400V Motor
Put the ON-OFF-Switch on ON. Then put the Star-Triangle-Switch on Y. Wait until the blade
reaches its maximum rotational speed, then turn the Star-Triangle-switch on
∆
.
The direction of rotation is indicated on the blade guard. If the direction of rotation does not
correspond to the direction shown by the arrow, then reverse the motor polarity by turning the phase
inverter inside the male plug with a screwdriver.
Machine dual voltage 230V/400V
Set the 230V/400V switch on the voltage corresponding to the one supplied to your machine. A
wrong voltage choice can damage the electrical equipment of your machine.
The direction of rotation is indicated on the blade guard. If the direction of rotation does not
correspond to the direction shown by the arrow, then reverse the motor polarity by turning the phase
inverter inside the male plug with a screwdriver.
3.4 Water cooling system
Fill the water pan with clean water to approximately 2cm from top (ensure that bottom of pump is
fully immersed in water).
Open water-tap at blade guard (note that handle on water-tap should be in line with water-flow).
Ensure that water is flowing freely in the circuit and is delivered adequately to both sides of the
blade, as insufficient water supply may result in premature failure of the diamond blade.
The water pump must never run without water. Always make sure that there is enough water in the
pan and refill if necessary.
In case of frost, empty the water cooling system from its water.
4 TRANSPORT AND STORING
4.1 Securing for transport
•
Before transporting or lifting the machine, always remove the blade and the conveyor cart and
empty the water pan.
4.2 Transport procedure
If you transport the machine using a fork-lift truck, you have to use EXCLUSIVELY the two fork lift
brackets under the water pan.
4.3 Long period of inactivity
If the machine is not going to be used for a long period, please take the following measures:
•
Completely clean the machine
•
Loosen the drive belts
•
Empty the water system
•
Take the water pump out of the slurry and clean it thoroughly.
The storage site must be clean, dry and at a constant temperature.
Summary of Contents for NORTON CLIPPER CM 501 ME
Page 1: ...CM 501 ME OPERATING INSTRUCTIONS Translation of the original instructions...
Page 2: ...VERS 2017 06 21 CM 501 ME_MAN_EN 2...
Page 4: ...VERS 2017 06 21 CM 501 ME_MAN_EN 4...
Page 23: ...VERS 2017 06 21 CM 501 ME_MAN_EN 23 7 3 CIRCUIT DIAGRAM 230V Motor...
Page 24: ...VERS 2017 06 21 CM 501 ME_MAN_EN 24 115V Motor...
Page 25: ...VERS 2017 06 21 CM 501 ME_MAN_EN 25 400V Motor CM 501 4kW 5 3 A CM 501 3 kW 4 1 A...