ENGLISH
38/39
3.- Use the “
SEL
” button to enter the desired value of the ± permissible temperature
deviation.
4.- Press the “
SEL
” push-button to store the new deviation value.
5.- Keep the “
SEL
” button pressed for 2 seconds to return to the temperature display mode. If it
is not held down, it will automatically return to the temperature display mode.
10.5.- Temperature controller default values
No.
Parameter name
Symbol
Display
Factory
default
Program
Locked
-
Set value
SV
-
0
70
40
6
Auto-tuning
At
oFF
L-oN
-
10
Set value of alarm 1
AL1
10
3
-
19
Key lock
LoC
0
0
5
30
Proportional band
P
5.0
13.9
-
31
Integral time
i
240
16
-
32
Derivative time
d
60.0
3.0
-
37
Anti-reset windup
AR
400
24.8
-
38
Control algorithm
CtRL
Pid
Pid2
-
39
PV
(Process Variable)
stable range
SLFb
8
1
-
41
Cycle time of control output 1
tC
2
1
-
43
Input signal code
P-N2
K
Pt
-
45
Upper limit of measuring range
P-SU
400
150
-
46
Decimal point position
P-dP
1
0
-
50
Time constant of input filter
P-dF
5.0
0.1
-
51
Alarm type 1
ALM1
0
11
-
91
SV
(Set value)
lower limiter
SV-L
0
20
-
92
SV
(Set value)
upper limiter
SV-H
400
70
-
126
Parameter mask
dSP1
0040
0077
00FF
127
dSP2
00E0
00E4
00E4
128
dSP3
dSP3
0060
00F0
00FE
129
dSP4
dSP4
002C
00A8
00FF
130
dSP5
dSP5
0014
009C
00FF
131
dSP6
dSP6
0001
00FF
00FF
132
dSP7
dSP7
0000
00FF
00FF
133
dSP8
dSP8
0000
00FF
00FF
134
dSP9
dSP9
0000
009F
00FF
135
dP10
dP10
004E
00FF
00FF
136
dP11
dP11
00bE
00FF
00FF
137
dP12
dP12
00FF
00FF
00FF
138
dP13
007F
007F
007F
139
dP14
0007
014F
017F
144
USER key + UP key
UKy2
1
0
-
145
USER key + DOWN key
UKy3
5
0
-
Summary of Contents for PACK 6000X
Page 2: ...ESPA OL an Elcometer company...
Page 24: ...ENGLISH an Elcometer company...
Page 46: ...PORTUGU S an Elcometer company...
Page 68: ...DEUTSCH an Elcometer company...
Page 90: ...FRAN AIS an Elcometer company...
Page 112: ...ITALIANO an Elcometer company...