background image

Safetrust Inc. | 

safetrust.com

[email protected]

FCC:

  This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is

subject  to  the  following  two  conditions:  (1)  This  device  may  not  cause
harmful  interference,  and  (2)  this  device  must  accept  any  interference
received, including interference that may cause undesired operation. 

Canada  Radio  Certification: 

This  device  complies  with  Industry  Canada

license-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device
must  accept  any  interference,  including  interference  that  may  cause
undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables
aux  appareils  radio  exempts  de  licence.  L’exploitation  est  autorisée  aux
deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage,
et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique
subi,  même  si  le  brouillage  est  susceptible  d’en  compromettre  le
fonctionnement.

CE Marking:

 Safetrust hereby declares that these proximity readers are in

compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC.

Summary of Contents for 8845-100

Page 1: ...8845 100 Quickstart Guide Last Updated July 2022 ...

Page 2: ...Contents Safetrust Inc safetrust com sales safetrust com In the box What you ll need Installation Configuration Testing Regulatory Support 01 02 03 04 05 06 07 ...

Page 3: ...01 Safetrust Inc safetrust com sales safetrust com In the box ...

Page 4: ... 2X6MM BLUE ZINC CR3 For mounting to wall Nylon wall plugs Used to brace the screws inside the wall 6 32 x 375 phillips flat head screw Option 2 Secures the top and bottom casing together Optical tamper reflective post Adhered to the surface where the sensor is being mounted ...

Page 5: ...by trimming the template along the thicker dotted line being mindful not to cut the other dotted lines in the diagram Then tape the template to the installation site ensuring you remove the cut out piece from the template where the reflective tamper post will be mounted The diagram in this document is not to scale and cannot be substitued for the official mounting template ...

Page 6: ...02 Safetrust Inc safetrust com sales safetrust com What you ll need ...

Page 7: ...ctor Wiegand 4 conductor Twisted Pair Over All Shield and UL approved Belden3107A or equivalent OSDP Linear DC power supply Metal or plastic junction box Drill with various bits for mounting hardware Safetrust Inc safetrust com sales safetrust com ...

Page 8: ...03 Safetrust Inc safetrust com sales safetrust com Installation ...

Page 9: ...wall mounted installation begin by pre drilling your holes and insert the nylon screw plugs provided to support the weight of the reader Once secured to the wall you can fix the black plate to the wall using the screws SCR PTP 2X6MM BLUE ZINC CR3 provided ...

Page 10: ...t the wires as per the wiring table above Ground Relay In Relay Out Red LED Tamper Green LED Wiegand D0 Data Wiegand D1 Clock F2F 12VDC OSDP TX RS 485 A D0 OSDP TX RS 485 B D1 Beeper Black Grey Blue Brown Purple Orange Green White Red Aqua Pink Yellow Wire Colors Low voltage ...

Page 11: ...Safetrust Inc safetrust com sales safetrust com Once the back plate has been fitted and the wiring is complete the top casing can be inserted onto the bottom casing like shown above ...

Page 12: ...Safetrust Inc safetrust com sales safetrust com Complete the hardware installation by fixing either the snake eye screw SMF 6 32X5 16 SS or a Phillips screw SMF 6 32X5 16 SS to bottom casing ...

Page 13: ...04 Safetrust Inc safetrust com sales safetrust com Configuration ...

Page 14: ...Safetrust Inc safetrust com sales safetrust com Open the Safetrust Wallet APP and select Manage Sensor tab Make sure your system admin has set you up with this role ...

Page 15: ...Safetrust Inc safetrust com sales safetrust com With the Admin Installer tab open from the App bring the phone in range of the IoT Sensor and once visible from the App highlight and select Configure ...

Page 16: ...es safetrust com Choose an Identity System Specify the Type of access from the dropdown eg Door Gate etc Assign a short Name and Description using alphanumeric characters Choose an Output for the sensor the default is set to Wiegand ...

Page 17: ...m sales safetrust com When the IoT Sensor information is saved successfully to Credential Manager and assigned to the Identity System the new description will appear in the Manage Sensor tab with a unique serial number assigned ...

Page 18: ...05 Safetrust Inc safetrust com sales safetrust com Testing ...

Page 19: ...st Inc safetrust com sales safetrust com LED Ring Status LED Solid red Indicates idle mode Flashing red Powering up Solid green Success Flashing green Credential is read and access is granted Access with cards ...

Page 20: ...st Inc safetrust com sales safetrust com LED Ring Status LED Solid red Indicates idle mode Flashing red Powering up Solid Blue Success Flashing Blue Credential is read and access is granted Access with mobile ...

Page 21: ...06 Safetrust Inc safetrust com sales safetrust com Regulatory Information ...

Page 22: ...y not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit ...

Page 23: ... com sales safetrust com Support Thank you for purchasing the Safetrust IoT Sensor Mullion If for any reason you need assistance with your installation please contact your local Sales representative Sincerely The Safetrust Team ...

Page 24: ...www safetrust com support ...

Reviews: