Saivod TMS158 Manual Download Page 31

GB

31

OPERATING INSTRUCTIONS

 

Water Entering: After fixing all the pipes, then make the cold and 
heat water-blending valve rotate to the high temperature sector 
according to the clockwise direction. And reopen the cold water 
pipe’s water pipe’s water entering valve. At this time, the electric 
water heater’s tank will start to enter the water. Waiting that the 
shower sector of the water exiting mouth is in normalcondition, 
which indicates that the tank has fully filled with water.

Cautions: During the electric water heater is in the normal operating 
procedures, the water-entering valve of the cold water pipe’s mouth-en-
tering sector must be in the open condition from the beginning to the 
end .At this time, the water-entering valve can still make the functions of regulating the 
water-existing mouth section’s flowing strength and weakness. However, the cold and hot 
mixed water valve can only regulate the water temperatures and make the function of clos-
ing the water existing. 

 

Putting through the power: After confirming the tank to be fully filled the water, you can 
make the power source’s plug insert into the outlet and put through the power sources.

 

Hot water operations: After the electric water heater normally works and heats for a 
long period of time, you can use the hot water in the tank, you need to make the cold 
and hot mixed valve rotate with the clockwise direction slowly from the low tempera-
ture to the high temperatures in the closed condition. And adjust it to your proper tem-
perature. At that time, the shower mouth can come out the hot water. After finishing the 
uses, you can turn it to the closed section by the anti-clockwise direction and shut off 
the mixed water valve. 

 

Cautions: When adjusting the water temperature of the water-existing mouth, you don’t 
make the shower directly to the human body; you should test the water temperature 
first to avoid burning to damages.

 

Overheating Protections: Under the condition of putting through the power, but the 
heating pipe won’t heat from the beginning from the end. At this time, it may appear 
the over heat protections (that is to make functions by the double-positional tempera-
ture-limiting protection switch).

 

Automatically balance the temperatures: when the water temperature in the tank reach-
es the set one, it will automatically cut off the power and halt heating. Meanwhile, the 
heating indicator will put out. The electric water heater will be in the temperature-main-
taining condition. When the water temperature in the tank reduces to a certain one, It 
will automatically begin to heat. After reaching the temperature-keeping condition. It 
will circulate to automatically work like these.

OPERATING GUIDES

Temperature setting: According to your required temperature, rotate the temperature-ad-
justing knob by the clockwise direction. You can select to use the heating temperatures 
without grades in the temperature ranges of twenty to seventy-five degrees Celsius from 
closing to the low, medium and high bands or from low to high. 

DAILY AND COMMON MAINTENANCES

 

Frequently checking the connection of power source’s plug and the outlet is in good 
condition. Reliable, whether heating. The plug’s outlet is well connected the ground or 
not.

TMS158.indd   31

2018/3/23   10:09:24

Summary of Contents for TMS158

Page 1: ...TMS158 indd 1 2018 3 23 10 09 21...

Page 2: ...TMS158 indd 2 2018 3 23 10 09 21...

Page 3: ...jugar con el aparato La limpieza y el mantenimiento a realizar por el usuario no deben realizarlos los ni os sin supervisi n Los ni os no deben jugar con el aparato La limpieza y el mantenimiento a re...

Page 4: ...aparato mantenimiento e informaci n sobre el drenado del calentador de agua por favor ver los siguientes cap tulos de este manual de instrucciones Presi ndeagua usonormalenunrangode0 02 0 7MPa TMS158...

Page 5: ...ura de configuraci n 6 Enchufe de nuevo el aparato Si los pasos descritos anteriormente no funcionan la temperatura del interior del termo po dr a continuar siendo demasiado alta En ese caso abra la v...

Page 6: ...as y coloque la manilla de pl stico hacia arriba Deje que el agua salga naturalmente Diagrama 2 Diagrama 1 Diagrama 2 DATOS DE REFERENCIA T CNICA Tensi n Nominal 220 240 V Potencia Nominal 2000W Frecu...

Page 7: ...Despu s utilice un martillo para colocar los soportes de fijaci n de los tornillos en los dos agujeros 4 Ajuste el panel trasero a los soportes mencionados con dos roscas de ST6 0 60 5 Levante el cal...

Page 8: ...los pernos de extensi n firmemente sujetos Evite colocar los en las partes huecas o en las grietas de los ladrillos El enchufe de la fuente de alimentaci n debe de ser de alta calidad monof sico tri p...

Page 9: ...a del agua y cerrar la salida de agua Encender el aparato despu s de comprobar que el dep sito est totalmente lleno en chufe el aparato a la red el ctrica Uso del agua caliente tras el funcionamiento...

Page 10: ...o en direcci n de las agujas del reloj Puede graduar la temperatura entre los rangos de veinte a setenta y cinco grados Celsius acercando las bandas baja media y alta o de alta a baja MANTENIMIENTO Co...

Page 11: ...s bajos de temperatura Ajuste la v lvula para valores de temperatura mayores 3 El termostato no funciona bien Busque a un profesional para que lo repare 4 El tubo del calentador est da ado No sale agu...

Page 12: ...TICA DE CALDEO DE AGUA Y EL CONSUMO ANUAL DE ELEC TRICIDAD CORRESPONDIENTES N A H LOS AJUSTES DE TEMPERATURA DEL TERMOSTATO DEL CALENTADOR DE AGUA EN EL MOMENTO DE SU COMERCIALIZACI N POR EL PROVEEDO...

Page 13: ...as como cualquier otra de fuerza mayor Uso negligente inadecuado o no dom stico como aparatos instalados en peluquer as bares restaurantes hoteles etc La intervenci n o manipulaci n de servicios t cni...

Page 14: ...ou conhecimentos se a eles foi dada supervis o ou instru es no que respeita ao uso do aparelho de uma maneira segura e compreendido os perigos envueltos A limpeza e a manuntan o pelo utili zador n o...

Page 15: ...e descida cont nua Sobre a instala o incluindo informa es de como fixar o equipamento manuten o de uso e informa es sobre como o aquecedor de gua pode ser drenado favor utilizar como refer ncia os ca...

Page 16: ...igura o do Interruptor de Prote o com Limitador de Tempe ratura de N vel Duplo 1 Puxe o plugue de energia 2 Abra a tampa de pl stico na parte inferior canto direito do produto com as ferramentas adequ...

Page 17: ...seguran a pode apresentar determinada temperatura o que uma condi o normal Isso indica que a press o de vazamento est escoando internamente Para escoar o tanque siga os seguintes passos Caso queira es...

Page 18: ...n ticos Evitar luz solar direta chuva vento e evitar batidas 3 Primeiramente fure 2 furos com a furadeira onde o furo seja menor que o di metro da has te da bucha de fixa o Furos com 60mm de profundid...

Page 19: ...8 para conectar tubos Gr fico 7 IMPORTANTE As paredes que forem ser instaladas devem ser s lidas os parafusos devem ser presos firmemente N o deve ser permitido montar em tijolos ocos ou em fendas de...

Page 20: ...ando a sa da de gua estiver fechada Energia Ap s verificar que o tanque est cheio de gua voc pode conectar o plugue na tomada para utilizar o aquecedor de gua el trico Opera es da gua quente Assim que...

Page 21: ...e selecionar a temperatura de aqueci mento sem gradua o de vinte a setenta graus Celsius selecionando as bandas de baixo m dio e alta ou do baixo para o alto MANUTEN ES COMUNS E DI RIAS Cheque frequen...

Page 22: ...te o profissional para efetuar a inspe o 4 Tubo de aquecimento danifi cado gua n o saindo pelo bocal de gua quente 1 Sem fornecimento de gua Aguarde fornecimento de gua 2 Baixa press o no fornecimento...

Page 23: ...RIOR EXPRESSO EM DB 15DB J O AQUECEDOR DE GUA TEM A CAPACIDADE DE FUNCIONAR UNICAMENTE FORA DAS HORAS DE PICO NO K EVENTUAIS PRECAU ES ESPEC FICAS QUE DEVAM SER ADOTADAS DURANTE A MONTAGEM INSTALA O O...

Page 24: ...aos oficiais da marca Corros o e ou oxida o tanto os causados pelo uso e desgaste normal do aparelho como os acelerados por condi es ambientais adversas Uso de acess rios ou produtos consum veis que...

Page 25: ...8 years and above and persons with reduced phys ical sensory or mental capabilities or lack of ex perience and knowledge if they have been given supervision or instruction concerning use of the applia...

Page 26: ...e installation including information about how to fixed the appliance user mainte nance and information about how the water heat er can be drained thanks to refer the below relat ed chapters of this i...

Page 27: ...to be safe The Position resetting Methods of the Double Position Temperature limiting Device 1 Pull down the power source plug 2 Make the plastic lid on the bottom right side of horizontal style the...

Page 28: ...he wa ter entering pipe s outer cover under the safety valve may have a certain temperature This belongs to the normal conditions This indicates that it is internally draining the leakage pressure To...

Page 29: ...oard Pull down left right once to make sure the water heaters is fixed Note 1 The two plug bolt hooks should completely in the wall and at the same height horizon tally 2 The wall installed to should...

Page 30: ...ire which must be installed at the properly high positions and the uneasily water showered damp places This outlet had better be typically used for the electric water heater Diagram 8 When it is in th...

Page 31: ...the shower mouth can come out the hot water After finishing the uses you can turn it to the closed section by the anti clockwise direction and shut off the mixed water valve Cautions When adjusting t...

Page 32: ...acks of tank After finishing uses each time you should make the water in the tank pour out In order to assure the electric water heater to work with efficiencies you had better clean the heating parts...

Page 33: ...al functional Invite the professional to mend it by inspections 4 The heating tube damaged No water coming out at the hot water mouth 1 Halting the tap water Awaiting the tap water to provide the wate...

Page 34: ...K SPECIFIC PRECAUSTIONS WHEN ASSEMBLED IN STALLED AND MAINTAINED SEE THE INSTURCTOIN MANUAL I WHERE THE VALUE OF SMART IS DECLARED AS BEING 1 AN INDICATION THAT THE INFORMATION ON WATER HEATING ENERG...

Page 35: ...nes of the brand Corrosion and or rust caused by the normal wear and tear of the appliance or accelerated by adverse environmental conditions Use of accessories or consumables which are not the origin...

Page 36: ...TMS158 indd 36 2018 3 23 10 09 25...