background image

 

                                                                                R5 

Series

 

 

 
 

 

- 52 -

 

goods  fail  to  be  of  acceptable  quality and  the  failure  does  not  amount  to  a  major 

failure. 

1.2 Extension of Warranty 

The purchaser of SAJ inverters (R5 series, Sununo Plus series, Suntrio Plus series, 

Sunfree hybrid series and AC-coupled inverters) should extend the warranty period 

in 18 months from the date of settlement or 30 months from the date of shipment 

from  SAJ  by  providing  the  serial  number  of  the  unit  and  purchased  receipt 

(whichever is shorter). You can purchase the  warranty extension for  10 years, 15 

years, 20 years or 25 years but do not apply the extension beyond the specified date, 

or else your application will be unacceptable. Please refer to the Warranty Extension 

Order Form for more details. 

Once  the  purchase  of  the  warranty  extension  goes  into  effect,  SAJ  will  send  the 

warranty extension certificate to the customer for confirming the extended warranty 

period. 

1.3 Warranty Conditions   

I

f  your  inverter  gets  fault  and  requires  troubleshooting,  please  contact  your 

distributor or dealer directly. Alternatively, feedback briefly to SAJ for logging and 

send your scanned warranty card to SAJ Service Team ([email protected]

by email to process the warranty claim.

 

During the Warranty Period, SAJ only covers the costs of materials, delivery (land 

or sea transportation) and other derived expense, for example custom taxation, when 

you send defective products to SAJ/SAJ distributor or/and SAJ/SAJ distributor send 

refurbished products to you for replacing any product or parts of the product proved 

to be defective in design or manufacture. To claim the warranty under the warranty 

policy  of  SAJ,  you  need  to  supply  us  with  the  following  information  and 

documentation regarding the faulty inverter: 

(1) Product Model No.(e.g. R5-3K-S2) and serial number (e.g. R5S2302G1821E 

00001).   

(2) Copy of the invoice and warranty certificate of the inverter.   

(3) Copy of the installation report and installation date.   

Summary of Contents for R5 Series

Page 1: ...R5 Series 1...

Page 2: ...nd safety Please follow the instructions of this manual so that we can ensure delivery of our professional guidance and wholehearted service Customer orientation is our forever commitment We hope this...

Page 3: ...ION 8 3 1 APPLICATION SCOPE OF PRODUCTS 8 3 2 SPECIFICATION FOR PRODUCT MODEL 9 3 3 OVERVIEW OF PRODUCTS 9 3 4 DATASHEET 10 CHAPTER 4 INSTRUCTIONS FOR INSTALLATION 16 4 1 SAFETY INSTRUCTIONS 16 4 2 PR...

Page 4: ...DUCTION OF HUMAN COMPUTER INTERFACE 36 6 2 MONITORING OPERATION 37 6 3 SETTING REACTIVE POWER CONTROL 44 CHAPTER 7 FAULT CODE AND TROUBLESHOOTING 46 CHAPTER 8 ROUTINE MAINTENANCE 49 INVERTER CLEANING...

Page 5: ...ANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided can result in death or ser...

Page 6: ...be disconnected from the grid and PV generator you must wait for at least five minutes to let the energy storage capacitors completely discharged after disconnecting from power source WARNING The inst...

Page 7: ...heat sink or peripheral surface during or shortly after operation Risk of damage due to improper modifications NOTICE Public utility only The solar inverter is designed to feed AC power directly to th...

Page 8: ...anger of hot surface The components inside the inverter will release a lot of heat during operation Do not touch metal plate housing during operating An error has occurred Please go to Chapter 9 Troub...

Page 9: ...he requirements of public grid and send the AC into the grid Figure 3 1 shows the structural diagram of the typical application system of R5 inverter Figure 3 1 R5 series application Name Description...

Page 10: ...W of inverter for example 4K means 4kW T means three phase 2 represents the inverter has the function of dual MPPT AUS For Australia 3 3 Overview of products The dimensions of R5 series products is sh...

Page 11: ...4000 5000 6000 Max AC Power VA 3300 4400 5500 6600 Rated AC Current A 4 4 5 8 7 3 8 7 Max AC Current A 5 0 6 7 8 4 10 0 Current Inrush A 50 Feedback Current A 0 1 Max AC Fault Current A 24 5 24 5 24 5...

Page 12: ...2 USB RS485 RJ45 Communication Mode Wi Fi GPRS 4G Optional General Data Topology Transformerless Consumption at Night W 0 6 Consumption at Standby W 10 Operating Temperature Range 40 60 45 C to 60 C w...

Page 13: ...10000 Max AC Power VA 8800 9900 11000 Rated AC Current A 230Vac 11 6 13 1 14 5 Max AC Current A 13 4 15 0 16 7 Current Inrush A 60 Feedback Current A 0 1 Max AC Fault Current A 41 41 41 Max AC Over Cu...

Page 14: ...USB RS485 RJ45 Communication Mode Wi Fi GPRS 4G Optional General Data Topology Transformerless Consumption at Night W 0 6 Consumption at Standby W 10 Operating Temperature Range 40 60 45 C to 60 C wi...

Page 15: ...20000 Max AC Power VA 16500 18700 22000 Rated AC Current A 230Vac 21 8 24 7 29 0 Max AC Current A 25 0 28 4 33 4 Current Inrush A 90 Feedback Current A 0 1 Max AC Fault Current A 63 Max AC Over Curren...

Page 16: ...ption at Night W 0 6 Consumption at Standby W 10 Operating Temperature Range 40 60 45 C to 60 C with derating Cooling Method Natural Convection Ambient Humidity 0 100 Non condensing Altitude 4000m 300...

Page 17: ...ropriate installation environment may jeopardize the life span of the inverter Installation directly exposed under intensive sunlight is not recommended The installation site must be well ventilated 4...

Page 18: ...convenience for maintenance please install the equipment at a position in parallel with line of sight When mounting the inverter please consider the solidity of wall for inverter including accessorie...

Page 19: ...alled together the following safety clearance in Figure 4 2 shall be followed for proper ventilation conditions 30CM 50CM 50CM 30CM 30CM 4 2 Installation position 4 4 Mounting Procedure 4 4 1 Mark the...

Page 20: ...given guides drill 3 holes in the wall in conformity with position marked in Figure 4 5 and 4 6 and then place expansion tubes in the holes using a rubber mallet Figure 4 5 Drill holes dimensions of...

Page 21: ...unting position by screws as shown in Figure 4 7 Figure 4 7 Mount the rear panel 4 4 4 Mount the Inverter Carefully mount the inverter to the rear panel as shown in Figure 4 8 and 4 9 Make sure that t...

Page 22: ...re 4 10 and 4 11 anti theft lock could be added to the inverter and hanging panel Diameter of the lock hole is 6 0mm and anti theft lock of which the diameter of lock hook is 5 0mm is recommended User...

Page 23: ...R5 Series 22 Figure 4 11 Install anti theft lock of R5 15K 17K 20K T2 AUS...

Page 24: ...electricity shock When power on the equipment should be in conformity with national rules and regulations The direct connection between the inverter and high voltage power systems must be operated by...

Page 25: ...R5 Series 24 5 2 Specifications for Electrical Interface Figure 5 1 Electrical interface of R5 3K 4K 5K 6K T2 AUS Figure 5 2 Electrical interface of R5 8K 9K 10K T2 AUS...

Page 26: ...Optional B Decompression Valves C DC Input D DRM E RS232 Communication GPRS Wi Fi 4G F Ground Connection G RS485 Communication H AC Output Table 5 1 Specifications for interface Figure 5 3 Electrical...

Page 27: ...6 0 5 3 6 7 Table 5 3 Recommended power grid connecting cable specification If the grid connection distance is too far please select an AC cable with larger diameter as per the actual condition 5 3 1...

Page 28: ...communication module until the error being solved and inverter functioning properly 2 Feed the AC cable through the AC waterproof hole Figure 5 5 Feed cable 3 Connect the cables according to connectio...

Page 29: ...ing port of inverter enclosure in clockwise direction and make sure it is screwed up tightly Fig 5 9 Inverter ground protection 2 Screw off the screws at the AC output wire cover and take out the cove...

Page 30: ...erface protective cover and the locker 5 3 3 External ac circuit breaker and Residual Current Device Please install a 4P circuit breaker to ensure the inverter is able to disconnect from grid safely T...

Page 31: ...R5 8K 9K 10K T2 AUS 32A R5 15K T2 AUS 40A R5 17K 20K T2 AUS 63A Notice Do not connect multiple inverters to one AC circuit breaker Table 5 4 Recommended breaker specification 5 4 DC Side Connection Cr...

Page 32: ...and negative cables with appropriate length yh 1 Positive cable 2 Negative cable Figure 5 14 Connecting cables 3 Feed the positive and negative cables into corresponding lock screws 4 Insert the posi...

Page 33: ...minals of the inverter a click sound should be heard when the contact cable assembly is seated correctly 1 Connection port Figure 5 15 Connect the inverter NOTICE Before inserting the connector into D...

Page 34: ...n Function 1 White orange NC 2 Orange GND_W 3 White green 7V_W 4 Blue NC 5 White blue NC 6 Green NC 7 White brown RS485 A 8 Brown RS485 B Table 5 6 RS485 pin port definition To comply with Australian...

Page 35: ...ode Figure5 17 RS232 pin Pin Number Description Function 1 7V Power supply 2 RS 232 TX Send data 3 RS 232 RX Receive data 4 GND Ground wire Table 5 8 USB pin port definition 1 USB interface could be e...

Page 36: ...able LED indicators will be lit up 4 Inverter is in self testing mode if inverter has met all the grid connecting condition inverter will connect to grid and generate power automatically 5 6 2 Shut do...

Page 37: ...ow Always light on The inverter is just on power B Green Flicker 1 s time The inverter is in the initialization or waiting state Always light on The inverter is in normal on grid state Red Always ligh...

Page 38: ...arch for eSolar O M in App Store and download this App Users using Android system could search for eSolar O M in Google play and download this App For iOS Android system you could visit SAJ official w...

Page 39: ...bile Bluetooth Next step Bluetooth WiFi Cloud 3 Choose next step search for equipment click the Bluetooth name matched with the inverter ex R5 4K T2 00001 4 Connect successfully set country and grid c...

Page 40: ...mobile Bluetooth Next step Bluetooth WiFi Cloud 3 Choose next step search for equipment click the Bluetooth name matched with the inverter ex R5 4K T2 00001 4 Connect successfully set country and grid...

Page 41: ...version Slave board firmware version could be checked Device info Bluetooth R5 4K T2 00001 R5T2043G1815E00001 Inverter model Module SN code Module firmware version Communication board firmware version...

Page 42: ...info Battery information CT1 CT2 CT3 N V N V N V N A N A N A N W N W N W Fig 6 4 Running information 3 Click Power info Current power today energy monthly energy yearly energy total energy could be c...

Page 43: ...evice info Bluetooth R5 4K T2 00001 R5T2043G1815E00001 Datetime 2018 11 10 18 16 00 No Err73 Content XXXX 2 Datetime 2018 11 09 18 16 00 No Err73 Content XXXX 1 Basic info Running info Power info Even...

Page 44: ...n Communication board firmware version Main board firmware version Slave board firmware version could be checked 2 Click Running info PV information voltage and current at PV terminal Grid power infor...

Page 45: ...tive Power Control 6 3 1 Setup Fixed Power Factor mode The characteristic power factor curve for cos P Power response mode varies the displacement power factor of the output of the inverter in respons...

Page 46: ...n during installation You can choose a state regulation compliance with your local grid via eSolar WiFi D module or eSolar O M APP 2 Log in to eSolar O M APP click Local Connection for connection proc...

Page 47: ...L3 High Average Voltage of 10 minutes Master 18 20 22 L1 L2 L3 Over Frequency Master 19 21 23 L1 L2 L3 Low Frequency Master 24 25 26 L1 L2 L3 Grid Lost Error Master 27 GFCI Error Master 28 29 30 L1 L...

Page 48: ...ter 84 PV Input Error Master 86 DRM0 Error Master Table 7 1 Error Code General troubleshooting methods for inverter are as follows Fault Information Troubleshooting Relay Error If this error occurs fr...

Page 49: ...e mentioned are in normal please contact your distributor or call SAJ technical support Grid Lost Error Check the connection status between the AC side of the inverter and the grid if the above mentio...

Page 50: ...tion cables between control board and display board If the above mentioned are in normal please contact your distributor or call SAJ technical support Null line to earth voltage fault Check if connect...

Page 51: ...nd is not required to be returned to your dealer and it must be disposed carefully by an approved collection and recycling facility in your area Chapter 10 Contact SAJ Guangzhou Sanjing Electric Co Lt...

Page 52: ...ears for the R5 series Sununo Plus series Suntrio Plus series Sunfree hybrid series AC coupled inverters starting from the date of shipment from SAJ factory or 60 months 5 years starting from the date...

Page 53: ...ming the extended warranty period 1 3 Warranty Conditions If your inverter gets fault and requires troubleshooting please contact your distributor or dealer directly Alternatively feedback briefly to...

Page 54: ...or out of stock SAJ will provide new model type of inverter or an equivalent value product If the inverter needs to be replaced following assessment SAJ will send a replacement unit immediately The de...

Page 55: ...Warranty Card not being sent back to Distributor Dealer or SAJ Product modified parts replaced or attempt to maintain Changes or attempted repairs and erasing of series number or seals by non SAJ tech...

Page 56: ...evere weather fire etc Any out of pocket costs incurred by Installer Distributor or compensation from electricity production loss are not borne by SAJ in the standard warranty For further information...

Page 57: ...please complete the below forms and send this page to SAJ attached with the Customer s invoice For customer to fill in Name City Country Zip Tel Fax E mail Information on device Device type Serial No...

Page 58: ...R5 Series 57 For installer to fill in Modules used Modules per string No of string Installation company Contractor license number Company City Country Zip Tel Fax E mail Signature Date...

Page 59: ...R5 Series 58...