AC Short Circuit Current
Protection
Integrated
Thermal Protection
Integrated
Anti-island protection
monitoring
AFD
Interface
AC Connection
Plug-in connector
DC Connection
MC4/H4
LCD/LED Display
LCD (16x2 Characters, Backlight) & LED (3 Lights)
Display Language
English
Datalogger & Communication
RS232 (Standard)/WiFi (Optional)
General Data
Topology
Transformerless
Consumption at Night [W]
<0.2
Consumption at Standby [W]
6
Operating Temperature Range
-25
°
C to +60
°
C (45
°
C to 60
°
C with derating)
Cooling Method
Natural Covection
Ambient Humidity
0% to 98% Non-condensing
Altitude
Up to 2000m (without derating)
Noise [dBA]
<25
Ingress Protection
IP65 (Indoor & Outdoor Installation)
Mounting
Rear Panel
Dimensions (H*W*D) [mm]
454*355*150
454*355*162
Net Weight [kg]
14.8
15.8
Standard Warranty [Year]
5
(
Standard
)
/10/15/20/25
(
Optional
)
Certificates
IEC62109-1/2, IEC61000-6-2/3, IEC61683, IEC60068-2,
IEC62116, IEC61727, PEA/MEA, NRS 097-2-1,
UTE-C-15-712-1, VDE0126-1-1/A1, VDE-AR-N 4105,
AS4777.2, AS4777.3, C-TICK, CQC NB/T 32004, G83-2,
G59-3, NBR 16149, NBR 16150, TF 3.2.1, C10/11
Remark:
1. Meet the grid standard that AC current per phase not exceeding 16A.
2. Meet the VDE - ARN - N 4105 that biggest apparent power of single-phase is