background image

  

322 Industrial Court, Concord NC, 28025

  

Phone: 704-262-7893

  

Email: [email protected]

  

Web: safewaze.com

 

 Fax: 704-262-9051

I

I

I

I

I

INSTALLATION

INSTALLATION EXAMPLE

WARNING

 

    

   

•  Users should consult with their doctor to verify ability to safely absorb the forces of a fall arrest event.  

Fitness level, age, and other health conditions can greatly affect an individuals ability to withstand fall 

arrest forces. Women who are pregnant, individuals considered minors must not use any SAFEWAZE™ 

equipment. 

•  Never alter any part of a anchor or add/remove components.  SAFEWAZE™ shall not be held 

responsible for injury or death due to tampering.

•  Anchors that are exposed to fall arrest forces MUST be IMMEDIATELY removed from service and 

destroyed.  

•  Failure to follow these instructions and warnings could result in serious injury or death in the event 

of a fall.

•  A preplanned rescue procedure in the event of a fall is required.  The rescue plan must be specific to 

the project.  The rescue plan must allow for employees to rescue themselves, or to be promptly rescued 

by alternative means. 

•  Harnesses or connectors selected for use with any SAFEWAZE™ anchor must be compatible in size 

and configuration. User must ensure compatibility of snap hooks, carabiners and other connectors.  Any 

connection which could allow disengagement must be eliminated. Snap hooks and carabiners must be 

self locking and self closing and must never be hooked to each other. 

•  A Competent Person must conduct an analysis of the workplace and anticipate where workers will be 

conducting their duties, the route they will take to reach their work, and the existing and potential fall 

hazards they may be exposed to.  The Competent Person must choose the fall protection equipment 

to be utilized.  

•  Do not misuse equipment.

•  Equipment designated for fall protection must never be used to lift, hang, support or hoist tools or 

equipment unless specifically certified for such use.    

•  SAFEWAZE™  Anchors shall be inspected prior to each use by the user and at least every 12 months 

by a Competent Person.  Annual inspections shall be documented.  Severity of conditions during use 

may neccesitate increased frequency of documented inspections.  

•  Anchors that fail inspection MUST be removed from service.

•  Prior to each use, inspect the 019-4006 Roof Anchor for deficiencies or damage, including, but not 

limited to, sharp edges, rough edges, deformations, corrosion, pits, burrs, chemical exposure, extreme 

heat exposure, or missing or illegible labels. If any deficiencies or defects are found, the 019-4006 must 

IMMEDIATELY be removed from service.

•  The 019-4006 Roof Anchor must be inspected at least every 12 months by a Competent Person other 

than the user.  Competent person inspections must be recorded in the inspection log included in this 

manual and on the inspection grid label on the 019-4006. 

•  The 019-4006 Roof Anchor has two energy absorbing regions and two stabilizing joins which hold the 

eyelet in place during use.  If these energy absorbing regions are expanded / deformed, this will indicate 

that the anchor has arrested a fall.  Additionally, if either of the two stabilizing joins are broken, this would 

also indicate that the 019-4006 has arrested a fall. 

•  The eyelet on the 019-4006 should be straight and inline with the anchor and the fall of the roof.  If the 

eyelet is distorted or deformed, this will indicate that the 019-4006 has arrested a fall. 

•  Visually inspect the water repellent membrane on the underside of the 019-4006 to ensure it is not 

torn, damaged, and has remained in place.

INSPECTION

MAINTENANCE & STORAGE

WARRANTY

The 019-4006 Roof Anchor can be cleaned with water and mild soap if necessary.  User should remove 

all dirt, possible corrosives, and contaminants from the anchor prior to, and after each use.  Never use 

any type of corrosive substance to clean the 019-4006.  

Excess water should be blown out with compressed air.  Hardware can be wiped off with a clean, dry 

cloth.

When not in use, store the 019-4006 Permanent Roof Anchor in a cool dry area where it will not be 

exposed to extreme light, extreme heat, excessive moisture, or possibly corrosive chemicals or 

materials.   

SAFEWAZE™ warrants its products are free from defects in materials and construction under normal 

use and service.  Liability is not accepted for abuse, modification, improper use, destructive activity and 

contaminated exposure. 

INSPECTION LOG

Date

Inspection Items 

Noted

Corrective Action

Initials

LABELS

1. Under guidance of a Competent or Qualified Person, a suitable anchor point must be chosen that 

meets the strength requirement, minimizes free fall, and reduces swing fall hazards. Do not work above 

the anchorage point.

2. The 019-4006 Roof Anchor can be installed on any structure that meets the strength requirements as 

defined in the SPECIFIC ANCHOR APPLICATIONS section of this manual for Personal Fall Arrest.

3. The 019-4006 Roof Anchor should be installed parallel with the roof sheets.  It is recommended the 

019-4006 be installed on the high section of the roofing panel aligned with the fall of the 

roof. (See Figure 6)  The 019-4006 can be installed into the pan of the roofing panels, but user should 

ensure that an area where debris or leaves can collect is not created. 

4. Drill (7) x 8 mm holes into the roof sheets through the pre-drilled holes on the 019-4006.

5. Secure the 019-4006 Roof anchor to the roof by riveting through the holes in the 019-4006 and the 

roof sheet using the supplied 8 mm rivets. Minimum metal thickness required is 25 gauge (.455 mm)

6. The 019-4006 is best suited for use on roof pitches up to 30°.  For roof pitches greater than 30°, the 

019-4006 should be used in conjunction with other access methods to ensure there is no live loading of 

the anchor.  The 019-4006 are not designed for rappelling or lifting operations. Exposure of the 

019-4006 to a live load could trigger the energy absorbing regions. 

7. The 019-4006 is suitable for use with Horizontal Lifeline Systems. 

8. The 019-4006 Roof Anchor can be removed and re-used unless the anchor is damaged or has 

experienced Fall Arrest Forces.  If either of these conditions exist, the anchor must IMMEDIATELY 

removed from service and destroyed.   

9. The 019-4006 is designed as a fall arrest anchorage for a single user with a maximum weight capacity 

of 310 lbs. including tools and equipment. If two 019-4006 Roof Anchors are used for installation of a 

Horizontal Lifeline System, the system can accomodate up to two users. 

10. The allowable working radius of the 019-4006 Roof Anchor is 360°. The 019-4006 is 

Multi-Directional, and will arrest a fall from any direction relative to the anchor. (See Figure 8) 

FIGURE 7 - INSTALLATION

FIGURE 8 - ALLOWABLE WORK RADIUS

INSTALLATION EXAMPLE

FIGURE 6 - INSTALLATION

FIGURE 6 - OVERHEAD VIEW

FIGURE 6 - CUT AWAY VIEW

•  

If installing the 019-4006 Roof Anchor on a clip down style metal roof, the anchor must not be installed 

any closer than 6.55 ft (2 m) from an edge unless addtional securing of the roof sheeting is made. 

•  Additional securing of the roof sheets can be made with 12 gauge roofing screws through the roof 

sheeting into the purlin / batten.  Four 12 gauge roofing screws should be fastened above the anchor, 

and four installed below the anchor. This secures the roof sheeting in place to the purlins / battens, and 

prevents horizontal movement in the event of a fall. (See Figure 7)

8 mm Rivets

Purlin

Purlin

12 Gauge Roofing Screws

12 Gauge Roofing Screws

360°

Part# 019-4006

Permanent / Temporary Roof Anchor

Min. Break Strength: 5,000 lbs

Materials: Stainless Steel

Capacity: 130-310 lbs including clothing, tools, etc.

OSHA 1926.502

Manufacture Date:  XX/XX

Serial #:  XXXXXXX

800-230-0319

DO NO

T REMO

VE L

ABEL

J

D

N

O

S

A

J

J

M

A

M

F

WARNING

                       ! THIS EQUIPMENT IS DESIGNED FOR USE AS A FALL

PROTECTION ANCHOR. USER MUST READ AND FOLLOW INSTRUCTIONS

SUPPLIED WITH THIS PRODUCT AT TIME OF SHIPMENT. FAILURE TO DO SO 

MAY RESULT IN SERIOUS INJURY OR DEATH. AVOID CONTACT WITH 

HAZARDS INCLUDING BUT NOT LIMITED TO, HEAT, CHEMICALS, 

ELECTRICITY, AND SHARP OR ABRASIVE EDGES AND SURFACES. MAKE 

ONLY COMPATIBLE CONNECTIONS. REFER TO INSTRUCTIONS FOR 

APPROPRIATE INSTALLATION AND CONNECTION METHODS.

USER MUST INSPECT BEFORE EACH USE.  COMPETENT PERSON 

MUST INSPECT AT LEAST ONCE EVERY 12 MONTHS AND PUNCH 

CORRESPONDING MONTH/YEAR ON INSPECTION GRID. 

IF UNIT FAILS INSPECTION 

REMOVE FROM SERVICE

0415a

U

P

U

P

TYPICAL USAGE EXAMPLES

Reviews: