Operation in meter mode
Page 32 of 62
ZDUE-LTE-PLUS-VII
6.4.1
Parameter
The following table gives an overview of the additional parameter classes for
the IP telemetry mode. These classes are assigned numbers that must be
included in parameterisation commands.
Parameter
Class
Permitted access types
(R=Read/W=Write)
Provider classes
60, 61
R/W
IP Telemetry Client
Parameters
70, 76, 78
R/W
Writing parameters can only be done by writing a complete class.
Activation
In order for the ZDUE-LTE-PLUS-VII to operate in IP telemetry mode, the
parameter "String length IP destination address / host name" in parameter
class 70 must
not
be set to "00".
When parameterising with parameterisation software that sets the string
length automatically (such as the
ZDUEParametrierTool
), this is achieved
by writing the IP address of the Primary IPT Master into the ZDUE.