LRF 3013 Integrator Manual
Document number: TML 913655 ver A
Public: 13.03.2017
Confidential & Proprietary
Safran Vectronix AG
– All rights reserved
page: 13/36
3. Insert a fully charged 9 V battery into the Universal Interface or connect to it an external
power supply. Safran Vectronix recommends the use of an external power supply of approx.
12V DC / 3 A. When battery operated, only a limited number of measurements are possible.
USB socket
– connection to PC
Connection to module (hard wired)
External power supply input
– recommended 12V DC
4. Connect the Universal Interface to your PC via RS232 or USB.
5. Connect the Universal Interface to your LRF Module
6
. Switch the Universal Interface on by pressing the “ON/OFF” button
. The status indicator
light
will illuminate, flashing approximately once per second showing that the LRF is being
powered. If the output voltage is not available, then the status indicator light will flash three
times per second.
The status indicator will also show the condition of the battery.
Green: battery voltage sufficient
Yellow: change battery
– only short working time left
Red: battery voltage insufficient
– output voltage to LRF will be disconnected
If the Error Indicator light
shows:
a. Red. The external power is polarity reversed
b. Yellow. External voltage is above 30V and too high. The Universal Interface will turn
off automatically
A complete troubleshooting guide can be found in the Universal Interface short guide
supplied in the LRF Interface kit.