7
3.2.2 Clamps
For certain roof sheet profiles the X-Rail may be installed with the below clamps.
Figure 10
CLAMPS
ROOF SHEET
INSTALL TORQUE
(MAIN)
INSTALL TORQUE
(SIDE) IF APP
S5 Z
KingZip400
40Nm
16Nm
3.3
Fasteners
All X-Rail Fasteners are M10 socket head cap screws. All fasteners shall be tightened to 40Nm
with a 6mm hex wrench.
⚠
All bolt threads must be applied with Loctite 243 thread-locker or equivalent prior to
assembly. (IMPORTANT NOTE: Before applying Loctite 243 use Loctite 7471 primer or
equivalent to activate the surface according to manufacturer’s instructions).
4
System Assembly
4.3.1 System Termination / Shuttle Stop
At the end of a system or at a point where it is necessary to prevent the passage of a shuttle,
a shuttle stop shall be installed. Drill an 11mm diameter hole in the centre of the rail, through
the top surface only. Where the rail terminates an end cap should be fitted.
Figure 11
1
2
STEP 1
STEP 2
COMPLETE SYSTEM TERMINATION AND STOP