MF 9841 SG-MEK1 17 – 2
a)
Push the sections indicated with
→
at the same time with
both hands.
* When handling the expansion memory, be careful not to
touch the pin section.
* Insert the memory straightly until it comes in contact
with the contact.
* When inserting, be careful not to slant the memory for
the connector. Do not push the memory by one hand
alone.
b)
Push the sections indicated with
→
at the same time with
both hands until the right and the left buttons are locked.
2)
Insert the power plug of the copier into the power outlet. Turn
ON the power switch.
D. Reattach the control PWB and the right rear
cabinet.
•
If the fax box unit is installed, carry out steps 1), 2), and 3)
additionally.
1)
Connect the interface cable to the control PWB unit.
2)
Push the interface cable into the recessed portion of the sheet
metal on the control PWB unit.
3)
Attach the snap band to the sheet metal of the control PWB
unit.
4)
Push the control PWB unit into the main unit.
5)
Secure the unit with the two screws.
•
If the fax box unit is installed, carry out step 6) addition-
ally.
6)
Fit the interface cable into the right rear cabinet cover.
7)
Attach the right rear cabinet cover to the main unit.
At this time, check that the four hooks are properly fitted to the
main unit.
8)
Secure the right rear cabinet with the screw.
9)
Attach the ozone filter cover to the main unit.
•
Reconnect the cables that have been removed in step B to
the original positions of the control PWB unit.
Hook 1 Hook 2
Hook 3
Hook 4
6
8
7