background image

SAFIRE 3800A and 3200A and B HEATERS from No. 431 and up, and 2000A

3/2016

HEATERS from No. 281 and up 
INSTALLATION, OPERATION AND MAINTENANCE

Control functions:

 All functions are enabled when the heater is in AUTO position. All other functions, except for 

                 startup and shutdown, are enabled when the heater’s switch is in ON position.

 

Language selection: 

Send text message 

#KS

 in order to select Finnish (suomi).

                

Send text message 

#KR

 in order to select Swedish (svenska).

                

Send text message 

#KE

 in order to select English.

Commands:  

Commands are sent by using text messages. They are not case-sensitive, 

however, do not use spaces. Several commands can be sent in a single message. The order of the 
commands is up to you, but 

startup or shutdown commands must be first in command queues.

The heater is started with the message 

#nn

 (0-99 hours).

Example: The message #15 starts the heater for 15 hours. 

The message #0 shuts down a remotely started heater.

The message #R returns a report text message (battery voltage, temperature, heater status and remaining
heating time. The fuel quantity is also shown if a Genius control board is used.)

Please note!

 If a startup command is combined with a report command, the report is sent after the 

heater’s ignition process is completed (e.g. #12R).

The message 

#Tnn

 is used for setting a new temperature to the thermostat. The value must be 

between 10 and 30. 

Example: #T22 sets the thermostat expected value at 22 °C. This can be used for increasing or decreasing 
the set basic temperature.
The setting is removed when the temperature is adjusted from the heater.

The message 

#Pnumber

 is used for setting a phone number, which is used for sending reports and 

alerts. A plus sign must be entered before the number if it is international format. Example: 
#P+358401234567

The message 

#S

 sets the number stored in the memory slot 1 of the SIM card as the user’s phone 

number.

The message 

#H or h(+ or -) nn

 is used for setting the temperature alert threshold. Example: #-0,5

sets the temperature alert at -0.5°C. The alert can be disabled by setting the alert threshold at -50 °C. An
exclamation mark (!) instead of a colon (:) after the text SAFIRE indicates that the alert is set.

Power saving mode:

 The heater’s software is factory-preset to save power: the modem checks for text messages 

every hour. This leads to reduced power consumption (November-January). When the heater’s switch is in AUTO position,
the modem is on for approx. 10 minutes, during which a successful connection is indicated by a red indicator blinking 
sporadically.

For example, if you want instant reports, you can turn off the power saving mode by sending a text 

message containing 

#V0

.

The power saving mode is switched on with the command 

#V1

.

(Note! When using the Genius control panel, the power saving mode is enabled and disabled from 

the control panel, not by sending a text message.)

Notifications:

The device sends messages and alerts to the number from which it has received the 

previous command. When the device is switched off, it forgets the phone numbers. When the switch is turned to the AUTO
position, e.g. low voltage alerts are sent to the number in memory slot 1 of the SIM card. 

The command #S can be used for sending all messages to the number in memory slot 1 instead of using the

number used to send a command.

If there is an error in the text message, a description of the error is sent to the sender, except for if the 

pound sign (#) is missing from the beginning of the message, in which case the device does not reply.

Alerts:

The device sends an alert if the voltage of the battery system drops below 12 V.
If the heater shuts down due to an error after it has been turned on by a mobile phone, the device sends a 

text message with a fault code for identifying the fault. The heater cannot be restarted with a text message until the cause of
the error is eliminated and the heater is reset to GSM control, 

unless it is the lack of flame fault (error code 3) in which 

case a restart is possible.

 

The device will alert if the temperature drops below a threshold, if it has been set.

Manufacturer’s declaration: 

Elekno Oy assures that the Safire 1287B GSM control device complies with 

the essential requirements and other conditions of directive 1999/5/EC.

SF-Lämmitin Oy Tilhenkatu 1 20610 TURKU

Tel/Fax 02-2443282 e-mail [email protected]

Reviews: