background image

 
 
 

 
 

17 

 

IP65 PROTECTION RATING

 

The device is protected against  the  dust  penetration (first  digit  6) and against  jets of water 
(second digit 5). Suitable for outdoor use and fixed installation.

 

 

PROTECTION AGAIN ELECTRIC SHOCK

 

The device must be connected to a power supply system with efficient earthing. Moreover, it 
is recommended to protect power supply lines of the product from indirect contact and / or 
shorting to earth by using appropriately sized anti electrical shock switch.

 

 

CONNECTION TO THE MAINS

 

The electrical connection must be carried out by a qualified electrician.

 

Ensure that the mains frequency and voltage correspond to those for which the equipment is 
designed, as shown in the electrical data label. This label also shows the power consumption 
that is necessary to refer to evaluate the maximum number of devices to be connected to the 
electricity line, in order to avoid power overloading.

 

If the external power cord of this light  is damaged, it  must  be replaced with a  special cord 
exclusively available from Your PROEL dealer.

 

Never operate the equipment with lenses and / or covers missing or damaged.

 

In case of non-use, it is recommended to unplug the projector from the mains.

 

 

MAINTENANCE

 

Before  starting  any  maintenance  or  cleaning  the  product,  disconnect  the  power  from  the 
mains and disconnect the power cable from the device. After switching off, do not remove any 
part of the device for at least 35 minutes to avoid the risk of burns. The lenses, if damaged, 
must be replaced with original spare parts.

 

 

WARNING

 

CAUTION. Do not look directly at the light source. Do not look at the beam with lenses, glasses, 
mirrors  or  similar  optical  instruments  that  could  change  the  convergence  of  light,  causing 
serious damage to people and / or things.

 

 

 

WARNING! DANGER FOR THE EYES!

 

Do not look directly at the light source

 

 

Summary of Contents for SG IPLEDBAR24C

Page 1: ...IP LED Bar 24 RGBW FC SG IPLEDBAR24C MANUALE UTENTE USER MANUAL...

Page 2: ...INSTALLAZIONE ED ACCENSIONE p 7 5 ISTRUZIONI PER L USO p 9 6 MANUTENZIONE p 14 7 SPECIFICHE TECNICHE p 14 INDEX 1 INTRODUCTION p 15 2 SAFETY INSTRUCTIONS p 16 3 OPENING AND CONTROL p 18 4 INSTALLATIO...

Page 3: ...e di riciclarlo in maniera responsabile per favorire il riutilizzo sostenibile delle risorse materiali Gli utenti domestici sono invitati a contattare il rivenditore presso il quale stato acquistato i...

Page 4: ...di ancoraggio sia stabile prima di posizionare il prodotto Il cavo di sicurezza deve essere debitamente agganciato al dispositivo e fissato alla struttura di sostegno in modo che in caso di cedimento...

Page 5: ...mero massimo di dispositivi da collegare alla linea elettrica al fine di evitare sovraccarichi Se il cavo di alimentazione esterno di questa apparecchiatura da illuminazione danneggiato deve essere so...

Page 6: ...er la verifica ATTENZIONE Se l apparecchio stato esposto a drastici sbalzi di temperatura lasciare spenta l unit finch non raggiunge la temperatura ambiente in quanto la presenza di condensa potrebbe...

Page 7: ...L unit pu essere installata a pavimento in appoggio sugli appositi piedini a parete a soffitto o su truss ATTENZIONE E OBBLIGATORIO il montaggio della fune di sicurezza PLH232 PLH248 venduta separata...

Page 8: ...ttato come indicato nella targhetta dei dati elettrici 4 3 COLLEGAMENTO ALLA CATENA DMX Utilizzare un cavo conforme alle specifiche EIA RS 485 bipolare intrecciato schermato 120Ohm di impedenza caratt...

Page 9: ...i COLOR WW COLOR CW RED ORANGE YELLOW GREEN CYAN BLUE PURPLE COLOR SET RED 000 255 COLOR SET GREEN 000 255 COLOR SET BLUE 000 255 COLOR SET WHITE 000 255 Premere ENTER ed UP DOWN per selezionare uno d...

Page 10: ...SAVE impostazione custom che pu essere prima salvata e poi ricaricata Premere ENTER ed UP DOWN per selezionare la modalit TEMP INFO VALU xx C Valore rilevato di temperatura FIRMWARE V 1 02A Versione s...

Page 11: ...190 199 Effetto FLOW1 200 209 Effetto FLOW2 210 219 Effetto FLOW3 220 229 Effetto FLOW4 230 239 Effetto FLOW5 240 255 Effetto FLOW6 2 000 008 Nessuna funzione 009 255 Strobo da lento a veloce se CH1 0...

Page 12: ...Dimmer Rosso blocco 2 7 000 255 Dimmer Verde blocco 2 8 000 255 Dimmer Blu blocco 2 9 000 255 Dimmer Bianco blocco 2 10 000 255 Master dimmer blocco 2 Modalit 16 canali Canale Valore Funzione 1 000 2...

Page 13: ...immer Verde blocco 2 8 000 255 Dimmer Blu blocco 2 9 000 255 Dimmer Bianco blocco 2 10 000 255 Master dimmer blocco 2 11 000 255 Dimmer Rosso blocco 3 12 000 255 Dimmer Verde blocco 3 13 000 255 Dimme...

Page 14: ...azzola morbida o un panno per lenti per rimuovere la polvere depositata Le lenti come qualsiasi altra parte eventualmente danneggiata devono essere sostituite con ricambi originali 7 SPECIFICHE TECNIC...

Page 15: ...duct from other kinds of wastes and recycle it responsibly to promote the sustainable reuse of material resources Home users are encouraged to contact the retailer where they purchased this product or...

Page 16: ...nt is stable before positioning the product The safety cable must be properly attached to the device and fixed to the supporting structure so that in case of failure of the primary supporting system i...

Page 17: ...mber of devices to be connected to the electricity line in order to avoid power overloading If the external power cord of this light is damaged it must be replaced with a special cord exclusively avai...

Page 18: ...r verification WARNING If the product has been exposed to drastic temperature changes let the unit turned off until it reaches room temperature because the presence of condensation can damage the prod...

Page 19: ...ixing The unit can be installed on the floor resting on the rubber feet on the wall ceiling or on a truss WARNING IT S REQUIRED the mounting of the safety rope PLH232 PLH248 sold separately in the cas...

Page 20: ...the electrical data label 4 3 CONNECTION TO THE DMX CHAIN Use a cable conforming to specifications EIA RS 485 pole twisted shielded 120Ohm characteristic impedance and low capacity SAGITTER SG DMX3 S...

Page 21: ...OR CW RED ORANGE YELLOW GREEN CYAN BLUE PURPLE COLOR SET RED 000 255 COLOR SET GREEN 000 255 COLOR SET BLUE 000 255 COLOR SET WHITE 000 255 Press ENTER and UP DOWN to select one of fixed colors or to...

Page 22: ...SAVE user setting that can be saved and after reloaded Press ENTER and UP DOWN to set the specific mode TEMP INFO VALU xx C Value of temperature FIRMWARE V 1 02A Software version 5 2 MASTER SLAVE MODE...

Page 23: ...9 Effect FLOW2 210 219 Effect FLOW3 220 229 Effect FLOW4 230 239 Effect FLOW5 240 255 Effect FLOW6 2 000 008 No functions 009 255 Strobe from slow to fast if CH1 000 149 Speed from min to max if CH1 1...

Page 24: ...0 255 Dimmer Red block 2 7 000 255 Dimmer Green block 2 8 000 255 Dimmer Blue block 2 9 000 255 Dimmer White block 2 10 000 255 Master dimmer block 2 16 channels mode Channel Value Function 1 000 255...

Page 25: ...5 Dimmer Green block 2 8 000 255 Dimmer Blue block 2 9 000 255 Dimmer White block 2 10 000 255 Master dimmer block 2 11 000 255 Dimmer Red block 3 12 000 255 Dimmer Green block 3 13 000 255 Dimmer Blu...

Page 26: ...compressor and a soft brush or a lens cloth to remove the dust deposited The lenses like any other damaged part must be replaced with original spare parts 7 TECHNICAL SPECIFICATIONS Power Supply 100 2...

Page 27: ...27...

Page 28: ...Proel S p A Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 Mail info proel com Web www proel com...