4 of 8
Document No.: SIG-00-01-17
Version: C
NOTE
A 5001 error message may appear within the
alphanumeric display while downloading the data
recorder software. This error message should be
ignored.
Step 8
Set the MS/GCP
POWER
switch to
OFF.
Step 8.1
Set the Recorder Module
CLEAR/OFF/PRINT
toggle switch to the
CLEAR
position
and hold, then set the MS/GCP
POWER
switch to
ON.
Step 8.2
Continue to hold the
CLEAR/OFF/PRINT
toggle switch in the
CLEAR
position until
a
Downloading
window appears briefly within the Setup screen (see figure 4).
Figure 4.
Boot Program Downloading Window
115f4.tif
10-12-01
115f2.tif
10-12-01
Figure 3.
Data Recorder Module Software Installation Setup Screen