137
Unless stated otherwise, all dimensions are given in mm.
MANTO®
12 Stopends
There are three ways to create stopends using the MANTO formwork system:
• For wall thicknesses up to 300 mm, use Outer Corner Clamps (code:448227, refer to
section 12.1) to create the stopend.
• For wall thicknesses 100 - 425 mm, use the PLATINUM 100 Bulkhead Clamp
(code:604328, refer to section 12.2) to create the stopend.
• For wall thicknesses > 425 mm, use the Multipurpose Waler 100 (code:450764, refer
to section 12.3) to create the stopend.
12.1 With Outer Corner Clamps
Up to 300 mm wall thickness
For wall thicknesses up to 300 mm, stopends can be created using the Outer Corner
Clamp (code:448227, refer to section ). The Outer Corner Clamps have to be attached
to the end panels and attached as shown below.
Dry tie
Outer Corner Clamp
(code:448227)
≤ 300
2700
Be aware that some sections are subjected to higher tensile loads (Refer to the table
below)!
Summary of Contents for Huennebeck MANTO G3
Page 1: ...MANTO Large frame panel formwork User guide...
Page 9: ...9 Unless stated otherwise all dimensions are given in mm MANTO...
Page 61: ...61 Unless stated otherwise all dimensions are given in mm MANTO MANTO G3 M MANTO G3 M...
Page 219: ...219 Unless stated otherwise all dimensions are given in mm MANTO...