SafeWaze FS-EX325 Instruction Manual Download Page 11

V1.0 2018 Copyright SAFEWAZE™

Page 11

Unless explicitly stated otherwise, the maximum allowable free fall distance for lanyards must not 

exceed 6’.  Class A SRLs must arrest falls within 24”; Class B SRLs must arrest falls within 54”.

Harnesses and connectors selected must be compliant with manufacturer’s instructions, and must be 

of compatible size and configuration. Snap hooks, carabiners, and other connectors must be 

selected and applied in a compatible fashion. All risk of disengagement must be eliminated. All snap 

hooks and carabiners must be self-locking and self-closing, and must never be connected to each 

other.

A pre-planned rescue procedure is required in the event a fall occurs. The rescue plan must be 

project-specific. The rescue plan must allow for employees to rescue themselves, or provide an 

alternative means for their prompt rescue. Store rescue equipment in an easily accessible and clearly 

marked area.

Training of Authorized Persons to correctly erect, inspect, disassemble, maintain, store, and use 

equipment must be provided by a Competent Person. Training must include the ability to recognize 

fall hazards, minimize the likelihood of fall hazards, and the correct use of personal fall arrest 

systems.

NEVER use fall protection equipment of any kind to hang, lift, support, or hoist tools or equipment, 

unless explicitly certified for such use.

Equipment subjected to forces of fall arrest must immediately be removed from use.

Age, fitness, and health conditions can seriously affect the worker should a fall occur. Consult a 

doctor if there is any reason to doubt a user’s ability to withstand and safely absorb fall arrest forces 

or perform set-up of equipment. Pregnant women and minors must not use this equipment.

Physical harm may still occur even if fall safety equipment functions correctly. Sustained post-fall 

suspension may result in serious injury or death. Use trauma relief straps to reduce the effects of 

suspension trauma.

Labels

J

F

M

A

M

J

J

A

S

O

N

D

INSPECTION

322 Industrial Court, Concord, NC 28025

(704) 262-7893  |  www.safewaze.com

FS-EX325

12 IN DECK ANCHOR for WOOD, CONCRETE, and STEEL

Must follow all manufacturer’s instructions included with the equipment at the time of shipment.

Meets: OSHA 1910 & OSHA 1926 Subpart M; ANZI Z359.1 & ANSI A10.32

01165R1

MATERIALS: Galvanized steel
WEIGHT CAPACITY RANGE: 130-310 lbs, or up to 420 lbs if used with equipment explicity certified for such use.
Maximum 1 connection per anchor.
Only make compatible connections.
Refer to instructions for proper installation and connection methods.
All PFAS equipment must be selected and deemed compatible with with this anchor by a Competent Person.
Avoid contact with hazards, including (but not limited to) heat chemicals, electricity, and sharp or abrasive edges and surfaces.
Product lifetime is indefinite, so long as the equipment passes pre-use and Competent Person inspections.
This unit must be inspected prior to each use.
A Competent Person must complete a formal inspection of this unit every 6 mos.
If equipment fails inspection, IMMEDIATELY REMOVE THE UNIT FROM SERVICE.
Do not remove label.

MFG. DATE

XX/XX

J

F

M

A

M

J

J

A

S

O

N

D

INSPECTION

322 Industrial Court, Concord, NC 28025

(704) 262-7893  |  www.safewaze.com

FS-EX326

18 IN DECK ANCHOR for WOOD, CONCRETE, and STEEL

Must follow all manufacturer’s instructions included with the equipment at the time of shipment.

Meets: OSHA 1910 & OSHA 1926 Subpart M; ANZI Z359.1 & ANSI A10.32

01165R2

MATERIALS: Galvanized steel
WEIGHT CAPACITY RANGE: 130-310 lbs, or up to 420 lbs if used with equipment explicity certified for such use.
Maximum 1 connection per anchor.
Only make compatible connections.
Refer to instructions for proper installation and connection methods.
All PFAS equipment must be selected and deemed compatible with with this anchor by a Competent Person.
Avoid contact with hazards, including (but not limited to) heat chemicals, electricity, and sharp or abrasive edges and surfaces.
Product lifetime is indefinite, so long as the equipment passes pre-use and Competent Person inspections.
This unit must be inspected prior to each use.
A Competent Person must complete a formal inspection of this unit every 6 mos.
If equipment fails inspection, IMMEDIATELY REMOVE THE UNIT FROM SERVICE.
Do not remove label.

MFG. DATE

XX/XX

Summary of Contents for FS-EX325

Page 1: ...ns before using this equipment Manufacturer s instructions must be followed for proper use and maintenance of this equipment Alterations to this product misuse of this product or failure to follow ins...

Page 2: ...G CONNECTIONS 6 7 COMPONENTS AND SPECIFICATIONS 7 8 PRODUCT APPLICATIONS 7 9 INSTALLATION AND USE 8 9 10 INSPECTION 9 10 11 SAFETY INFORMATION 10 12 LABELS 11 Do not throw away these instructions Read...

Page 3: ...he governing of occupational safety regarding Personal Fall Arrest Systems PFAS Worker Classifications Understand the definitions of those who work in proximity of or may be exposed to fall hazards Qu...

Page 4: ...before the user strikes the ground or an obstruction When calculating fall clearance account for a MINIMUM 2 safety factor deceleration distance user height length of lanyard SRL and all other applica...

Page 5: ...ystem components see Figure 4 Do not use equipment that is not compatible Non compatible connectors may unintentionally disengage see Figure 3 Connectors must be compatible in size shape and strength...

Page 6: ...complies with ANSI Z359 1 2007 or ANSI Z359 12 and is equipped with a 3 600 lb 16 kN gate Check the marking on your snap hook to verify its compatibility NOTE Large throat snap hooks must not be conn...

Page 7: ...event workers from reaching the leading edge or edge of a fall hazard If used in Fall Restraint applications the user must always account for fully deployed length of lanyard or SRL The structure to w...

Page 8: ...trate for Wood Installation is 5 8 CDX Wood Installation requires 40 14 10 2 screws for wood decking To install place FS EX325 FS EX26 Anchor Post in desired installation location and install ALL fast...

Page 9: ...installation Inspection User must inspect the FS EX325 FS EX326 prior to each use for damage or deficiencies including but not limited to cracking rust corrosion deformation alteration sharp edges da...

Page 10: ...se equipment Workplace conditions including but not limited to flame corrosive chemicals electrical shock sharp objects machinery abrasive substances weather conditions and uneven surfaces must be ass...

Page 11: ...893 www safewaze com FS EX325 12 IN DECK ANCHOR for WOOD CONCRETE and STEEL Must follow all manufacturer s instructions included with the equipment at the time of shipment Meets OSHA 1910 OSHA 1926 Su...

Page 12: ...SAFEWAZE 322 Industrail Court Concord NC 28025 PHONE 1 704 262 7893 FAX 1 704 262 9051 EMAIL info safewaze com Web safewaze com V1 0 2018 Copyright SAFEWAZE Page 12...

Reviews: