CHECKING LIFT HEIGHT
16
1. On the PinBrazing unit Econect, press and hold
“SETTING” and press ”ON/OFF”.
When “LOW BATTERY” is lit, release buttons.
Press “SETTING” and the leds will start to blink.
In this mode it is able to check the lift height.
2. Insert the brass part of the tool in the pin holder and fit
the plastic part in to the ring holder.
3. Press the trigger on the gun and watch the brass rod.
IMPORTANT!
Press the tool completely against the gun when
triggering the gun. Otherwise the gun may
be damaged!
IMPORTANT!
Hold the gun so the tool is horizontal.
4. The lift level is calibrated when the brass rod is in
same level as the outer plastic sleeve.
Tolerance ±0,2 mm.
If the brass rod stick out more than 0,2 mm, then the gun
needs to be calibrated, see point 4 on the next page.
If the brass rod goes in more than 0,2 mm, then the gun
needs to be calibrated, see point 5 on the next page.
See next page (17) for instructions on how to calibrate the
PinBrazing gun S15.
The normal lift height is 2 mm. This is very important for the arc and energy amount.
Too high lift height increase the risk of a “cold brazing”, too low lift height reduce the
time and increase misfires.
IMPORTANT
Lift level tool
: SAFE 91245