection
LCD Display
Display Language
Datalogger & Communication
General Data
Isolation
Operating Temperature Range
Cooling Method
Ambient Humidity
Site Altitude above Sea Level
Noise Emission dBA)
IP Protection
Mounting
Dimensions (WxHxD) [mm]
Weight [kg]
Standard Warranty (Year)
Safety Class Compliance
EMC Compliance
(
Type
Sununo
-
TL3KA
Sununo
-
TL4KA
550
125-440
200-440
360
150
100
2
2
Optional
220V, 230V, 240V/180V-280V
50Hz, 60Hz/ ±5Hz
>0.99 [full load]
< 2%
<0.2
6
>99.5%
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
AFD
Terminals
MC4/H4
LCD(16x2 Characters
Backlight) & LED(3 Lights)
Multi Language
2*RS485(Standard)
Wi-Fi/Ethernet(Optional)
Transformerless
-25°C to +60°C [45°C to 60°C with derating ]
Natural Convection
0% to 98% Non-condensing
Up to 2000m
<40
IP65 [Indoor or Outdoor Installation]
Rear Panel
525*425*175
23
5 / 10/15/20/25 [Optional]
,
,
AS3100
,
IEC62109-1
,
IEC62109-2
EN61000-6-2
,
EN61000-6-3
,
EN61000-3-2
,
EN61000-3-3
3200
15/15
3000
3000
13.0
15.0
97.6%
96.8%
4200
15/15
4000
4000
17.4/16
20.0/16
97.6%
96.8%
Input (DC)
Max. DC Power [W]
Max. DC Voltage [V]
MPPT Voltage Range [V]
MPPT Voltage Range[V](Full Load)
DC Nominal Voltage [V]
Start Voltage [V]
Min. DC Voltage [V]
Max. DC Current Input [A]
Number of DC Connection Sets
Number of MPP Trackers
DC Switch
Output (AC)
Rated AC Power [W]
Max. AC Power [W]
Rated AC Current [A]
Max. AC Current [A]
Norminal AC Voltage/Range
Grid Frequency/Range
Power Factor(cos φ)
AC Current Distortion (THD)
Consumption at Night [W]
Consumption at Standby [W]
Efficiency
Max. Efficiency
Euro Efficiency (at 360Vdc)
MPPT Accuracy
Protection
Internal Overvoltage Protection
DC Insulation Monitoring
DC Side Varistors
Direct Current Monitoring
Ground Fault Current Monitoring
Grid Monitoring
AC Short Current Protection
Thermal Protection
Anti-island protection monitoring
Interface
AC Connection
DC Connection
LCD Display
Display Language
Datalogger & Communication
General Data
Isolation
Operating Temperature Range
Cooling Method
Ambient Humidity
Site Altitude above Sea Level
Noise Emission dBA)
IP Protection
Mounting
Dimensions (WxHxD) [mm]
Weight [kg]
Standard Warranty (Year)
Safety Class Compliance
EMC Compliance
(
Type
Sununo
-
TL3KB
Sununo
-
TL4KB
550
125-440
360
150
100
2
1
Optional
220V, 230V, 240V/180V-280V
50Hz, 60Hz/ ±5Hz
>0.99[full load]
< 2%
<0.2
6
>99.5%
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
AFD
Terminals
MC4/H4
LCD(16x2 Characters
Backlight) & LED(3 Lights)
Multi Language
2*RS485(Standard)
Wi-Fi/Ethernet(Optional)
Transformerless
-25°C to +60°C [45°C to 60°C with derating ]
Natural Convection
0% to 98% Non-condensing
Up to 2000m
<40
IP65 [Indoor or Outdoor Installation]
Rear Panel
450*375*177
21
5 / 10/15/20/25 [Optional]
,
,
AS3100
,
IEC62109-1
,
IEC62109-2
EN61000-6-2
,
EN61000-6-3
,
EN61000-3-2
,
EN61000-3-3
3400
200-440
17
3000
3300
13.0
15.0
97.7%
97.1%
4500
225-440
20
4000
4400
17.4/16
20.0/16
97.7%
97.1%
Remarks: Meet the grid standard AC current per phase not exceeding 16A.
1
1
VDE 0126-1-1/A1
,
VDE 4105
,
G83
,
G59
,
RD1699
,
C10/11
,
AS4777.3
,
EN50438
,
CGC/CF004
Grid Protection Compliance
1
1
Remarks: Meet the grid standard AC current per phase not exceeding 16A.
VDE 0126-1-1/A1
,
VDE 4105
,
G83
,
RD1699
,
C10/11
,
AS4777.3
,
EN50438
,
CGC/CF004
Grid Protection Compliance
Summary of Contents for Sununo-TL Series