QUICK START GUIDE
7
S
T
E
P
T
W
O
:
W
IR
IN
G
RS-232 PC Communication
Use CAT-5 UTP (or better) cable (shielded recommended).
Cable should be run in a direct (homerun) connection from the
unit to the PC’s DB9 COM port.
Ethernet
Ethernet connections to the device are made through a standard
RJ-45 connector on the back of the device. Use CAT-5 UTP (or
better) cable.
USB
Standard cable with Micro AB plug to A plug
(USB on the Go) is used.
Wiegand Output to Access Control Panel (ACP)
•
For 18 AWG, the maximum cable distance is 500 ft.
(150m); for 20 AWG, the maximum is 300 ft. (90m); for 22
AWG, the maximum is 200 ft. (60m).
•
Three-conductor wire (shielded recommended) is required for
Data 0, Data 1, and WGND.*
Power
For most installations, use 18-22 AWG cable.
Remember to calculate line-loss when selecting cable.
Wiring
(continued)
IMPORTANT:
1.
2.
* Morpho EAS always recommends the use of wiegand
Refer to local electrical codes and standards before selecting a cable type.
For UL-294 compliance, an earthed screen in the wire or around all wires to/from product is only
required when the wires share space/compartment/tube with high voltage cables