background image

SAFIRE 3200B AND 3800A FUEL OIL HEATER
INSTALLATION, OPERATION AND MAINTENANCE

1.5.1

30L TANK

 (475x315x295mm)

 

Can be used either upright or horizontally.
The heater comes with tank connection parts (filter, vacuum hose, air hose and 
threaded ring).

 

The tank must be placed under the heater, e.g. in the basement of the house.
If the fuel line and wiring of the pump have to be led through the structures, they
must be protected with e.g. electric plastic installation pipe. For trought the floor
or wall, drill approx. 10 mm hole for fuel line and wiring.

If you want to install the tank and pump inside, select a place where filling the 
tank or exchanging tanks does not cause inconvenience. 

1.5.3

TANK CONNECTION

1.5.4

PUMP

The pump is installed close to the tank above the liquid surface in an upright position with the 
suction side down. The maximum vertical drop from the bottom of the heater to the tank is 
approx. 2 metres.

  

 

1.6 

ELECTRICAL INSTALLATION 

(see wiring diagram on the back cover)

.  

 

1. The electricity should preferably be input directly from the battery (

+ red, - yellow

). Protect 

the wiring with a 20 A fuse (the electronics of the heater are protected by a 15 A main fuse).
If you need to use longer wires, remember to replace the original wiring with thicker ones so 
that the cross-sectional area of the wires in mm2 corresponds with the length of the wires in 
metres, e.g. the area of two 10 metre wires should be at least 10 mm2.

 

In this case, cut the original wires at a suitable length behind the heater and attach thicker 
wires with a suitable connecting piece.

 

Be careful not to

 connect the wires to the battery with reverse polarity (in this case, the 

fuse of the electronics will blow). 
2. The wires of the pump are connected to the middle pins of the X10 connector. The wires 
cannot be connected the wrong way round.
 

  

3. In thermostat installations the sensor is connected to the empty pins of the X10 connector 
(see wiring diagram). The wires can be extended and they cannot be connected the wrong 
way round.

4. A Gsm- remote start-up device is connected behind the control panel to the X9 connector of
the heater circuit board.
When using automatic start-up, the heater switch should be in the AUTO position.
The circuit board of the heater has a selection connector for the input voltage of the RJ 
connector. It should be in the position 2-3 when a 1287 remote control device is used (this is 
the factory default setting) and in position 1-2 if a Genius control board is used.

December 2014
SF-LÄMMITIN OY Tilhenkatu 1 20610 Turku Finland Tel./Fax 02-2443282

1. AIR HOSE
2. FUEL HOSE
3. THREADED RING
4. FILTER
5. PROTECTION

Summary of Contents for 3200B

Page 1: ... preferably be insulated with vermiculite This will avoid the condensation of the flue gas in the cold chimney as well as failures and weathering of the chimney resulting from the condensation 3 Install a piece of thermal insulation cut to a suitable length 4 Mount the heater and tighten the flue gas pipe and a potential air intake pipe with their fasteners 5 The combustion air can be led to the h...

Page 2: ...suitable length and fasten it with a clamp 12 5 Install the overlong flue gas pipe 5 with a fastener 6 6 Install thermal insulation 7 of suitable length around the flue gas pipe 7 Mount the heater 8 Remove the housing 10 and diffuser 9 from the frame of the funnel The housing can be removed by lifting its upper part approx 4 mm Attach the frame 8 of the funnel to the wall Seal with silicone compou...

Page 3: ...mber to replace the original wiring with thicker ones so that the cross sectional area of the wires in mm2 corresponds with the length of the wires in metres e g the area of two 10 metre wires should be at least 10 mm2 In this case cut the original wires at a suitable length behind the heater and attach thicker wires with a suitable connecting piece Be careful not to connect the wires to the batte...

Page 4: ... in a cold cabin for the winter it is recommended to run the heater with kerosene before leaving it unused so that the fuel pump and fuel lines remain filled with kerosene which withstands even colder temperatures 2 1 2 CONTROLS AND INDICATORS 2 1 2 1 CONTROLS The heater is started by turning the switch to the HEAT position The heater is started by turning the switch to the HEAT position Automatic...

Page 5: ...5 3 minutes after start up when the flame sensor has detected a sufficient combustion The ignition process ends after approx 6 5 minutes and the heater is set to the power level of the thermostat or manual setting 2 1 3 1 STARTING WITH A REMOTE START UP DEVICE When enabling the start up device make sure that the heater is ready for use and that air circulation is possible in the heated space Turn ...

Page 6: ...ing shown on the display Please note If you have turned off the heater after the malfunction was shown you can bring up the error code again by turning the switch to the AUTO position WHEN THE AUTO POSITION IS SELECTED THE DISPLAY SHOWS THE LAST ERROR CODE THAT HAS LED TO THE SHUTTING DOWN OF THE HEATER 3 3 ERROR MESSAGES in parentheses the text shown on GENIUS screens No 1 overheating fault indic...

Page 7: ...s paraffin formation which occurs when the fuel is in cold temperatures If the fuel line is not completely blocked the blockage can be removed by adding isopropanol to the fuel gasoline car antifreeze which dissolves the paraffin blockage rapidly Isopropanol can also be forced through the lines by using a syringe or e g a bicycle pump while the heater is on start up phase A small air leak in the s...

Page 8: ...en the burner compartment cover 3 screws force the top of the cover open from the protrusions 5 Remove the glow plug 1 and its mounting plate 6 Remove the burner support spring and the burner 8 If you are unable to remove the burner use a hammer and a suitable piece of wood see picture Remove the topmost centering plate of the spring 11 first in order to remove the burner cylinder without damaging...

Page 9: ...il wires 4 Remove the iron shell 1 of the pump by opening its screws 5 Pull the upper part 3 of the pump out of the coil 4 The piston 9 and spring 10 come loose at the same time 6 The lower end of the pump 5 can be removed by pulling as well 7 Now you can wash the insides of the pump with e g isopropanol There should not be any stiffness between the piston and the cylinder 8 Check the functioning ...

Page 10: ...INSPECTING AND CLEANING THE PUMP 4 4ELECTRICAL CONNECTIONS 3800A ...

Reviews: