Valve programming 

 

 

Step  Action 

Selections 

Next Action 

Press SET & 

 

To Set “P” setting for filters (hold for 3-5 seconds) 

 

Press SET & 

 

Press again

 

(hold for 3-5 seconds) 

Press SET 

Set “P” setting 

Arrow up or down to the Program (P) setting desired: 

 

 

 

P = 8 for carbon or sediment (10 mins. backwash; 6 mins. rinse) 

Press SET 

 

 

P = 9 for Iron, Sulfur, Neutralizer (14 mins. backwash; 8 mins. rinse) 

Press SET 

99 

Display shows “99” (does not apply) 

Press SET 

dP 

Display shows dP (does not apply) 

Press SET 

12 Hr  

Do nothing and . . . 

Press SET 

Back at time 

Now, set regen time: 

 

Press set & 

 

Hour is blinking. Arrow up or down to hour desired.  (12 AM typical.)  Press SET 

 

Minutes blinking.  Arrow up or down to minutes desired 

Press SET 

10 

 

Now set regen days.  (Filters typically regen every 3 to 5 days) 

Press SET 

Note  

 

 

 

 

 

Press and release to regen tonight 

 

 

 

Press and hold to regen immediately.  To advance cycles press 

 

Back to time. 

Note:  Clock for the filter valve is a 12 hour clock.  Note arrows on the face plate. Arrow pointing to “time” is AM.  Arrow pointing to “PM” is PM. 

 

Start-Up 

With the valve’s inlet and outlet closed, initiate a manual regeneration and follow these directions: 
 

1.

 

Press   

  

 together and hold buttons for 3-5 seconds to go into an immediate regen. 

2.

 

Let the valve advance to BACKWASH. 

3.

 

Open valve’s inlet slowly 1/3 to fill mineral tank. 

4.

 

Allow air to escape (listen until spurting stops). 

5.

 

When water flows from drain, open inlet valve fully.   

6.

 

Make sure drain line is not restricted.  Continue backwash until water runs clear. 

7.

 

Press arrow 

DOWN

 to advance to service. 

 

Finally . . . 

 

1.

 

Open the valve’s outlet to supply water to the house. 

2.

 

Open a faucet to see if water runs clear.   

3.

 

Shut off faucet.  

 

 

Customer orientation 

It is important to provide customers with an initial orientation.  This should include how to reset the clock and 
how the backwashing process works.  

 

Caution 

Do not fill swimming pools with water from an Iron / sulfur filter.  This will exceed the capacity of the system. 

 

Warranty 

Signature Series Safety Zone Water Systems come with a limited warranty.  Five years for valves, and ten years 
for tanks.  Activated carbon and filter media come with a quality guarantee only.  See warranty card or go to 

www.safetyzonewater.com

 for full details. 

Summary of Contents for WHF-100-A

Page 1: ...e 12 V AC Filtration media Catalytic activated carbon Additional treatment KDF 55 filter cubes By pass valve Included Specifications Safety Zone Whole House Filters Automatic models come with our Signature Series filter valve to backwash the carbon or filter bed routinely Our budget priced non electric models eliminate the need for a drain and reduce installation costs To view our valve manuals vi...

Page 2: ...is will start you up in backwash 7 Open the inlet slowly Once water runs to drain open the inlet fully 8 Continue backwash until the drain water runs clear This may take some time Press arrow DOWN to advance to service 9 When the valve goes into service open outlet on the valve to supply water to the house Valve Programming Safety Zone Water Signature Series filter valve The Safety Zone Signature ...

Page 3: ...ts to time this is AM If arrow points to PM this is PM Note If arrow is blinking on REGEN this means unit will regen tonight Automatic filter drain installation Carbon Iron sediment filters and acid neutralizers A drain is needed with automatic backwashing filters Use or 1 rigid PVC pipe or drain line tubing If tubing is used be sure to use the tube insert and drain line nut provided to secure the...

Page 4: ...inting to PM is PM Start Up With the valve s inlet and outlet closed initiate a manual regeneration and follow these directions 1 Press together and hold buttons for 3 5 seconds to go into an immediate regen 2 Let the valve advance to BACKWASH 3 Open valve s inlet slowly 1 3 to fill mineral tank 4 Allow air to escape listen until spurting stops 5 When water flows from drain open inlet valve fully ...

Reviews: