12. MAINTENANCE
12.1. OPERATING
THE
PORTABLE
IN CASE OF BATTERY FAILURE
A battery failure can be diagnosed in the following manner:
• Screen does not have any display;
• or battery icon appears crossed when you put the EFT930 on its base;
• or, even after a long battery recharging, the terminal autonomy is very limited.
It is necessary to change the battery.
If there is no battery, initialization of applications present in the equipment is still possible.
This is done by putting the terminal on its base. Nevertheless, it is not possible to carry
out transactions under these conditions.
12.2. CHANGING
THE
BATTERY
It is imperative to use a battery authorized by SAGEM Monetel.
There is danger of explosion if battery used is not approved by
SAGEM Monetel.
• Remove the portable from its base.
• Turn it off by pressing simultaneously the "Point" key and the "yellow" key during
about one second.
• Remove the cover of the battery housing (see § "Battery cover flap".
• Lift battery and remove it from its housing.
•
Carefully disconnect battery, following the
instructions below
.
a) Unlock the connector by pressing the locking
mechanism as indicated by F1 arrow while pulling
wires (arrow F2), so as to disconnect the connector.
Release traction on it as soon as the connector
comes unclipped.
b) Finish extracting connector by tilting it slightly
(arrow F3) so as to bring it away from the housing of
the terminal.
•
Inform the terminal that its battery has been changed. Do this by starting the terminal
without battery and fitting it on its base.
• Connect and install the new battery by following the instructions in § "Connecting the
Battery".
• Close the battery cover flap and charge the battery. See § "Charging the Battery".
• In order to preserve the environment, dispose of used batteries in compliance with
current recycling legislation in the country of use.
•
If the terminal is to be stored for a long time (more than two months), remove the
battery from the terminal.